Relay packs SC3500E5045 are used in conjunction with the 8000 and 7000 series SER8300 and SER7300 Room Controllers for Low or Line Voltage 2 or 4 pipes Fan Coil applications. The relay packs are specifically used for other applications such as reheat valves, fan coil, chiller, or heat or cool valve control. The relays rated supply voltage is 7V DC +/- 10% or 90 to 277V AC at 50 or 60Hz. The maximum output current for cool valve is 5A, for heat valve 10A, and for fan relay (< 0.5 hp) is 13A at < 277V AC The load type can be either Motor or Fan or Valve at a voltage of 90 to 277V AC at 50 or 60 Hz. The relay pack has 3 outputs for fan relays and 2 outputs for valve relays. The relay package follows the following directives: 2004/108/EC - electromagnetic compatibility, 2006/95/EC - low voltage directive, and 1999/5/EC - R&TTE directive. The relay pack is certified for the following standards: FCC part 15 subpart B, ICES-003, UL 873, CSA C22.2 No 24, IEC 61326-1 - 2005, EN 60730-2-9, UL 61010-1 - ed. 3, IEC 61010-1 - ed. 3, CSC 61010-1 - ed. 3. The ambient air temperature for operation is between 32 and 122 oF. The ambient air temperature for storage is between -22 and 122 oF. The relative humidity for operating or storage is between 0 and 95% non condensing.
Device short name
SC3000
Width
80.01 mm
Product or component type
Relay pack
Network frequency
50 Hz 60 Hz
Device application
Low voltage fan coil
Directives
1999/5/EC - R&TTE directive 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive
Net weight
0.34 kg
Depth
33.02 mm
Ambient air temperature for operation
-0…50 °C
height
121.92 mm
Ambient air temperature for storage
-30…50 °C
Number of outputs
3 fan relay 2 valve relay
Standards
IEC 61326-1:2005 FCC part 15 Subpart B ICES-003 UL 873 EN 60730-2-9 UL 61010-1:ed. 3 IEC 61010-1:ed. 3 CSC 61010-1:ed. 3 CSA C22.2 No 24
Range
EcoStruxure Building Expert
Product specific application
3-stage speed Control of reheat valve Control of heat/cool valve Control of chiller Control of fan coil
Maximum output current
For fan relay: 13 A at <= 277 V AC and 0.5 hp, brown/blue/red wire For cool valve: 5 A at <= 277 V AC, yellow wire For heat valve: 10 A at <= 277 V AC, orange wire
Range compatibility
EcoStruxure Building Expert communication card EcoStruxure Building Expert SE7000 Series SER7300 room controller EcoStruxure Building Expert SE8000 Series SER8300 room controller
Load type
Motor - 90...277 V AC at 50/60 Hz Fan - 90...277 V AC at 50/60 Hz Valve - 90...277 V AC at 50/60 Hz
Connections - terminals
Screw terminal AWG 22...AWG 14
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.4 cm
Package 1 Width
7.9 cm
Package 1 Length
12.2 cm
Package 1 Weight
340 g
Unit Type of Package 2
CAR
Number of Units in Package 2
1
Package 2 Height
5 cm
Package 2 Width
11 cm
Package 2 Length
15.5 cm
Package 2 Weight
0.34 kg
Unit Type of Package 3
S02
Number of Units in Package 3
20
Package 3 Height
15 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
6.8 kg
Warranty
18 months
Datasheet