LV481000

MONITORING RELAY RHUs 110V/130 V

Trade Price

£513.61

Per

1

Unit

EA

Pack Quantity

1

LV481000

Information

VigiPacT RHUs is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. It can activate an alarm and a pre-alarm. The operational supply voltage is 110/130VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity is from 30mA to 30A. The time delay is adjustable from 0 to 4.5s. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor. It complies with IEC 60755, IEC 60947-2 annex M and IEC 60947-5-1 standards.

Technical Specifications

Range

VigiPacT

Device short name

RHUs

Product or component type

Residual current protection relay

Relay application

Monitoring relay Protection relay

mounting support

Front panel

Earth-leakage protection class

Type A

Type of setting

Keypad

Residual earth-leakage sensitity adjustment type

Adjustable

Earth-leakage sensitivity

0.03…1 A, adjustable in step of 0.001 A 1…30 A, adjustable in step of 0.1 A

Earth-leakage time delay

Instantaneous for 0.03 A Adjustable 0…4.5 s for 0.03…30 A adjustable in step of 10 ms

Threshold setting

0.015...1 A adjustable in step of 0.001 A pre-alarm 1...30 A adjustable in step of 0.1 A pre-alarm 0.03...1 A adjustable in step of 0.001 A alarm 1...30 A adjustable in step of 0.1 A alarm

Current sensors compatibility

VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor

[Ithe] conventional enclosed thermal current

8 A

Minimum load

10 mA at 12 V

[Us] rated supply voltage

110...130 V AC 50/60 Hz 70...110 %

Power consumption in VA

8 VA

Monitored distribution system

1000 V - AC at 50/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum)

Earthing system

TT TN-S IT

[Uimp] rated impulse withstand voltage

8 kV

Reset

Manual reset

Test function

Local Remote test

Signal contacts composition

1 C/O alarm fail-safe 1 NO pre-alarm fail-safe

Type of measurement

Earth fault current internal measurement, range: 20...200 %, accuracy: +/- 20 %

Refresh time

0.5 s

Tamperproof of settings

Protected by access code

Connections - terminals

Alarm circuit: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Alarm circuit: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12 Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12 Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12 Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12 Power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12 Pre alarm: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12 Pre alarm: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12

Wire stripping length

Alarm circuit: 6 mm Relay test and fault reset: 6 mm Sensor: 6 mm Voltage presence: 6 mm Power supply: 6 mm Pre alarm: 6 mm

Tightening torque

Alarm circuit: 0.5 N.m Relay test and fault reset: 0.5 N.m Sensor: 0.5 N.m Voltage presence: 0.5 N.m Power supply: 0.5 N.m Pre alarm: 0.5 N.m

Standards

EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144

Width

72 mm

height

72 mm

Depth

117 mm

Cut-out dimensions

68 x 68 mm

Net weight

0.3 kg

IP degree of protection

IP40 front face: conforming to IEC 60529 IP30 other parts: conforming to IEC 60529 IP20 connection: conforming to IEC 60529

IK degree of protection

IK07 conforming to EN 50102

Mechanical robustness

Vibrations 13.2...100 Hz: 0.7 g Vibrations 2...13.2 Hz: +/- 1 mm

Environmental characteristic

Exposure to damp heat not in service conforming to IEC 60068-2-30 Exposure to damp heat in service conforming to IEC 60068-2-56 Salt mist conforming to IEC 60068-2-52

Overvoltage category

IV

Electrical shock protection class

Class II

Electromagnetic compatibility

Conducted and radiated emissions: , B, conforming to CISPR 11 Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 Radiated susceptibility: , 3, conforming to IEC 61000-4-3

Relative humidity

95 % at 55 °C

Pollution degree

3 conforming to IEC 60664-1

ambient air temperature for operation

-25…55 °C

Ambient air temperature for storage

-40…85 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

8.0 cm

Package 1 Width

11.0 cm

Package 1 Length

16.0 cm

Package 1 Weight

546.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

8

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

4.487 kg

Warranty

18 months

Document Links

Catalogue page

Datasheet