1SBL297201R1300

AF38-40-00-13 100-250V50/60HZ-DC

Trade Price

£156.20

Per

1

Unit

EA

Pack Quantity

1

1SBL297201R1300

Information

AF09...AF38 4 Pole contactor - 25 to 55A AC-1 AC/DC operated, 4 N.O main poles * Part number: AF38-40-00-13 * AF09 ... AF38 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These contactors are of the block type design with 4 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening. * Built-in surge suppression * Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

45 mm

Product Net Depth / Length

101 mm

Product Net Height

86 mm

Product Net Weight

0.36 kg

Number of Main Contacts NO

4

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

0

Number of Auxiliary Contacts NC

0

Standards

IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1

Rated Operational Voltage

Main Circuit 690 V

Rated Frequency (f)

Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A

Rated Operational Current AC-1 (Ie)

(690 V) 40 °C 55 A(690 V) 60 °C 45 A(690 V) 70 °C 37 A

Rated Operational Current AC-3 (Ie)

(415 V) 60 °C 21.2 A(440 V) 60 °C 20 A(500 V) 60 °C 17.6 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 22 A(220 / 230 / 240 V) 60 °C 23.2 A

Rated Operational Power AC-3 (Pe)

(400 V) 11 kW(415 V) 11 kW(440 V) 11 kW(500 V) 11 kW(690 V) 9 kW(220 / 230 / 240 V) 5.5 kW

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A

Maximum Electrical Switching Frequency

(AC-1) 600 cycles per hour

Rated Operational Current DC-1 (Ie)

(110 V) 2 Poles in Series, 40 °C 55 A(110 V) 2 Poles in Series, 60 °C 45 A(110 V) 2 Poles in Series, 70 °C 37 A(110 V) 3 Poles in Series, 40 °C 55 A(110 V) 3 Poles in Series, 60 °C 45 A(110 V) 3 Poles in Series, 70 °C 37 A(110 V) 4 Poles in Series, 40 °C 55 A(110 V) 4 Poles in Series, 60 °C 45 A(110 V) 4 Poles in Series, 70 °C 37 A(220 V) 3 Poles in Series, 40 °C 55 A(220 V) 3 Poles in Series, 60 °C 45 A(220 V) 3 Poles in Series, 70 °C 37 A(220 V) 4 Poles in Series, 40 °C 55 A(220 V) 4 Poles in Series, 60 °C 45 A(220 V) 4 Poles in Series, 70 °C 37 A(72 V) 1-Pole, 40 °C 55 A(72 V) 1-Pole, 60 °C 45 A(72 V) 1-Pole, 70 °C 37 A(72 V) 2 Poles in Series, 40 °C 55 A(72 V) 2 Poles in Series, 60 °C 45 A(72 V) 2 Poles in Series, 70 °C 37 A(72 V) 3 Poles in Series, 40 °C 55 A(72 V) 3 Poles in Series, 60 °C 45 A(72 V) 3 Poles in Series, 70 °C 37 A(72 V) 4 Poles in Series, 40 °C 55 A(72 V) 4 Poles in Series, 60 °C 45 A(72 V) 4 Poles in Series, 70 °C 37 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

6 kV

Maximum Mechanical Switching Frequency

3600 cycles per hour

Rated Control Circuit Voltage (Uc)

50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V

Operate Time

Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms

Mounting on DIN Rail

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied)

2 x M4 screws placed diagonally

Connecting Capacity Main Circuit

Flexible with Ferrule 1/2x 1.5 ... 16 mm²Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm²Rigid Solid 1/2x 1.5 ... 4 mm²Rigid Stranded 1/2x 1.5 ... 16 mm²

Connecting Capacity Control Circuit

Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²

Wire Stripping Length

Control Circuit 10 mmMain Circuit 12 mm

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20

Terminal Type

Screw Terminals

Maximum Operating Voltage UL/CSA

Main Circuit 600 V

General Use Rating UL/CSA

(600 V AC) 55 A

Connecting Capacity Main Circuit UL/CSA

Rigid Solid 1/2x 16-10 AWGRigid Stranded 1/2x 16-6 AWG

Connecting Capacity Control Circuit UL/CSA

Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG

Tightening Torque UL/CSA

Control Circuit 11 in·lbMain Circuit 22 in·lb

Ambient Air Temperature

Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C

Climatic Withstand

Category B according to IEC 60947-1 Annex Q

Maximum Operating Altitude Permissible

Without Derating 3000 m

Resistance to Shock acc. to IEC 60068-2-27

Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g

Resistance to Vibrations acc. to IEC 60068-2-6

5 ... 300 Hz 4 g closed position / 2 g open position

RoHS Status

Following EU Directive 2011/65/EU

Package Level 1 Units

box 1 piece

Package Level 1 Width

87 mm

Package Level 1 Depth / Length

103 mm

Package Level 1 Height

47 mm

Package Level 1 Gross Weight

0.36 kg

Package Level 1 EAN

3471523115330

Package Level 2 Units

box 18 piece

Package Level 2 Width

250 mm

Package Level 2 Depth / Length

300 mm

Package Level 2 Height

315 mm

Package Level 2 Gross Weight

12.96 kg

Package Level 3 Units

864 piece

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3705838

E-Number (Sweden)

3211520

Document Links