1SFL607002R1111

AF370-30-11-11 24-60V50/60HZ-DC

Trade Price

£1,742.04

Per

1

Unit

EA

Pack Quantity

1

1SFL607002R1111

Information

AF190...AF370 3 Pole contactors - 55 to 200kW AC/DC operated 1NO+1NC aux * Part number: AF370-30-11-11 * AF146.AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000V AC. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

140 mm

Product Net Depth / Length

180 mm

Product Net Height

225 mm

Product Net Weight

3.9 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Main Circuit 1000 V

Rated Frequency (f)

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A

Rated Operational Current AC-1 (Ie)

(1000 V) 40 °C 400 A(1000 V) 55 °C 350 A(1000 V) 60 °C 350 A(1000 V) 70 °C 290 A(690 V) 40 °C 600 A(690 V) 55 °C 500 A(690 V) 70 °C 400 A

Rated Operational Current AC-3 (Ie)

(415 V) 55 °C 370 A(440 V) 55 °C 370 A(500 V) 55 °C 350 A(690 V) 55 °C 315 A(1000 V) 55 °C 141 A(380 / 400 V) 55 °C 370 A(220 / 230 / 240 V) 55 °C 370

Rated Operational Power AC-3 (Pe)

(415 V) 200 kW(440 V) 200 kW(500 V) 250 kW(690 V) 315 kW(1000 V) 200 kW(380 / 400 V) 200 kW(220 / 230 / 240 V) 110 kW

Rated Breaking Capacity AC-3

8 x Ie AC-3

Rated Making Capacity AC-3

10 x Ie AC-3

Short-Circuit Protective Devices

gG Type Fuses 630 A

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A

Maximum Electrical Switching Frequency

(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour

Rated Operational Current DC-1 (Ie)

(110 V) 2 Poles in Series, 40 °C 450 A(220 V) 3 Poles in Series, 40 °C 450 A

Rated Operational Current DC-3 (Ie)

(110 V) 2 Poles in Series, 40 °C 450 A(220 V) 3 Poles in Series, 40 °C 450 A

Rated Operational Current DC-5 (Ie)

(110 V) 2 Poles in Series, 40 °C 450 A(220 V) 3 Poles in Series, 40 °C 450 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Mechanical Durability

5 million

Maximum Mechanical Switching Frequency

300 cycles per hour

Coil Operating Limits

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc)

50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation 20 ... 60 V

Coil Consumption

Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·AHolding at Max. Rated Control Circuit Voltage DC 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·APull-in at Max. Rated Control Circuit Voltage DC 400 W

Operate Time

Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms

Connecting Capacity Main Circuit

Flexible 1 x 16 ... 240 mm²Rigid Al-Cable 1 x 185 ... 240 mm²Rigid Cu-Cable 2 x 70 ... 185 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type

Main Circuit: Bars

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V

General Use Rating UL/CSA

(600 V AC) 520 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 125 hp(208 V AC) Three Phase 125 hp(220 ... 240 V AC) Three Phase 150 hp(440 ... 480 V AC) Three Phase 300 hp(550 ... 600 V AC) Three Phase 350 hp

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible

Without Derating 3000 m

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

ABB EcoSolutions

Yes

Circular Design Principles Recyclability Rate

Design for Closing Resource Loops - Standard EN45555 - 76.3 %

Group Waste to Landfill Target

Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility

Improved Resource Efficiency for Customers

Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line

Sustainable Material Content

Recycled Metal - 33 %

Package Level 1 Units

box 1 piece

Package Level 1 Width

263 mm

Package Level 1 Depth / Length

203 mm

Package Level 1 Height

289 mm

Package Level 1 Gross Weight

4.6 kg

Package Level 1 EAN

7320500481837

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3706492

E-Number (Norway)

4117656

E-Number (Sweden)

3210169

Document Links