1SFL617001R7111

AF580-30-11 250-500V AC/DC Contactor

Trade Price

£3,107.91

Per

1

Unit

EA

Pack Quantity

1

1SFL617001R7111

Information

AF400...AF750 3 Pole contactor * Part number: AF580-30-11 * AF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC or 600 V DC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories * AF400 ... AF750 are equipped with low voltage inputs for control, for example by a PLC.

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

210 mm

Product Net Depth / Length

242 mm

Product Net Height

283 mm

Product Net Weight

13.6 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Main Circuit 1000 V

Rated Frequency (f)

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A

Rated Operational Current AC-1 (Ie)

(1000 V) 40 °C 800 A(1000 V) 55 °C 700 A(1000 V) 70 °C 580 A(690 V) 40 °C 800 A(690 V) 55 °C 700 A(690 V) 70 °C 580 A

Rated Operational Current AC-3 (Ie)

(415 V) 55 °C 580 A(440 V) 55 °C 580 A(500 V) 55 °C 580 A(690 V) 55 °C 500 A(1000 V) 55 °C 250 A(380 / 400 V) 55 °C 580 A(220 / 230 / 240 V) 55 °C 580

Rated Operational Power AC-3 (Pe)

(415 V) 355 kW(440 V) 355 kW(500 V) 400 kW(690 V) 500 kW(1000 V) 355 kW(380 / 400 V) 315 kW(220 / 230 / 240 V) 160 kW

Rated Breaking Capacity AC-3

8 x Ie AC-3

Rated Making Capacity AC-3

10 x Ie AC-3

Short-Circuit Protective Devices

gG Type Fuses 1000 A

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A

Maximum Electrical Switching Frequency

(AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour

Rated Operational Current DC-1 (Ie)

(110 V) 1-Pole, 40 °C 800 A(110 V) 2 Poles in Series, 40 °C 800 A(220 V) 3 Poles in Series, 40 °C 800 A(600 V) 3 Poles in Series, 40 °C 800 A(850 V) 3 Poles in Series, 40 °C 800 A

Rated Operational Current DC-3 (Ie)

(110 V) 1-Pole, 40 °C 800 A(110 V) 2 Poles in Series, 40 °C 800 A(220 V) 3 Poles in Series, 40 °C 800 A(600 V) 3 Poles in Series, 40 °C 800 A

Rated Operational Current DC-5 (Ie)

(110 V) 1-Pole, 40 °C 800 A(110 V) 2 Poles in Series, 40 °C 800 A(220 V) 3 Poles in Series, 40 °C 800 A(600 V) 3 Poles in Series, 40 °C 800 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Mechanical Durability

3 million

Maximum Mechanical Switching Frequency

300 cycles per hour

Coil Operating Limits

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc)

50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V

Coil Consumption

Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 7.5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·APull-in at Max. Rated Control Circuit Voltage DC 910 V·A

Operate Time

Between Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms

Connecting Capacity Main Circuit

Bar 52 mm²Rigid Al-Cable 3x185 mm²Rigid Cu-Cable 300 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type

Main Circuit: Bars

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V

General Use Rating UL/CSA

(600 V AC) 750 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 200 hp(208 V AC) Three Phase 200 hp(220 ... 240 V AC) Three Phase 250 hp(440 ... 480 V AC) Three Phase 500 hp(550 ... 600 V AC) Three Phase 600 hp

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible

Without Derating 3000 m

Resistance to Shock acc. to IEC 60068-2-27

Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Package Level 1 Units

box 1 piece

Package Level 1 Width

280 mm

Package Level 1 Depth / Length

375 mm

Package Level 1 Height

310 mm

Package Level 1 Gross Weight

15 kg

Package Level 1 EAN

7320500250228

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3709252

E-Number (Norway)

4115297

E-Number (Sweden)

3228355

Document Links