1SBL411025R8011

GA75-10-11 220-230V 50Hz Contactor

Trade Price

£652.93

Per

1

Unit

EA

Pack Quantity

1

1SBL411025R8011

Information

GA75 1 pole contactors - 100A DC-1 AC operated * Part number: GA75-10-11 * GA75 contactors are designed for controlling shunt or series motors and resistive or slightly inductive loads up to 1000 V DC. * These contactors are of the block type design with 3 main poles connected in series. - main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection polarities must be respected. - control circuit: AC operated - add-on auxiliary contact blocks for side mounting and a wide range of accessories.

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

82 mm

Product Net Depth / Length

108 mm

Product Net Height

132 mm

Product Net Weight

1.26 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Auxiliary Circuit 690 VMain Circuit 1000 V DC

Rated Frequency (f)

Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A

Rated Operational Current AC-15 (Ie)

(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A

Short-Circuit Protective Devices

Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 160 A

Rated Short-time Withstand Current Low Voltage (Icw)

for 0.1 s 140 Afor 1 s 100 A

Maximum Electrical Switching Frequency

300 cycles per hour

Rated Operational Current DC-1 (Ie)

(1000 V) 1-Pole, 40 °C 35 A(1000 V) 1-Pole, 55 °C 35 A(1000 V) 1 Pole, 70 °C 35 A(110 V) 1-Pole, 40 °C 120 A(110 V) 1-Pole, 55 °C 100 A(110 V) 1-Pole, 70 °C 85 A(220 V) 1-Pole, 40 °C 120 A(220 V) 1-Pole, 55 °C 100 A(220 V) 1-Pole, 70 °C 85 A(440 V) 1-Pole, 40 °C 100 A(440 V) 1-Pole, 55 °C 100 A(440 V) 1-Pole, 70 °C 85 A(600 V) 1-Pole, 40 °C 75 A(600 V) 1-Pole, 55 °C 75 A(600 V) 1-Pole, 70 °C 75 A(72 V) 1-Pole, 40 °C 120 A(72 V) 1-Pole, 55 °C 100 A(72 V) 1-Pole, 70 °C 85 A

Rated Operational Current DC-3 (Ie)

(110 V) 1-Pole, 40 °C 120 A(110 V) 1-Pole, 55 °C 100 A(220 V) 1-Pole, 40 °C 100 A(220 V) 1-Pole, 55 °C 100 A(440 V) 1-Pole, 40 °C 85 A(440 V) 1-Pole, 55 °C 85 A(72 V) 1-Pole, 40 °C 120 A(72 V) 1-Pole, 55 °C 100 A

Rated Operational Current DC-5 (Ie)

(110 V) 1-Pole, 40 °C 85 A(110 V) 1-Pole, 55 °C 85 A(220 V) 1-Pole, 40 °C 85 A(220 V) 1-Pole, 55 °C 85 A(440 V) 1-Pole, 40 °C 35 A(440 V) 1-Pole, 55 °C 35 A(72 V) 1-Pole, 40 °C 85 A(72 V) 1-Pole, 55 °C 85 A

Rated Operational Current DC-13 (Ie)

(24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.30 A / 66 W(250 V) 0.3 / 75 W

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 1000 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

8 kV

Mechanical Durability

10 million

Maximum Mechanical Switching Frequency

3600 cycles per hour

Rated Control Circuit Voltage (Uc)

50 Hz 220 ... 230 V60 Hz 230 ... 240 V

Coil Consumption

Average Holding Value 50 / 60 Hz 18 V·AAverage Pull-in Value 50 Hz 190 V·AAverage Pull-in Value 60 Hz 180 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 18 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 5.5 WHolding at Max. Rated Control Circuit Voltage 60 Hz 18 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 5.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A

Operate Time

Between Coil De-energization and NC Contact Closing 7 ... 14 msBetween Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NC Contact Opening 7 ... 22 msBetween Coil Energization and NO Contact Closing 8 ... 27 ms

Mounting on DIN Rail

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied)

2 x M6 screws placed diagonally

Connecting Capacity Main Circuit

Flexible with Cable End 6 ... 16 mm²Rigid Cable 6 ... 25 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Cable End 0.75 ... 2.5 mm²Rigid Cable 1 ... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

Connecting Terminals (delivered in open position) Main Poles

M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector

Terminal Type

Screw Terminals

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V DC

General Use Rating UL/CSA

(1000 V DC) 35 A(440 V DC) 100 A(600 V DC) 75 A

Ambient Air Temperature

Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °CNear Contactor for Operation in Free Air (Uc) -40 ... 70 °C

Climatic Withstand

acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Maximum Operating Altitude Permissible

Without Derating 3000 m

RoHS Status

Following EU Directive 2011/65/EU

Package Level 1 Units

box 1 piece

Package Level 1 Width

140 mm

Package Level 1 Depth / Length

146 mm

Package Level 1 Height

96 mm

Package Level 1 Gross Weight

1.26 kg

Package Level 1 EAN

3471522100801

Package Level 2 Units

box 63 piece

Package Level 2 Gross Weight

79.38 kg

Object Classification Code

Q

ETIM 4

EC002552 - Power contactor, DC switching

ETIM 5

EC002552 - Power contactor, DC switching

ETIM 6

EC002552 - Power contactor, DC switching

ETIM 7

EC002552 - Power contactor, DC switching

ETIM 8

EC002552 - Power contactor, DC switching

eClass

V11.0 : 27371018

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4763 >> Power contactor, DC switching

Document Links

Catalogue page

Datasheet