1SAM451000R1015

Manual motor starter 30-42A, MS165-42

Trade Price

£202.76

Per

1

Unit

EA

Pack Quantity

1

1SAM451000R1015

Information

MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS116/MS132/MS165 range.

Technical Specifications

Minimum Order Quantity:

1 piece

Customs Tariff Number:

85362010

Product Net Width:

55 mm

Product Net Height:

142.65 mm

Product Net Depth / Length:

122.1 mm

Product Net Weight:

0.97 kg

Rated Service Short-Circuit Breaking Capacity (Ics):

(230 V AC) 50 kA(250 V DC) 3 Poles in Series 100 kA(400 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(690 V AC) 10 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu):

(230 V AC) 50 kA(250 V DC) 100 kA(400 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(690 V AC) 10 kA

Rated Instantaneous Short-Circuit Current Setting (Ii):

630 A

Setting Range:

30 ... 42 A

Rated Operational Power AC-3 (Pe):

(400 V) Three Phase 22 kW

Rated Operational Power AC-3e (Pe):

(400 V) Three Phase 22 kW

Rated Operational Voltage:

Main Circuit 690 V ACMain Circuit 250 V DC

Rated Operational Current (Ie):

42 A

Rated Operational Current AC-3 (Ie):

42 A

Rated Operational Current AC-3e (Ie):

42 A

Rated Operational Current DC-5 (Ie):

42 A

Rated Frequency (f):

Main Circuit 50 HzMain Circuit 60 Hz

Operating Frequency (fsw):

0 ... 415 Hz

Rated Impulse Withstand Voltage (Uimp):

Main Circuit 8 kV

Rated Insulation Voltage (Ui):

1000 V

Power Loss:

at Rated Operating Conditions per Pole 2.79 ... 5.47 W

Number of Poles:

3

Conventional Free-air Thermal Current (Ith):

Main Circuit 42 A

Degree of Protection:

Housing IP20Main Circuit Terminals IP10

Pollution Degree:

3

Electrical Durability:

25000 cycle

Mechanical Durability:

50000 cycle

Terminal Type:

Screw Terminals

Connecting Capacity Main Circuit:

Flexible with Ferrule 1/2x 1 ... 35 mm²Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²Flexible 1/2x 1 ... 35 mm²Rigid 1/2x 1 ... 4 mm²Solid 1/2x 1 ... 4 mm²Stranded 1/2x 1 ... 50 mm²

Tightening Torque:

Main Circuit 4 N·m

Wire Stripping Length:

Main Circuit 16 mm

Recommended Screw Driver:

Pozidriv 2

Mounting Position:

1 ... 6

Mounting on DIN Rail:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Minimum Mounting Distance:

Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mmElectrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm

Actuator Type:

Rotary Handle

Contact Position Indication:

ON / OFF / TRIP

Standards:

CSA 22.2 No. 14IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-4-1

Short-Circuit Current Rating (SCCR):

Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kAManual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA

Maximum Operating Voltage UL/CSA:

Main Circuit 600 V AC

Horsepower Rating UL/CSA:

(200 V AC) Three Phase 10 Hp(208 V AC) Three Phase 10 Hp(220 ... 240 V AC) Three Phase 15 Hp(440 ... 480 V AC) Three Phase 30 Hp(550 ... 600 V AC) Three Phase 40 Hp

Full Load Amps Motor Use:

(200 V AC) Three Phase 32.2 A(208 V AC) Three Phase 30.8 A(220 ... 240 V AC) Three Phase 42 A(440 ... 480 V AC) Three Phase 40 A(550 ... 600 V AC) Three Phase 41 A

Locked Rotor Amps:

(200 V AC) Three Phase 186.3 A(208 V AC) Three Phase 179 A(220 ... 240 V AC) Three Phase 232 A(440 ... 480 V AC) Three Phase 218 A(550 ... 600 V AC) Three Phase 232 A

General Use Rating UL/CSA:

(600 V AC) 42 A

Connecting Capacity Main Circuit UL/CSA:

Flexible 1/2x 16-0 AWGStranded 1/2x 16-0 AWG

Tightening Torque UL/CSA:

Main Circuit 35 in·lb

Ambient Air Temperature:

Operation -25 ... +60 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C

Ambient Air Temperature Compensation:

Yes

Maximum Operating Altitude Permissible:

2000 m

Resistance to Shock acc. to IEC 60068-2-27:

11 ms Pulse 25g

Resistance to Vibrations:

Mounted on DIN-Rail: 4g 3 … 160 Hz

RoHS Status:

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Package Level 1 Units:

box 1 piece

Package Level 1 Width:

64 mm

Package Level 1 Depth / Length:

177 mm

Package Level 1 Height:

140 mm

Package Level 1 Gross Weight:

1.1 kg

Package Level 1 EAN:

4013614486098

Package Level 2 Units:

carton 12 piece

Package Level 2 Width:

330 mm

Package Level 2 Depth / Length:

400 mm

Package Level 2 Height:

320 mm

Package Level 2 Gross Weight:

13 kg

Package Level 2 EAN:

4013614503955

Object Classification Code:

F

ETIM 5:

EC000074 - Motor protective circuit-breaker

ETIM 6:

EC000074 - Motor protection circuit-breaker

ETIM 7:

EC000074 - Motor protection circuit-breaker

ETIM 8:

EC000074 - Motor protection circuit-breaker

eClass:

V11.0 : 27370401

UNSPSC:

39121521

IDEA Granular Category Code (IGCC):

4731 >> Manual Starters

E-Number (Finland):

3707288

E-Number (Sweden):

3110055

Document Links