1SFA898109R7000

PSTX105-600-70 Softstarter

Trade Price

£2,812.38

Per

1

Unit

EA

Pack Quantity

1

1SFA898109R7000
1SFA898109R7000
1SFA898109R7000
1SFA898109R7000

Information

PSTX30...PSTX370 Softstarters * Part number: PSTX105-600-70 * The PSTX combines many years of research and product development with extensive knowledge of application specific requirements and needs. It is our latest advancement in motor control and protection and adds new functionality and increased reliability. * Complete motor protection * Three types of current limit * Built-in bypass for time and energy saving * Easy-to-use and detachable keyboard * Complete control of pumps * Jog with slow speed

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85371091

Product Net Width

150 mm

Product Net Height

314 mm

Product Net Depth / Length

198 mm

Product Net Weight

4.7 kg

Rated Operational Voltage

208 ... 600 V AC

Rated Control Supply Voltage (Us)

100 ... 250 V AC

Rated Control Circuit Voltage (Uc)

24 V DC

Rated Frequency (f)

50/60 HzMain Circuit 50 / 60 Hz

Rated Operational Power - In-Line Connection (Pe)

(230 V) 30 kW(400 V) 55 kW(500 V) 75 kW

Rated Operational Current - In-Line Connection (Ie)

105 A

Rated Operational Power - Inside Delta Connection

at 230 V 55 kWat 400 V 90 kWat 500 V 110 kW

Rated Operational Current - Inside Delta Connection

181 A

Service Factor Percentage

100 %

Overload Protection

Built-in electronic overload protection

Integrated Electronic Overload

Yes

Adjustable Rated Motor Current Ie

30 ... 100 %

Starting Capacity at Maximum Rated Current Ie

4xIe for 10s

Ramp Time

1 ... 120 second [unit of time]

Initial Voltage During Start

10 ... 99 %

Step Down Voltage Special Ramp

100 ... 10 %

Current Limit Function

1.5 ... 7.5 xle

Switch for Inside Delta Connection

Yes

Run Signal Relay

Yes

By-pass Signal Relay

Yes

Fault Signal Relay

Yes

Overload Signal Relay

Yes

Analog Outputs

0…10 V, 0…20 mA, 4…20 mA

Signal Indication Ready to Start/Standby ON (LED)

Green

Signal Indication Running R (LED)

Green

Signal Indication Protection (LED)

Yellow

Signal Indication Fault (LED)

Red

Communication

Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP

Degree of Protection

IP00

Terminal Type

Cable Clamp

Connecting Capacity Main Circuit

Hole Diameter 8.5 mm

Connecting Capacity Control Circuit

Rigid 1 x 2.5 mm²

Connecting Capacity Supply Circuit

Rigid 1 x 2.5 mm²

Tightening Torque

Main Circuit 8 N·m

Product Main Type

PSTX105

Function

Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logFull voltage startJog with slow speed, forward and reverseKeypad passwordKick startLimp mode with two-phase motor control if one set of thyristors is shortedMotor heatingPre-start functionPump cleaningReal time clockSequence startSoft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampStand still brakeStart reverse (external contactors)Thyristor runtime measurementTorque limitVoltage sags detection

Protection Function

Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection

Warning Details

Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Maximum Operating Voltage UL/CSA

Main Circuit 600 V

Tightening Torque UL/CSA

Main Circuit 70.8

Ambient Air Temperature

Operation -25 ... +60 °CStorage -40 ... +70 °C

RoHS Status

Following EU Directive 2002/95/EC August 18, 2005 and amendment

Package Level 1 Width

200 mm

Package Level 1 Depth / Length

282 mm

Package Level 1 Height

388 mm

Package Level 1 Gross Weight

5.7 kg

Package Level 1 EAN

7320500501313

Package Level 1 Units

box 1 piece

Object Classification Code

Q

ETIM 7

EC000640 - Soft starter

ETIM 8

EC000640 - Soft starter

ETIM 9

EC000640 - Soft starter

eClass

V11.0 : 27370907

UNSPSC

39121521

IDEA Granular Category Code (IGCC)

4740 >> Soft starter

Document Links