NZM-XBZ600

Bowden cable 225-600mm

Trade Price

£62.38

Per

1

Unit

EACH

Pack Quantity

NZM-XBZ600

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Bowden cables, L=600mm

Technical Specifications

Product Length/Depth

200 mm

Product Height

50 mm

Product Width

200 mm

Product Weight

0.115 kg

Compliances

IEC

UL/CSA

RoHS conform

Certifications

CE marking

IEC60947

CSA certified

UL (File No. E140305)

UL listed

CSA (Class No. 1437-01)

UL489

CSA-C22.2 No. 5-09

CSA (File No. 22086)

UL (Category Control Number DIHS)

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM1/2/3/4

Accessory/spare part type

Other

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Special features

For mechanical interlocking of (door coupling) rotary handles

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Type

Accessory. Mechanical interlock

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

N3-4

PN2-4

NS2

NZM1(-4), PN1(-4), N(S)1(-4)

NZM2

N1-4

PN1-4

N3

N4-4

NS4

NZM3

NZM3-4

NZM4-4

NS1

NS3

NZM1

NZM4

NZM4(-4), N(S)4(-4)

PN3

N1

N2

NZM2-4

NZM1-4

NZM2(-4), PN2(-4), N(S)2(-4)

PN1

N2-4

N4

NZM3(-4), PN3(-4), N(S)3(-4)

PN2

PN3-4

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Document Links

Datasheet