NZM1-XUHIV20KL110-130AC

UV release+2N/O(EM) screw terminals N(ZM)1 110-130AC

Trade Price

£151.83

Per

1

Unit

EACH

Pack Quantity

NZM1-XUHIV20KL110-130AC
NZM1-XUHIV20KL110-130AC
NZM1-XUHIV20KL110-130AC

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Undervoltage release, 110-130VAC +2early N/O, HIV20KL

Technical Specifications

Product Length/Depth

37 mm

Product Height

66 mm

Product Width

32 mm

Product Weight

0.056 kg

Warranty

Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.

Compliances

UL/CSA

IEC

RoHS conform

Certifications

CSA certified

CSA (File No. 22086)

IEC60947

UL listed

UL (File No. E140305)

UL489

CE marking

CSA-C22.2 No. 5-09

UL (Category Control Number DIHS)

CSA (Class No. 1437-01)

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Rated control supply voltage (Us) at AC, 50 Hz - min

110 V

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Minimum command time - min

10 ms

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Pick-up power consumption at AC (undervoltage release)

1.5 VA

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Rated control supply voltage (Us) at DC - min

0 V

Fitted with:

Two separate early-make auxiliary contacts

Pick-up power consumption at DC (undervoltage release)

0.8 W

Rated control supply voltage (Us) at AC, 50 Hz - max

130 V

10.8 Connections for external conductors

Is the panel builder's responsibility.

Minimum command time - max

15 ms

Special features

Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.

For use with emergency-stop devices in connection with an emergency-stop button.

When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.

Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms

Cannot be used in conjunction with NZM...-XR... remote operator.

Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.

Rated control supply voltage (Us) at DC - max

0 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Rated control supply voltage

110 - 130 V 50/60 Hz

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

NZM1(-4), N(S)1(-4)

Electric connection type

Screw connection

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Voltage type

AC

Drop-out voltage of undervoltage release AC/DC - min

0.35 x Us

Frame

NZM1

Reaction time

19 ms

Suitable for

Off-load switch

Voltage tolerance - min

.85

Rated control voltage (relay contacts)

130 V AC

110 V AC

Power consumption

1.5 VA (sealing AC)

0.8 W (sealing DC)

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

Drop-out voltage of undervoltage release AC/DC - max

0.7 x Us

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

Connection type

Coil terminals wired to terminal block

Auxiliary contact terminals with 3 m of loose connection cables

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Voltage tolerance - max

1.1

Undelayed short-circuit release - min

0 A

Rated control supply voltage (Us) at AC, 60 Hz - min

110 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Terminal capacity (solid/flexible conductor)

18 - 14 AWG (2x) for undervoltage releases, off-delayed

18 - 14 AWG (1x) for undervoltage releases, off-delayed

0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule

18 - 14 AWG (1x) at shunt release

0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule

0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule

18 - 14 AWG (2x) at shunt release

0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule

Connection

Screw

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Type

Accessory

Undervoltage release with early-make auxiliary contact

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

Rated control supply voltage (Us) at AC, 60 Hz - max

130 V

Number of contacts (normally open contacts)

2

Undelayed short-circuit release - max

0 A

Number of contacts (change-over contacts)

0