Eaton Moeller series NZM - Molded Case Circuit Breaker. Relay module for NZM2/3, configurable, 2NO, 24DC, 24-230AC, PI
Product Length/Depth
115 mm
Product Height
65 mm
Product Width
75 mm
Product Weight
0.06 kg
Compliances
UL/CSA
IEC
RoHS conform
Certifications
UL listed
CSA (Class No. 1437-01)
CSA certified
UL (Category Control Number DIHS)
CE marking
UL (File No. E140305)
IEC60947
UL489
CSA-C22.2 No. 5-09
CSA (File No. 22086)
Terminal capacity (stranded cable)
0.25 mm² - 0.75 mm² (1x) at supply connection (uninsulated ferrule according to DIN46224 / 1)
0.25 mm² - 1.5 mm² (1x) at supply connection (insulated ferrule according to DIN46224 / 4)
0.25 mm² - 1.5 mm² (1x) at supply connection
24 - 16 AWG (1x) at relay contacts
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Frame
NZM2/3
Accessory/spare part type
Relay module
Other
Accessory
Terminal capacity (solid cable)
0.2 mm² - 1.5 mm² (1x) at supply connection
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Strip length
8 mm (supply connection)
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Rated control voltage (relay contacts)
24 V AC
24 V DC
240 V AC
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.8 Connections for external conductors
Is the panel builder's responsibility.
Connection type
With push in terminal
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Number of relays
2
Special features
For signalizing commands or different states of the circuit-breaker.
Two relays per unit.
The activation criteria can be configured in the trip unit.
Configuration via communication or circuit breaker display or front USB port and Eaton Power Xpert Protection Manager.
Only for use in combination with circuit-breakers with electronic trips.
Relay components cannot be installed simultaneously with make-before-break auxiliary breaker NZM...-XHIV, the under-voltage trip NZM...-XU.... or the shunt trip NZM...-XA....
Relay contacts for control wiring.
Relays can be used for controlling remote operator with Us=208-204 V AC.
Control wiring on push-in clamps.
Cannot be used with the PXR10 NZM-AX electronic trip.
Pollution degree
2
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Rated impulse withstand voltage (Uimp)
4 kV AC
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (reference value) - min
0.1 mA / 0.1 VDC
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Type
Accessory
Relay module
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Used with
PXR20(25) NZM2(-4)-..X…
PXR20(25) NZM3(-4)-..X…
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Rated operational current
1 A (230 V AC-1, relay contacts)
1 A (24 V DC-1, relay outputs)
1 A (24 V AC-1, relay contacts)
1 A (110 V AC-1, relay contacts)
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Rated insulation voltage (Ui)
250 V