NZM2/3-X2A

Relay module,2NO,24DC,24-230AC,PI

Trade Price

£62.49

Per

1

Unit

EACH

Pack Quantity

NZM2/3-X2A
NZM2/3-X2A
NZM2/3-X2A
NZM2/3-X2A

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Relay module for NZM2/3, configurable, 2NO, 24DC, 24-230AC, PI

Technical Specifications

Product Length/Depth

115 mm

Product Height

65 mm

Product Width

75 mm

Product Weight

0.06 kg

Compliances

UL/CSA

IEC

RoHS conform

Certifications

UL listed

CSA (Class No. 1437-01)

CSA certified

UL (Category Control Number DIHS)

CE marking

UL (File No. E140305)

IEC60947

UL489

CSA-C22.2 No. 5-09

CSA (File No. 22086)

Terminal capacity (stranded cable)

0.25 mm² - 0.75 mm² (1x) at supply connection (uninsulated ferrule according to DIN46224 / 1)

0.25 mm² - 1.5 mm² (1x) at supply connection (insulated ferrule according to DIN46224 / 4)

0.25 mm² - 1.5 mm² (1x) at supply connection

24 - 16 AWG (1x) at relay contacts

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM2/3

Accessory/spare part type

Relay module

Other

Accessory

Terminal capacity (solid cable)

0.2 mm² - 1.5 mm² (1x) at supply connection

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Strip length

8 mm (supply connection)

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Rated control voltage (relay contacts)

24 V AC

24 V DC

240 V AC

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

Connection type

With push in terminal

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Overvoltage category

III

Number of relays

2

Special features

For signalizing commands or different states of the circuit-breaker.

Two relays per unit.

The activation criteria can be configured in the trip unit.

Configuration via communication or circuit breaker display or front USB port and Eaton Power Xpert Protection Manager.

Only for use in combination with circuit-breakers with electronic trips.

Relay components cannot be installed simultaneously with make-before-break auxiliary breaker NZM...-XHIV, the under-voltage trip NZM...-XU.... or the shunt trip NZM...-XA....

Relay contacts for control wiring.

Relays can be used for controlling remote operator with Us=208-204 V AC.

Control wiring on push-in clamps.

Cannot be used with the PXR10 NZM-AX electronic trip.

Pollution degree

2

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Rated impulse withstand voltage (Uimp)

4 kV AC

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Switching capacity (reference value) - min

0.1 mA / 0.1 VDC

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Type

Accessory

Relay module

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

PXR20(25) NZM2(-4)-..X…

PXR20(25) NZM3(-4)-..X…

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Rated operational current

1 A (230 V AC-1, relay contacts)

1 A (24 V DC-1, relay outputs)

1 A (24 V AC-1, relay contacts)

1 A (110 V AC-1, relay contacts)

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Rated insulation voltage (Ui)

250 V

Document Links

Datasheet