NZM2/3-XA48AC/DC-PI

A shunt release,48AC/DC,Push-In

Trade Price

£108.70

Per

1

Unit

EACH

Pack Quantity

NZM2/3-XA48AC/DC-PI
NZM2/3-XA48AC/DC-PI
NZM2/3-XA48AC/DC-PI
NZM2/3-XA48AC/DC-PI

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Shunt release for NZM2/3, 48AC/DC, Push-in terminals

Technical Specifications

Product Length/Depth

115 mm

Product Height

65 mm

Product Width

75 mm

Product Weight

0.08 kg

Compliances

UL/CSA

IEC

RoHS conform

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM2/3

Rated control supply voltage (Us) at AC, 50 Hz - min

48 V

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Suitable for

Off-load switch

Motor safety switch

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Rated control supply voltage (Us) at DC - min

48 V

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

Rated control supply voltage (Us) at AC, 50 Hz - max

48 V

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

Connection type

With push in terminal

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Special features

When the shunt release is live, contact with the circuit-breaker's main contacts on switching on is reliably prevented.

Shunt release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, untervoltage release NZM…-XU…, or relais modules NZM...-X2A...

Undelayed short-circuit release - min

0 A

Rated control supply voltage (Us) at AC, 60 Hz - min

48 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Rated control supply voltage (Us) at DC - max

48 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Rated control supply voltage

48 V AC/DC

Type

Accessory

Shunt release

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Rated control supply voltage (Us) at AC, 60 Hz - max

48 V

Used with

NZM3(-4), N(S)3(-4)

NZM2(-4), N(S)2(-4)

Number of contacts (normally open contacts)

0

Undelayed short-circuit release - max

0 A

Electric connection type

Screw connection

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Number of contacts (change-over contacts)

0

Voltage type

AC

Document Links

Datasheet