This Harmony XAC, yellow pendant station for hoist motor has 2-speed. This pendant station for hoist motor is designed for standard or medium-duty control circuit applications in your machines. It has 4 push buttons and 1 emergency stop with "raise", "lower", "left", "right" markings, with normally open and normally close contact. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It offers movement in 2 speeds (low and high) for each movements. Its wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product.
Range of product
Harmony XAC
Product or component type
Pendant control station
Device short name
XACA
Control station type
Double insulated
Enclosure material
Polypropylene
Electrical circuit type
Control circuit
Enclosure type
Complete ready for use
Control station application
Control of 2-speed hoist motor
Control station composition
4 push-buttons + 1 emergency stop
Control button type
First push-button 1 NC + 2 NO raise, slow-fast Second push-button 1 NC + 2 NO lower, slow-fast Stop push-button Ø 40 mm 1 NC latching Fourth push-button 1 NC + 2 NO left, slow-fast Third push-button 1 NC + 2 NO right, slow-fast
Product compatibility
ZB2BE102 for emergency stop XENG1191 for each direction
Mechanical interlocking
With mechanical interlocking between pairs
Control station colour
Yellow
Connections - terminals
Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
standards
IEC 60204-32 IEC 60947-5-1 CSA C22.2 No 14 UL 508
product certifications
CCC GOST
Protective treatment
TH
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn conforming to IEC 60068-2-27
Overvoltage category
Class II conforming to IEC 61140
IP degree of protection
IP65 conforming to IEC 60529
IK degree of protection
IK08 conforming to IEC 62262
Mechanical durability
1000000 cycles
Cable entry
Rubber sleeve with stepped entry 8…26 mm
Contact code designation
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
600 V (pollution degree 3)
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
contact operation
Staggered Slow-break
Maximum resistance across terminals
25 MOhm
Operating force
18 N push-button 8 N emergency stop
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Rated operational power in W
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Terminals description ISO n°1
(33-34)NO_CL (13-14)NO (21-22)NC
Terminals description ISO n°2
(11-12)NC
Terminal identifier
(13-14)NO (11-12)NC
Net weight
0.675 kg
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
10.0 cm
Package 1 Width
11.0 cm
Package 1 Length
52.0 cm
Package 1 Weight
895.0 g
Unit Type of Package 2
S04
Number of Units in Package 2
6
Package 2 Height
30.0 cm
Package 2 Width
40.0 cm
Package 2 Length
60.0 cm
Package 2 Weight
6.121 kg
Warranty
18 months