RM35TF30

MLTFNC PHCTRL220 480VAPHFAIL ROT

Trade Price

£238.97

Per

1

Unit

EA

Pack Quantity

1

RM35TF30
RM35TF30
RM35TF30
RM35TF30

Information

This Harmony RM35-T multi function control relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Technical Specifications

Range of produc

Harmony Control Relays

Relay type

Multifunction control relay

Product or component type

3-phase control relay

Product specific application

For 3-phase supply

Relay name

RM35TF

Relay monitored parameters

Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry

time delay

Adjustable 0.1...10 s, +/- 10 % of the full scale value

Switching capacity in VA

1250 VA

Measurement range

220...480 V voltage AC

Contacts type and composition

2 C/O

[Uc] control circuit voltage

220...480 V

Reset time

1500 ms at 480 V

Maximum switching voltage

250 V AC 250 V DC

Minimum switching current

10 mA at 5 V DC

Maximum switching current

5 A AC 5 A DC

Supply voltage limits

194…528 V AC, 3 phases

Control circuit voltage limits

- 12 % + 10 % Un

Power consumption in VA

0…22 VA at 400 V AC 50 Hz

Voltage detection threshold

< 194 V

control circuit frequency

50...60 Hz +/- 10 %

Output contacts

2 C/O

Nominal output current

5 A

Measurement voltage limits

176…528 V AC

Hysteresis

2 %

delay at power up

650 ms

Maximum measuring cycle

140 ms measurement cycle as true rms value

Threshold adjustment voltage

-20...-2 % in the range 380...480 V AC 2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+20 % in the range 220...440 V AC +2...+10 % in the range 480 V AC

Voltage range

220...480 V phase to phase

Adjustment of asymmetry threshold

5...15 % of Un selected

Repeat accuracy

0.3 % for time delay 0.5 % for input and measurement circuit

Measurement error

< 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation

Response time

< 200 ms (in the event of a fault)

Marking

CE

Overvoltage category

III conforming to IEC 60664-1

Insulation resistance

> 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1

[Ui] rated insulation voltage

400 V conforming to IEC 60664-1

Supply frequency

50/60 Hz +/- 10 %

Operating position

Any position without derating

Connections - terminals

Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Tightening torque

0.6…1 N.m conforming to IEC 60947-1

Housing material

Self-extinguishing plastic

Local signalling

LED (green) for power ON LED (yellow) for relay ON LED (yellow) for fault

Mounting support

35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability

100000 cycles

Mechanical durability

30000000 cycles

Operating rate

<= 360 operations/hour full load

Utilisation category

AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conf

Document Links

Datasheet

Technical Data