All Companies

Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3VA22250 A
3VA2225-0HL32-0AA0
3VA2225-0HL32-0AA0
3VA2225-0HL32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5... 10 x In busbar connection

£1,137.87

EACH

Datasheet
3VA2225-0HL42-0AA0
3VA2225-0HL42-0AA0
3VA2225-0HL42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5... 10 x In neutral protection adjustable(OFF 50% 100%) busbar connection

£1,547.49

EACH

Datasheet
3VA2225-0HM32-0AA0
3VA2225-0HM32-0AA0
3VA2225-0HM32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5... 10 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s busbar connection

£1,326.42

EACH

Datasheet
3VA2225-0HM42-0AA0
3VA2225-0HM42-0AA0
3VA2225-0HM42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A ... 250A short circuit protection Ii=1,5... 10 x In neutral protection adjustable(OFF 50% 100%) ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s

£1,716.54

EACH

Datasheet
3VA2225-0HN32-0AA0
3VA2225-0HN32-0AA0
3VA2225-0HN32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5...10xIr, Ii=10xIn busbar connection

£1,183.38

EACH

Datasheet
3VA2225-0HN32-0AF0
3VA2225-0HN32-0AF0
3VA2225-0HN32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5...10xIr, Ii=10xIn busbar connection circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5...10xIr, 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,215.59

EACH

Datasheet
3VA2225-0HN42-0AA0
3VA2225-0HN42-0AA0
3VA2225-0HN42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5...10xIr, Ii=10xIn neutral protection adjustable(OFF 50% 100%) busbar connection

£1,580.01

EACH

Datasheet
3VA2225-0KP32-0AA0
3VA2225-0KP32-0AA0
3VA2225-0KP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6...10xIn, Ii=1,5...10xIn busbar connection

£1,645.02

EACH

Datasheet
3VA2225-0KP42-0AA0
3VA2225-0KP42-0AA0
3VA2225-0KP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6...10xIn, Ii=1,5...10xIn neutral protection adjustable(OFF up to 100%) busbar connection

£2,048.16

EACH

Datasheet
3VA2225-0KQ32-0AA0
3VA2225-0KQ32-0AA0
3VA2225-0KQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6...10xIn, Ii=1,5...10xIn busbar connection

£1,768.56

EACH

Datasheet
3VA2225-0KQ42-0AA0
3VA2225-0KQ42-0AA0
3VA2225-0KQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=0,6...10xIn, Ii=1,5...10xIn neutral protection adjustable(OFF up to 100%) busbar connection

£2,152.19

EACH

Datasheet
3VA2225-5HL32-0AA0
3VA2225-5HL32-0AA0
3VA2225-5HL32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit

£716.48

EACH

Datasheet
3VA2225-5HL32-0AB0
3VA2225-5HL32-0AB0
3VA2225-5HL32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£809.39

EACH

Datasheet
3VA2225-5HL32-0AC0
3VA2225-5HL32-0AC0
3VA2225-5HL32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£837.11

EACH

Datasheet
3VA2225-5HL32-0AD0
3VA2225-5HL32-0AD0
3VA2225-5HL32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£809.39

EACH

Datasheet
3VA2225-5HL32-0AE0
3VA2225-5HL32-0AE0
3VA2225-5HL32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£822.78

EACH

Datasheet
3VA2225-5HL32-0AF0
3VA2225-5HL32-0AF0
3VA2225-5HL32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£837.11

EACH

Datasheet
3VA2225-5HL32-0AG0
3VA2225-5HL32-0AG0
3VA2225-5HL32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£809.39

EACH

Datasheet
3VA2225-5HL32-0AH0
3VA2225-5HL32-0AH0
3VA2225-5HL32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£809.39

EACH

Datasheet
3VA2225-5HL32-0AJ0
3VA2225-5HL32-0AJ0
3VA2225-5HL32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£836.16

EACH

Datasheet
3VA2225-5HL32-0AL0
3VA2225-5HL32-0AL0
3VA2225-5HL32-0AL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£836.16

EACH

Datasheet
3VA2225-5HL32-0BA0
3VA2225-5HL32-0BA0
3VA2225-5HL32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£836.16

EACH

Datasheet
3VA2225-5HL32-0BB0
3VA2225-5HL32-0BB0
3VA2225-5HL32-0BB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HP

£896.35

EACH

Datasheet
3VA2225-5HL32-0BC0
3VA2225-5HL32-0BC0
3VA2225-5HL32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0BH0
3VA2225-5HL32-0BH0
3VA2225-5HL32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£882.98

EACH

Datasheet
3VA2225-5HL32-0BL0
3VA2225-5HL32-0BL0
3VA2225-5HL32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£977.81

EACH

Datasheet
3VA2225-5HL32-0CA0
3VA2225-5HL32-0CA0
3VA2225-5HL32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£836.16

EACH

Datasheet
3VA2225-5HL32-0CC0
3VA2225-5HL32-0CC0
3VA2225-5HL32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0CH0
3VA2225-5HL32-0CH0
3VA2225-5HL32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£882.98

EACH

Datasheet
3VA2225-5HL32-0CL0
3VA2225-5HL32-0CL0
3VA2225-5HL32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£977.81

EACH

Datasheet
3VA2225-5HL32-0DA0
3VA2225-5HL32-0DA0
3VA2225-5HL32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£836.16

EACH

Datasheet
3VA2225-5HL32-0DC0
3VA2225-5HL32-0DC0
3VA2225-5HL32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0DF0
3VA2225-5HL32-0DF0
3VA2225-5HL32-0DF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection II=1.5...10xIN nut keeper kit undervoltage release 208-230V AC 50/60Hz 1 auxiliary switch 1 trip alarm switch

£876.28

EACH

Datasheet
3VA2225-5HL32-0DG0
3VA2225-5HL32-0DG0
3VA2225-5HL32-0DG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut undervoltage release 208-230V AC 50/60Hz accessory for: 3VA1 1 auxiliary switch changeover H 1 trip alarm switch changeover

£903.05

EACH

Datasheet
3VA2225-5HL32-0DH0
3VA2225-5HL32-0DH0
3VA2225-5HL32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£882.98

EACH

Datasheet
3VA2225-5HL32-0DL0
3VA2225-5HL32-0DL0
3VA2225-5HL32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£977.81

EACH

Datasheet
3VA2225-5HL32-0HA0
3VA2225-5HL32-0HA0
3VA2225-5HL32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£816.08

EACH

Datasheet
3VA2225-5HL32-0HC0
3VA2225-5HL32-0HC0
3VA2225-5HL32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£849.53

EACH

Datasheet
3VA2225-5HL32-0HH0
3VA2225-5HL32-0HH0
3VA2225-5HL32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0HL0
3VA2225-5HL32-0HL0
3VA2225-5HL32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£896.35

EACH

Datasheet
3VA2225-5HL32-0JA0
3VA2225-5HL32-0JA0
3VA2225-5HL32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£816.08

EACH

Datasheet
3VA2225-5HL32-0JC0
3VA2225-5HL32-0JC0
3VA2225-5HL32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£849.53

EACH

Datasheet
3VA2225-5HL32-0JH0
3VA2225-5HL32-0JH0
3VA2225-5HL32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0JL0
3VA2225-5HL32-0JL0
3VA2225-5HL32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£896.35

EACH

Datasheet
3VA2225-5HL32-0KA0
3VA2225-5HL32-0KA0
3VA2225-5HL32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£816.08

EACH

Datasheet
3VA2225-5HL32-0KC0
3VA2225-5HL32-0KC0
3VA2225-5HL32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£849.53

EACH

Datasheet
3VA2225-5HL32-0KG0
3VA2225-5HL32-0KG0
3VA2225-5HL32-0KG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 1 auxiliary switch HP 1 trip alarm switch HP

£869.60

EACH

Datasheet
3VA2225-5HL32-0KH0
3VA2225-5HL32-0KH0
3VA2225-5HL32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£869.60

EACH

Datasheet
3VA2225-5HL32-0KL0
3VA2225-5HL32-0KL0
3VA2225-5HL32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£896.35

EACH

Datasheet
3VA2225-5HL42-0AA0
3VA2225-5HL42-0AA0
3VA2225-5HL42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£952.46

EACH

Datasheet
3VA2225-5HL42-0AB0
3VA2225-5HL42-0AB0
3VA2225-5HL42-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP

£1,050.22

EACH

Datasheet
3VA2225-5HL42-0AC0
3VA2225-5HL42-0AC0
3VA2225-5HL42-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ

£1,036.83

EACH

Datasheet
3VA2225-5HL42-0AD0
3VA2225-5HL42-0AD0
3VA2225-5HL42-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 3 auxiliary switches HQ

£1,050.22

EACH

Datasheet
3VA2225-5HL42-0AE0
3VA2225-5HL42-0AE0
3VA2225-5HL42-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 4 auxiliary switches HQ

£1,118.49

EACH

Datasheet
3VA2225-5HL42-0AF0
3VA2225-5HL42-0AF0
3VA2225-5HL42-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,036.83

EACH

Datasheet
3VA2225-5HL42-0AG0
3VA2225-5HL42-0AG0
3VA2225-5HL42-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,050.22

EACH

Datasheet
3VA2225-5HL42-0AH0
3VA2225-5HL42-0AH0
3VA2225-5HL42-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,050.22

EACH

Datasheet
3VA2225-5HL42-0AJ0
3VA2225-5HL42-0AJ0
3VA2225-5HL42-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,076.96

EACH

Datasheet
3VA2225-5HL42-0BA0
3VA2225-5HL42-0BA0
3VA2225-5HL42-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC

£1,076.96

EACH

Datasheet
3VA2225-5HL42-0BC0
3VA2225-5HL42-0BC0
3VA2225-5HL42-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0BE0
3VA2225-5HL42-0BE0
3VA2225-5HL42-0BE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 4 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-5HL42-0BH0
3VA2225-5HL42-0BH0
3VA2225-5HL42-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2225-5HL42-0BL0
3VA2225-5HL42-0BL0
3VA2225-5HL42-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2225-5HL42-0CA0
3VA2225-5HL42-0CA0
3VA2225-5HL42-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,076.96

EACH

Datasheet
3VA2225-5HL42-0CC0
3VA2225-5HL42-0CC0
3VA2225-5HL42-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0CH0
3VA2225-5HL42-0CH0
3VA2225-5HL42-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2225-5HL42-0CL0
3VA2225-5HL42-0CL0
3VA2225-5HL42-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2225-5HL42-0DA0
3VA2225-5HL42-0DA0
3VA2225-5HL42-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,076.96

EACH

Datasheet
3VA2225-5HL42-0DC0
3VA2225-5HL42-0DC0
3VA2225-5HL42-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0DH0
3VA2225-5HL42-0DH0
3VA2225-5HL42-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2225-5HL42-0DL0
3VA2225-5HL42-0DL0
3VA2225-5HL42-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2225-5HL42-0HA0
3VA2225-5HL42-0HA0
3VA2225-5HL42-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2225-5HL42-0HC0
3VA2225-5HL42-0HC0
3VA2225-5HL42-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-5HL42-0HH0
3VA2225-5HL42-0HH0
3VA2225-5HL42-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0HL0
3VA2225-5HL42-0HL0
3VA2225-5HL42-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-5HL42-0JA0
3VA2225-5HL42-0JA0
3VA2225-5HL42-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2225-5HL42-0JC0
3VA2225-5HL42-0JC0
3VA2225-5HL42-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-5HL42-0JH0
3VA2225-5HL42-0JH0
3VA2225-5HL42-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0JL0
3VA2225-5HL42-0JL0
3VA2225-5HL42-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-5HL42-0KA0
3VA2225-5HL42-0KA0
3VA2225-5HL42-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,111.46

EACH

Datasheet
3VA2225-5HL42-0KB0
3VA2225-5HL42-0KB0
3VA2225-5HL42-0KB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0KC0
3VA2225-5HL42-0KC0
3VA2225-5HL42-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-5HL42-0KH0
3VA2225-5HL42-0KH0
3VA2225-5HL42-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2225-5HL42-0KL0
3VA2225-5HL42-0KL0
3VA2225-5HL42-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-5HM32-0AA0
3VA2225-5HM32-0AA0
3VA2225-5HM32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£895.17

EACH

Datasheet
3VA2225-5HM32-0DA0
3VA2225-5HM32-0DA0
3VA2225-5HM32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1

£1,039.72

EACH

Datasheet
3VA2225-5HM42-0AA0
3VA2225-5HM42-0AA0
3VA2225-5HM42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,132.32

EACH

Datasheet
3VA2225-5HM42-0DF0
3VA2225-5HM42-0DF0
3VA2225-5HM42-0DF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,297.71

EACH

Datasheet
3VA2225-5HN32-0AA0
3VA2225-5HN32-0AA0
3VA2225-5HN32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£909.94

EACH

Datasheet
3VA2225-5HN32-0AB0
3VA2225-5HN32-0AB0
3VA2225-5HN32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£849.53

EACH

Datasheet
3VA2225-5HN32-0AC0
3VA2225-5HN32-0AC0
3VA2225-5HN32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£836.16

EACH

Datasheet
3VA2225-5HN32-0AD0
3VA2225-5HN32-0AD0
3VA2225-5HN32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£849.53

EACH

Datasheet
3VA2225-5HN32-0AE0
3VA2225-5HN32-0AE0
3VA2225-5HN32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£862.90

EACH

Datasheet
3VA2225-5HN32-0AF0
3VA2225-5HN32-0AF0
3VA2225-5HN32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£836.16

EACH

Datasheet
3VA2225-5HN32-0AG0
3VA2225-5HN32-0AG0
3VA2225-5HN32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£849.53

EACH

Datasheet
3VA2225-5HN32-0AH0
3VA2225-5HN32-0AH0
3VA2225-5HN32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£849.53

EACH

Datasheet
3VA2225-5HN32-0AJ0
3VA2225-5HN32-0AJ0
3VA2225-5HN32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£876.28

EACH

Datasheet
3VA2225-5HN32-0BA0
3VA2225-5HN32-0BA0
3VA2225-5HN32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£876.28

EACH

Datasheet
3VA2225-5HN32-0BC0
3VA2225-5HN32-0BC0
3VA2225-5HN32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0BH0
3VA2225-5HN32-0BH0
3VA2225-5HN32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£943.18

EACH

Datasheet
3VA2225-5HN32-0BL0
3VA2225-5HN32-0BL0
3VA2225-5HN32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£969.93

EACH

Datasheet
3VA2225-5HN32-0CA0
3VA2225-5HN32-0CA0
3VA2225-5HN32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£876.28

EACH

Datasheet
3VA2225-5HN32-0CC0
3VA2225-5HN32-0CC0
3VA2225-5HN32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0CH0
3VA2225-5HN32-0CH0
3VA2225-5HN32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£943.18

EACH

Datasheet
3VA2225-5HN32-0CL0
3VA2225-5HN32-0CL0
3VA2225-5HN32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£969.93

EACH

Datasheet
3VA2225-5HN32-0DA0
3VA2225-5HN32-0DA0
3VA2225-5HN32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£876.28

EACH

Datasheet
3VA2225-5HN32-0DC0
3VA2225-5HN32-0DC0
3VA2225-5HN32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0DH0
3VA2225-5HN32-0DH0
3VA2225-5HN32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£943.18

EACH

Datasheet
3VA2225-5HN32-0DL0
3VA2225-5HN32-0DL0
3VA2225-5HN32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£969.93

EACH

Datasheet
3VA2225-5HN32-0HA0
3VA2225-5HN32-0HA0
3VA2225-5HN32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£856.23

EACH

Datasheet
3VA2225-5HN32-0HC0
3VA2225-5HN32-0HC0
3VA2225-5HN32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£896.35

EACH

Datasheet
3VA2225-5HN32-0HH0
3VA2225-5HN32-0HH0
3VA2225-5HN32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0HL0
3VA2225-5HN32-0HL0
3VA2225-5HN32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£949.87

EACH

Datasheet
3VA2225-5HN32-0JA0
3VA2225-5HN32-0JA0
3VA2225-5HN32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£856.23

EACH

Datasheet
3VA2225-5HN32-0JC0
3VA2225-5HN32-0JC0
3VA2225-5HN32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£896.35

EACH

Datasheet
3VA2225-5HN32-0JH0
3VA2225-5HN32-0JH0
3VA2225-5HN32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0JL0
3VA2225-5HN32-0JL0
3VA2225-5HN32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£949.87

EACH

Datasheet
3VA2225-5HN32-0KA0
3VA2225-5HN32-0KA0
3VA2225-5HN32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£856.23

EACH

Datasheet
3VA2225-5HN32-0KC0
3VA2225-5HN32-0KC0
3VA2225-5HN32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£896.35

EACH

Datasheet
3VA2225-5HN32-0KF0
3VA2225-5HN32-0KF0
3VA2225-5HN32-0KF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V shunt trip left 208-277V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£903.05

EACH

Datasheet
3VA2225-5HN32-0KH0
3VA2225-5HN32-0KH0
3VA2225-5HN32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£977.81

EACH

Datasheet
3VA2225-5HN32-0KK0
3VA2225-5HN32-0KK0
3VA2225-5HN32-0KK0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£977.81

EACH

Datasheet
3VA2225-5HN32-0KL0
3VA2225-5HN32-0KL0
3VA2225-5HN32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£949.87

EACH

Datasheet
3VA2225-5HN32-0LE0
3VA2225-5HN32-0LE0
3VA2225-5HN32-0LE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 4 AUXILIARY SWITCH CHANGEOVER H

£1,023.44

EACH

Datasheet
3VA2225-5HN32-0LF0
3VA2225-5HN32-0LF0
3VA2225-5HN32-0LF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£981.81

EACH

Datasheet
3VA2225-5HN42-0AA0
3VA2225-5HN42-0AA0
3VA2225-5HN42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,004.96

EACH

Datasheet
3VA2225-5HN42-0AB0
3VA2225-5HN42-0AB0
3VA2225-5HN42-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP

£1,083.66

EACH

Datasheet
3VA2225-5HN42-0AC0
3VA2225-5HN42-0AC0
3VA2225-5HN42-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ

£1,125.53

EACH

Datasheet
3VA2225-5HN42-0AD0
3VA2225-5HN42-0AD0
3VA2225-5HN42-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 3 auxiliary switches HQ

£1,083.66

EACH

Datasheet
3VA2225-5HN42-0AE0
3VA2225-5HN42-0AE0
3VA2225-5HN42-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 4 auxiliary switches HQ

£1,103.71

EACH

Datasheet
3VA2225-5HN42-0AF0
3VA2225-5HN42-0AF0
3VA2225-5HN42-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,125.53

EACH

Datasheet
3VA2225-5HN42-0AG0
3VA2225-5HN42-0AG0
3VA2225-5HN42-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,083.66

EACH

Datasheet
3VA2225-5HN42-0AH0
3VA2225-5HN42-0AH0
3VA2225-5HN42-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,083.66

EACH

Datasheet
3VA2225-5HN42-0AJ0
3VA2225-5HN42-0AJ0
3VA2225-5HN42-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,117.10

EACH

Datasheet
3VA2225-5HN42-0BA0
3VA2225-5HN42-0BA0
3VA2225-5HN42-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC

£1,117.10

EACH

Datasheet
3VA2225-5HN42-0BB0
3VA2225-5HN42-0BB0
3VA2225-5HN42-0BB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H

£1,170.38

EACH

Datasheet
3VA2225-5HN42-0BC0
3VA2225-5HN42-0BC0
3VA2225-5HN42-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0BH0
3VA2225-5HN42-0BH0
3VA2225-5HN42-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,170.61

EACH

Datasheet
3VA2225-5HN42-0BL0
3VA2225-5HN42-0BL0
3VA2225-5HN42-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-5HN42-0CA0
3VA2225-5HN42-0CA0
3VA2225-5HN42-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,117.10

EACH

Datasheet
3VA2225-5HN42-0CC0
3VA2225-5HN42-0CC0
3VA2225-5HN42-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0CH0
3VA2225-5HN42-0CH0
3VA2225-5HN42-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,170.61

EACH

Datasheet
3VA2225-5HN42-0CL0
3VA2225-5HN42-0CL0
3VA2225-5HN42-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-5HN42-0DA0
3VA2225-5HN42-0DA0
3VA2225-5HN42-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,117.10

EACH

Datasheet
3VA2225-5HN42-0DC0
3VA2225-5HN42-0DC0
3VA2225-5HN42-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0DH0
3VA2225-5HN42-0DH0
3VA2225-5HN42-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,170.61

EACH

Datasheet
3VA2225-5HN42-0DL0
3VA2225-5HN42-0DL0
3VA2225-5HN42-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-5HN42-0HA0
3VA2225-5HN42-0HA0
3VA2225-5HN42-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,097.04

EACH

Datasheet
3VA2225-5HN42-0HC0
3VA2225-5HN42-0HC0
3VA2225-5HN42-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,137.16

EACH

Datasheet
3VA2225-5HN42-0HH0
3VA2225-5HN42-0HH0
3VA2225-5HN42-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0HL0
3VA2225-5HN42-0HL0
3VA2225-5HN42-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,184.00

EACH

Datasheet
3VA2225-5HN42-0JA0
3VA2225-5HN42-0JA0
3VA2225-5HN42-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,097.04

EACH

Datasheet
3VA2225-5HN42-0JC0
3VA2225-5HN42-0JC0
3VA2225-5HN42-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,137.16

EACH

Datasheet
3VA2225-5HN42-0JH0
3VA2225-5HN42-0JH0
3VA2225-5HN42-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0JL0
3VA2225-5HN42-0JL0
3VA2225-5HN42-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,184.00

EACH

Datasheet
3VA2225-5HN42-0KA0
3VA2225-5HN42-0KA0
3VA2225-5HN42-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,097.04

EACH

Datasheet
3VA2225-5HN42-0KB0
3VA2225-5HN42-0KB0
3VA2225-5HN42-0KB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF,50%,100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HP

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0KC0
3VA2225-5HN42-0KC0
3VA2225-5HN42-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,137.16

EACH

Datasheet
3VA2225-5HN42-0KH0
3VA2225-5HN42-0KH0
3VA2225-5HN42-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,157.23

EACH

Datasheet
3VA2225-5HN42-0KL0
3VA2225-5HN42-0KL0
3VA2225-5HN42-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,184.00

EACH

Datasheet
3VA2225-5JP32-0AA0
3VA2225-5JP32-0AA0
3VA2225-5JP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,166.46

EACH

Datasheet
3VA2225-5JP32-0AB0
3VA2225-5JP32-0AB0
3VA2225-5JP32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP

£1,163.92

EACH

Datasheet
3VA2225-5JP32-0AC0
3VA2225-5JP32-0AC0
3VA2225-5JP32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ

£1,150.55

EACH

Datasheet
3VA2225-5JP32-0AD0
3VA2225-5JP32-0AD0
3VA2225-5JP32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 3 auxiliary switches HQ

£1,163.92

EACH

Datasheet
3VA2225-5JP32-0AE0
3VA2225-5JP32-0AE0
3VA2225-5JP32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 4 auxiliary switches HQ

£1,184.00

EACH

Datasheet
3VA2225-5JP32-0AF0
3VA2225-5JP32-0AF0
3VA2225-5JP32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,150.55

EACH

Datasheet
3VA2225-5JP32-0AG0
3VA2225-5JP32-0AG0
3VA2225-5JP32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,163.92

EACH

Datasheet
3VA2225-5JP32-0AH0
3VA2225-5JP32-0AH0
3VA2225-5JP32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,163.92

EACH

Datasheet
3VA2225-5JP32-0AJ0
3VA2225-5JP32-0AJ0
3VA2225-5JP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,259.17

EACH

Datasheet
3VA2225-5JP32-0BA0
3VA2225-5JP32-0BA0
3VA2225-5JP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC

£1,259.17

EACH

Datasheet
3VA2225-5JP32-0BC0
3VA2225-5JP32-0BC0
3VA2225-5JP32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0BH0
3VA2225-5JP32-0BH0
3VA2225-5JP32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,244.20

EACH

Datasheet
3VA2225-5JP32-0BL0
3VA2225-5JP32-0BL0
3VA2225-5JP32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2225-5JP32-0CA0
3VA2225-5JP32-0CA0
3VA2225-5JP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,259.17

EACH

Datasheet
3VA2225-5JP32-0CC0
3VA2225-5JP32-0CC0
3VA2225-5JP32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0CH0
3VA2225-5JP32-0CH0
3VA2225-5JP32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,244.20

EACH

Datasheet
3VA2225-5JP32-0CL0
3VA2225-5JP32-0CL0
3VA2225-5JP32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2225-5JP32-0DA0
3VA2225-5JP32-0DA0
3VA2225-5JP32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,259.17

EACH

Datasheet
3VA2225-5JP32-0DC0
3VA2225-5JP32-0DC0
3VA2225-5JP32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0DH0
3VA2225-5JP32-0DH0
3VA2225-5JP32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,244.20

EACH

Datasheet
3VA2225-5JP32-0DL0
3VA2225-5JP32-0DL0
3VA2225-5JP32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2225-5JP32-0HA0
3VA2225-5JP32-0HA0
3VA2225-5JP32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,170.61

EACH

Datasheet
3VA2225-5JP32-0HC0
3VA2225-5JP32-0HC0
3VA2225-5JP32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,273.25

EACH

Datasheet
3VA2225-5JP32-0HH0
3VA2225-5JP32-0HH0
3VA2225-5JP32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0HL0
3VA2225-5JP32-0HL0
3VA2225-5JP32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,250.87

EACH

Datasheet
3VA2225-5JP32-0JA0
3VA2225-5JP32-0JA0
3VA2225-5JP32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,170.61

EACH

Datasheet
3VA2225-5JP32-0JC0
3VA2225-5JP32-0JC0
3VA2225-5JP32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,273.25

EACH

Datasheet
3VA2225-5JP32-0JH0
3VA2225-5JP32-0JH0
3VA2225-5JP32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0JL0
3VA2225-5JP32-0JL0
3VA2225-5JP32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,250.87

EACH

Datasheet
3VA2225-5JP32-0KA0
3VA2225-5JP32-0KA0
3VA2225-5JP32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,170.61

EACH

Datasheet
3VA2225-5JP32-0KC0
3VA2225-5JP32-0KC0
3VA2225-5JP32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,273.25

EACH

Datasheet
3VA2225-5JP32-0KH0
3VA2225-5JP32-0KH0
3VA2225-5JP32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,230.82

EACH

Datasheet
3VA2225-5JP32-0KL0
3VA2225-5JP32-0KL0
3VA2225-5JP32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,250.87

EACH

Datasheet
3VA2225-5JP32-0LL0
3VA2225-5JP32-0LL0
3VA2225-5JP32-0LL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=250A UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,411.50

EACH

Datasheet
3VA2225-5JP42-0AA0
3VA2225-5JP42-0AA0
3VA2225-5JP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,369.65

EACH

Datasheet
3VA2225-5JP42-0AG0
3VA2225-5JP42-0AG0
3VA2225-5JP42-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,401.12

EACH

Datasheet
3VA2225-5JP42-0AJ0
3VA2225-5JP42-0AJ0
3VA2225-5JP42-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,434.48

EACH

Datasheet
3VA2225-5JP42-0DF0
3VA2225-5JP42-0DF0
3VA2225-5JP42-0DF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,464.93

EACH

Datasheet
3VA2225-5JP42-0HC0
3VA2225-5JP42-0HC0
3VA2225-5JP42-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,444.88

EACH

Datasheet
3VA2225-5JP42-0KH0
3VA2225-5JP42-0KH0
3VA2225-5JP42-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,458.25

EACH

Datasheet
3VA2225-5JP42-0KL0
3VA2225-5JP42-0KL0
3VA2225-5JP42-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,495.48

EACH

Datasheet
3VA2225-5JQ32-0AA0
3VA2225-5JQ32-0AA0
3VA2225-5JQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,291.14

EACH

Datasheet
3VA2225-5JQ32-0AB0
3VA2225-5JQ32-0AB0
3VA2225-5JQ32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP

£1,357.91

EACH

Datasheet
3VA2225-5JQ32-0AC0
3VA2225-5JQ32-0AC0
3VA2225-5JQ32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ

£1,344.53

EACH

Datasheet
3VA2225-5JQ32-0AD0
3VA2225-5JQ32-0AD0
3VA2225-5JQ32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ

£1,357.91

EACH

Datasheet
3VA2225-5JQ32-0AE0
3VA2225-5JQ32-0AE0
3VA2225-5JQ32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 4 auxiliary switches HQ

£1,371.29

EACH

Datasheet
3VA2225-5JQ32-0AF0
3VA2225-5JQ32-0AF0
3VA2225-5JQ32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2225-5JQ32-0AG0
3VA2225-5JQ32-0AG0
3VA2225-5JQ32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,357.91

EACH

Datasheet
3VA2225-5JQ32-0AH0
3VA2225-5JQ32-0AH0
3VA2225-5JQ32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,357.91

EACH

Datasheet
3VA2225-5JQ32-0AJ0
3VA2225-5JQ32-0AJ0
3VA2225-5JQ32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,384.67

EACH

Datasheet
3VA2225-5JQ32-0AK0
3VA2225-5JQ32-0AK0
3VA2225-5JQ32-0AK0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,361.20

EACH

Datasheet
3VA2225-5JQ32-0BA0
3VA2225-5JQ32-0BA0
3VA2225-5JQ32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC

£1,384.67

EACH

Datasheet
3VA2225-5JQ32-0BC0
3VA2225-5JQ32-0BC0
3VA2225-5JQ32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0BH0
3VA2225-5JQ32-0BH0
3VA2225-5JQ32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2225-5JQ32-0BL0
3VA2225-5JQ32-0BL0
3VA2225-5JQ32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,464.93

EACH

Datasheet
3VA2225-5JQ32-0CA0
3VA2225-5JQ32-0CA0
3VA2225-5JQ32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,384.67

EACH

Datasheet
3VA2225-5JQ32-0CC0
3VA2225-5JQ32-0CC0
3VA2225-5JQ32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0CH0
3VA2225-5JQ32-0CH0
3VA2225-5JQ32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2225-5JQ32-0CL0
3VA2225-5JQ32-0CL0
3VA2225-5JQ32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,464.93

EACH

Datasheet
3VA2225-5JQ32-0DA0
3VA2225-5JQ32-0DA0
3VA2225-5JQ32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,384.67

EACH

Datasheet
3VA2225-5JQ32-0DC0
3VA2225-5JQ32-0DC0
3VA2225-5JQ32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0DE0
3VA2225-5JQ32-0DE0
3VA2225-5JQ32-0DE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection ISD=0.6..10xIn, II=1.5..10xIn N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off IG=0.2...1xIn, TG=0.050,8S undervoltage release 208-230V AC 50/60Hz 4 auxiliary switches

£1,451.55

EACH

Datasheet
3VA2225-5JQ32-0DH0
3VA2225-5JQ32-0DH0
3VA2225-5JQ32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2225-5JQ32-0DL0
3VA2225-5JQ32-0DL0
3VA2225-5JQ32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,464.93

EACH

Datasheet
3VA2225-5JQ32-0HA0
3VA2225-5JQ32-0HA0
3VA2225-5JQ32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,364.61

EACH

Datasheet
3VA2225-5JQ32-0HC0
3VA2225-5JQ32-0HC0
3VA2225-5JQ32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,398.04

EACH

Datasheet
3VA2225-5JQ32-0HH0
3VA2225-5JQ32-0HH0
3VA2225-5JQ32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0HL0
3VA2225-5JQ32-0HL0
3VA2225-5JQ32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,444.88

EACH

Datasheet
3VA2225-5JQ32-0JA0
3VA2225-5JQ32-0JA0
3VA2225-5JQ32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,364.61

EACH

Datasheet
3VA2225-5JQ32-0JC0
3VA2225-5JQ32-0JC0
3VA2225-5JQ32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,398.04

EACH

Datasheet
3VA2225-5JQ32-0JH0
3VA2225-5JQ32-0JH0
3VA2225-5JQ32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0JL0
3VA2225-5JQ32-0JL0
3VA2225-5JQ32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,444.88

EACH

Datasheet
3VA2225-5JQ32-0KA0
3VA2225-5JQ32-0KA0
3VA2225-5JQ32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,364.61

EACH

Datasheet
3VA2225-5JQ32-0KC0
3VA2225-5JQ32-0KC0
3VA2225-5JQ32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,398.04

EACH

Datasheet
3VA2225-5JQ32-0KH0
3VA2225-5JQ32-0KH0
3VA2225-5JQ32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2225-5JQ32-0KL0
3VA2225-5JQ32-0KL0
3VA2225-5JQ32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,444.88

EACH

Datasheet
3VA2225-5JQ42-0AA0
3VA2225-5JQ42-0AA0
3VA2225-5JQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,590.88

EACH

Datasheet
3VA2225-5JQ42-0CH0
3VA2225-5JQ42-0CH0
3VA2225-5JQ42-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit UNDERVOLTAGE RELEASE 120-127 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,668.00

EACH

Datasheet
3VA2225-5JQ42-0DH0
3VA2225-5JQ42-0DH0
3VA2225-5JQ42-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, 50%, 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,672.31

EACH

Datasheet
3VA2225-5JQ42-0DJ0
3VA2225-5JQ42-0DJ0
3VA2225-5JQ42-0DJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, 50%, 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HP 1 trip alarm switch HP

£1,699.06

EACH

Datasheet
3VA2225-5JQ42-0HD0
3VA2225-5JQ42-0HD0
3VA2225-5JQ42-0HD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line SHUNT TRIP LEFT 24 V AC 50/60 HZ / 24-30 V DC ACCESSORY FOR 3 AUXILIARY SWITCH CHANGEOVER H

£1,651.53

EACH

Datasheet
3VA2225-5JQ42-0KL0
3VA2225-5JQ42-0KL0
3VA2225-5JQ42-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,677.55

EACH

Datasheet
3VA2225-5KP32-0AA0
3VA2225-5KP32-0AA0
3VA2225-5KP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,099.14

EACH

Datasheet
3VA2225-5KP32-0AB0
3VA2225-5KP32-0AB0
3VA2225-5KP32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP

£1,324.46

EACH

Datasheet
3VA2225-5KP32-0AC0
3VA2225-5KP32-0AC0
3VA2225-5KP32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ

£1,304.39

EACH

Datasheet
3VA2225-5KP32-0AD0
3VA2225-5KP32-0AD0
3VA2225-5KP32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 3 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2225-5KP32-0AE0
3VA2225-5KP32-0AE0
3VA2225-5KP32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 4 auxiliary switches HQ

£1,344.53

EACH

Datasheet
3VA2225-5KP32-0AF0
3VA2225-5KP32-0AF0
3VA2225-5KP32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,304.39

EACH

Datasheet
3VA2225-5KP32-0AG0
3VA2225-5KP32-0AG0
3VA2225-5KP32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,324.46

EACH

Datasheet
3VA2225-5KP32-0AH0
3VA2225-5KP32-0AH0
3VA2225-5KP32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,324.46

EACH

Datasheet
3VA2225-5KP32-0AJ0
3VA2225-5KP32-0AJ0
3VA2225-5KP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,357.91

EACH

Datasheet
3VA2225-5KP32-0BA0
3VA2225-5KP32-0BA0
3VA2225-5KP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC

£1,357.91

EACH

Datasheet
3VA2225-5KP32-0BC0
3VA2225-5KP32-0BC0
3VA2225-5KP32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0BH0
3VA2225-5KP32-0BH0
3VA2225-5KP32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,404.73

EACH

Datasheet
3VA2225-5KP32-0BL0
3VA2225-5KP32-0BL0
3VA2225-5KP32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2225-5KP32-0CA0
3VA2225-5KP32-0CA0
3VA2225-5KP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,357.91

EACH

Datasheet
3VA2225-5KP32-0CC0
3VA2225-5KP32-0CC0
3VA2225-5KP32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0CH0
3VA2225-5KP32-0CH0
3VA2225-5KP32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,404.73

EACH

Datasheet
3VA2225-5KP32-0CL0
3VA2225-5KP32-0CL0
3VA2225-5KP32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2225-5KP32-0DA0
3VA2225-5KP32-0DA0
3VA2225-5KP32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,357.91

EACH

Datasheet
3VA2225-5KP32-0DC0
3VA2225-5KP32-0DC0
3VA2225-5KP32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0DH0
3VA2225-5KP32-0DH0
3VA2225-5KP32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,404.73

EACH

Datasheet
3VA2225-5KP32-0DL0
3VA2225-5KP32-0DL0
3VA2225-5KP32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2225-5KP32-0HA0
3VA2225-5KP32-0HA0
3VA2225-5KP32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,406.91

EACH

Datasheet
3VA2225-5KP32-0HC0
3VA2225-5KP32-0HC0
3VA2225-5KP32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,371.29

EACH

Datasheet
3VA2225-5KP32-0HH0
3VA2225-5KP32-0HH0
3VA2225-5KP32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0HL0
3VA2225-5KP32-0HL0
3VA2225-5KP32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,411.43

EACH

Datasheet
3VA2225-5KP32-0JA0
3VA2225-5KP32-0JA0
3VA2225-5KP32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,406.91

EACH

Datasheet
3VA2225-5KP32-0JC0
3VA2225-5KP32-0JC0
3VA2225-5KP32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,371.29

EACH

Datasheet
3VA2225-5KP32-0JD0
3VA2225-5KP32-0JD0
3VA2225-5KP32-0JD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip left 110-127V AC 50/60Hz/DC 3 auxiliary switches

£1,384.67

EACH

Datasheet
3VA2225-5KP32-0JH0
3VA2225-5KP32-0JH0
3VA2225-5KP32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0JL0
3VA2225-5KP32-0JL0
3VA2225-5KP32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,411.43

EACH

Datasheet
3VA2225-5KP32-0KA0
3VA2225-5KP32-0KA0
3VA2225-5KP32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,406.91

EACH

Datasheet
3VA2225-5KP32-0KC0
3VA2225-5KP32-0KC0
3VA2225-5KP32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,371.29

EACH

Datasheet
3VA2225-5KP32-0KF0
3VA2225-5KP32-0KF0
3VA2225-5KP32-0KF0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,371.29

EACH

Datasheet
3VA2225-5KP32-0KH0
3VA2225-5KP32-0KH0
3VA2225-5KP32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,391.36

EACH

Datasheet
3VA2225-5KP32-0KL0
3VA2225-5KP32-0KL0
3VA2225-5KP32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,411.43

EACH

Datasheet
3VA2225-5KP42-0AA0
3VA2225-5KP42-0AA0
3VA2225-5KP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,472.83

EACH

Datasheet
3VA2225-5KP42-0AE0
3VA2225-5KP42-0AE0
3VA2225-5KP42-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 4 auxiliary switches HQ

£1,571.96

EACH

Datasheet
3VA2225-5KP42-0AJ0
3VA2225-5KP42-0AJ0
3VA2225-5KP42-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,585.34

EACH

Datasheet
3VA2225-5KP42-0AL0
3VA2225-5KP42-0AL0
3VA2225-5KP42-0AL0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,584.60

EACH

Datasheet
3VA2225-5KP42-0DK0
3VA2225-5KP42-0DK0
3VA2225-5KP42-0DK0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,652.24

EACH

Datasheet
3VA2225-5KP42-0KD0
3VA2225-5KP42-0KD0
3VA2225-5KP42-0KD0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 3 auxiliary switches HQ

£1,625.48

EACH

Datasheet
3VA2225-5KQ32-0AA0
3VA2225-5KQ32-0AA0
3VA2225-5KQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,416.51

EACH

Datasheet
3VA2225-5KQ42-0AA0
3VA2225-5KQ42-0AA0
3VA2225-5KQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,687.82

EACH

Datasheet
3VA2225-6HL32-0AA0
3VA2225-6HL32-0AA0
3VA2225-6HL32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit

£831.61

EACH

Datasheet
3VA2225-6HL32-0AB0
3VA2225-6HL32-0AB0
3VA2225-6HL32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£903.05

EACH

Datasheet
3VA2225-6HL32-0AC0
3VA2225-6HL32-0AC0
3VA2225-6HL32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£882.98

EACH

Datasheet
3VA2225-6HL32-0AD0
3VA2225-6HL32-0AD0
3VA2225-6HL32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£903.05

EACH

Datasheet
3VA2225-6HL32-0AE0
3VA2225-6HL32-0AE0
3VA2225-6HL32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£977.81

EACH

Datasheet
3VA2225-6HL32-0AF0
3VA2225-6HL32-0AF0
3VA2225-6HL32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£882.98

EACH

Datasheet
3VA2225-6HL32-0AG0
3VA2225-6HL32-0AG0
3VA2225-6HL32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£903.05

EACH

Datasheet
3VA2225-6HL32-0AH0
3VA2225-6HL32-0AH0
3VA2225-6HL32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£903.05

EACH

Datasheet
3VA2225-6HL32-0AJ0
3VA2225-6HL32-0AJ0
3VA2225-6HL32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£943.18

EACH

Datasheet
3VA2225-6HL32-0BA0
3VA2225-6HL32-0BA0
3VA2225-6HL32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£943.18

EACH

Datasheet
3VA2225-6HL32-0BC0
3VA2225-6HL32-0BC0
3VA2225-6HL32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0BH0
3VA2225-6HL32-0BH0
3VA2225-6HL32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£990.00

EACH

Datasheet
3VA2225-6HL32-0BL0
3VA2225-6HL32-0BL0
3VA2225-6HL32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,016.75

EACH

Datasheet
3VA2225-6HL32-0CA0
3VA2225-6HL32-0CA0
3VA2225-6HL32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£943.18

EACH

Datasheet
3VA2225-6HL32-0CC0
3VA2225-6HL32-0CC0
3VA2225-6HL32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0CH0
3VA2225-6HL32-0CH0
3VA2225-6HL32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£990.00

EACH

Datasheet
3VA2225-6HL32-0CL0
3VA2225-6HL32-0CL0
3VA2225-6HL32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,016.75

EACH

Datasheet
3VA2225-6HL32-0DA0
3VA2225-6HL32-0DA0
3VA2225-6HL32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£943.18

EACH

Datasheet
3VA2225-6HL32-0DB0
3VA2225-6HL32-0DB0
3VA2225-6HL32-0DB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H

£988.32

EACH

Datasheet
3VA2225-6HL32-0DC0
3VA2225-6HL32-0DC0
3VA2225-6HL32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0DH0
3VA2225-6HL32-0DH0
3VA2225-6HL32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£990.00

EACH

Datasheet
3VA2225-6HL32-0DK0
3VA2225-6HL32-0DK0
3VA2225-6HL32-0DK0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£994.82

EACH

Datasheet
3VA2225-6HL32-0DL0
3VA2225-6HL32-0DL0
3VA2225-6HL32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,016.75

EACH

Datasheet
3VA2225-6HL32-0HA0
3VA2225-6HL32-0HA0
3VA2225-6HL32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£963.73

EACH

Datasheet
3VA2225-6HL32-0HB0
3VA2225-6HL32-0HB0
3VA2225-6HL32-0HB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut SHUNT TRIP LEFT 24 V AC 50/60 HZ / 24-30 V DC ACCESSORY FOR 2 AUXILIARY SWITCH CHANGEOVER H

£973.00

EACH

Datasheet
3VA2225-6HL32-0HC0
3VA2225-6HL32-0HC0
3VA2225-6HL32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£956.54

EACH

Datasheet
3VA2225-6HL32-0HH0
3VA2225-6HL32-0HH0
3VA2225-6HL32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0HL0
3VA2225-6HL32-0HL0
3VA2225-6HL32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£996.69

EACH

Datasheet
3VA2225-6HL32-0JA0
3VA2225-6HL32-0JA0
3VA2225-6HL32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£963.73

EACH

Datasheet
3VA2225-6HL32-0JC0
3VA2225-6HL32-0JC0
3VA2225-6HL32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£956.54

EACH

Datasheet
3VA2225-6HL32-0JH0
3VA2225-6HL32-0JH0
3VA2225-6HL32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0JL0
3VA2225-6HL32-0JL0
3VA2225-6HL32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£996.69

EACH

Datasheet
3VA2225-6HL32-0KA0
3VA2225-6HL32-0KA0
3VA2225-6HL32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£963.73

EACH

Datasheet
3VA2225-6HL32-0KC0
3VA2225-6HL32-0KC0
3VA2225-6HL32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£956.54

EACH

Datasheet
3VA2225-6HL32-0KF0
3VA2225-6HL32-0KF0
3VA2225-6HL32-0KF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£949.30

EACH

Datasheet
3VA2225-6HL32-0KH0
3VA2225-6HL32-0KH0
3VA2225-6HL32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£976.62

EACH

Datasheet
3VA2225-6HL32-0KL0
3VA2225-6HL32-0KL0
3VA2225-6HL32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£996.69

EACH

Datasheet
3VA2225-6HL42-0AA0
3VA2225-6HL42-0AA0
3VA2225-6HL42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,066.11

EACH

Datasheet
3VA2225-6HL42-0AG0
3VA2225-6HL42-0AG0
3VA2225-6HL42-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,176.88

EACH

Datasheet
3VA2225-6HL42-0BF0
3VA2225-6HL42-0BF0
3VA2225-6HL42-0BF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,330.18

EACH

Datasheet
3VA2225-6HL42-0KH0
3VA2225-6HL42-0KH0
3VA2225-6HL42-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,237.50

EACH

Datasheet
3VA2225-6HM32-0AA0
3VA2225-6HM32-0AA0
3VA2225-6HM32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,002.60

EACH

Datasheet
3VA2225-6HM42-0AA0
3VA2225-6HM42-0AA0
3VA2225-6HM42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,268.22

EACH

Datasheet
3VA2225-6HN32-0AA0
3VA2225-6HN32-0AA0
3VA2225-6HN32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£940.24

EACH

Datasheet
3VA2225-6HN32-0AB0
3VA2225-6HN32-0AB0
3VA2225-6HN32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£956.54

EACH

Datasheet
3VA2225-6HN32-0AC0
3VA2225-6HN32-0AC0
3VA2225-6HN32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£943.18

EACH

Datasheet
3VA2225-6HN32-0AD0
3VA2225-6HN32-0AD0
3VA2225-6HN32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£956.54

EACH

Datasheet
3VA2225-6HN32-0AE0
3VA2225-6HN32-0AE0
3VA2225-6HN32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£969.93

EACH

Datasheet
3VA2225-6HN32-0AF0
3VA2225-6HN32-0AF0
3VA2225-6HN32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£943.18

EACH

Datasheet
3VA2225-6HN32-0AG0
3VA2225-6HN32-0AG0
3VA2225-6HN32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£956.54

EACH

Datasheet
3VA2225-6HN32-0AH0
3VA2225-6HN32-0AH0
3VA2225-6HN32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£956.54

EACH

Datasheet
3VA2225-6HN32-0AJ0
3VA2225-6HN32-0AJ0
3VA2225-6HN32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£983.31

EACH

Datasheet
3VA2225-6HN32-0BA0
3VA2225-6HN32-0BA0
3VA2225-6HN32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£983.31

EACH

Datasheet
3VA2225-6HN32-0BC0
3VA2225-6HN32-0BC0
3VA2225-6HN32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0BH0
3VA2225-6HN32-0BH0
3VA2225-6HN32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,036.83

EACH

Datasheet
3VA2225-6HN32-0BL0
3VA2225-6HN32-0BL0
3VA2225-6HN32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-6HN32-0CA0
3VA2225-6HN32-0CA0
3VA2225-6HN32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£983.31

EACH

Datasheet
3VA2225-6HN32-0CC0
3VA2225-6HN32-0CC0
3VA2225-6HN32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0CH0
3VA2225-6HN32-0CH0
3VA2225-6HN32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,036.83

EACH

Datasheet
3VA2225-6HN32-0CL0
3VA2225-6HN32-0CL0
3VA2225-6HN32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-6HN32-0DA0
3VA2225-6HN32-0DA0
3VA2225-6HN32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£983.31

EACH

Datasheet
3VA2225-6HN32-0DC0
3VA2225-6HN32-0DC0
3VA2225-6HN32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0DH0
3VA2225-6HN32-0DH0
3VA2225-6HN32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,036.83

EACH

Datasheet
3VA2225-6HN32-0DL0
3VA2225-6HN32-0DL0
3VA2225-6HN32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-6HN32-0HA0
3VA2225-6HN32-0HA0
3VA2225-6HN32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£963.24

EACH

Datasheet
3VA2225-6HN32-0HC0
3VA2225-6HN32-0HC0
3VA2225-6HN32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£996.69

EACH

Datasheet
3VA2225-6HN32-0HD0
3VA2225-6HN32-0HD0
3VA2225-6HN32-0HD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip left 24V AC 50/60Hz/24-30V DC 3 auxiliary switches

£1,010.06

EACH

Datasheet
3VA2225-6HN32-0HH0
3VA2225-6HN32-0HH0
3VA2225-6HN32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0HL0
3VA2225-6HN32-0HL0
3VA2225-6HN32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,043.51

EACH

Datasheet
3VA2225-6HN32-0JA0
3VA2225-6HN32-0JA0
3VA2225-6HN32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£963.24

EACH

Datasheet
3VA2225-6HN32-0JC0
3VA2225-6HN32-0JC0
3VA2225-6HN32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£996.69

EACH

Datasheet
3VA2225-6HN32-0JH0
3VA2225-6HN32-0JH0
3VA2225-6HN32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0JL0
3VA2225-6HN32-0JL0
3VA2225-6HN32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,043.51

EACH

Datasheet
3VA2225-6HN32-0KA0
3VA2225-6HN32-0KA0
3VA2225-6HN32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£963.24

EACH

Datasheet
3VA2225-6HN32-0KC0
3VA2225-6HN32-0KC0
3VA2225-6HN32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£996.69

EACH

Datasheet
3VA2225-6HN32-0KH0
3VA2225-6HN32-0KH0
3VA2225-6HN32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,016.75

EACH

Datasheet
3VA2225-6HN32-0KL0
3VA2225-6HN32-0KL0
3VA2225-6HN32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,043.51

EACH

Datasheet
3VA2225-6HN42-0AA0
3VA2225-6HN42-0AA0
3VA2225-6HN42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,125.57

EACH

Datasheet
3VA2225-6HN42-0AD0
3VA2225-6HN42-0AD0
3VA2225-6HN42-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 3 auxiliary switches HQ

£1,224.12

EACH

Datasheet
3VA2225-6HN42-0BA0
3VA2225-6HN42-0BA0
3VA2225-6HN42-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415 V 4pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ...250A short circuit protection Isd=1,5... 10 x Ir, iI=10 x In neutral protection adjustable(off,50%,100%) busbar connection circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415 V 4pole, line protection ETU350, LSI, In=250A overload protection Ir=100A undervoltage release 24 V DC accessory for 3VA1 100/160 3VA2

£1,257.56

EACH

Datasheet
3VA2225-6HN42-0BH0
3VA2225-6HN42-0BH0
3VA2225-6HN42-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,310.54

EACH

Datasheet
3VA2225-6JP32-0AA0
3VA2225-6JP32-0AA0
3VA2225-6JP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,268.39

EACH

Datasheet
3VA2225-6JP32-0AB0
3VA2225-6JP32-0AB0
3VA2225-6JP32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP

£1,264.26

EACH

Datasheet
3VA2225-6JP32-0AC0
3VA2225-6JP32-0AC0
3VA2225-6JP32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ

£1,250.87

EACH

Datasheet
3VA2225-6JP32-0AD0
3VA2225-6JP32-0AD0
3VA2225-6JP32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 3 auxiliary switches HQ

£1,264.26

EACH

Datasheet
3VA2225-6JP32-0AE0
3VA2225-6JP32-0AE0
3VA2225-6JP32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 4 auxiliary switches HQ

£1,277.64

EACH

Datasheet
3VA2225-6JP32-0AF0
3VA2225-6JP32-0AF0
3VA2225-6JP32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,250.87

EACH

Datasheet
3VA2225-6JP32-0AG0
3VA2225-6JP32-0AG0
3VA2225-6JP32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,264.26

EACH

Datasheet
3VA2225-6JP32-0AH0
3VA2225-6JP32-0AH0
3VA2225-6JP32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,264.26

EACH

Datasheet
3VA2225-6JP32-0AJ0
3VA2225-6JP32-0AJ0
3VA2225-6JP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,297.71

EACH

Datasheet
3VA2225-6JP32-0BA0
3VA2225-6JP32-0BA0
3VA2225-6JP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC

£1,297.71

EACH

Datasheet
3VA2225-6JP32-0BC0
3VA2225-6JP32-0BC0
3VA2225-6JP32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0BE0
3VA2225-6JP32-0BE0
3VA2225-6JP32-0BE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC undervoltage release 24V DC 4 auxiliary switches HQ

£1,371.29

EACH

Datasheet
3VA2225-6JP32-0BG0
3VA2225-6JP32-0BG0
3VA2225-6JP32-0BG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 1 auxiliary switch HP 1 trip alarm switch HP

£1,357.91

EACH

Datasheet
3VA2225-6JP32-0BH0
3VA2225-6JP32-0BH0
3VA2225-6JP32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,357.91

EACH

Datasheet
3VA2225-6JP32-0BL0
3VA2225-6JP32-0BL0
3VA2225-6JP32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,384.67

EACH

Datasheet
3VA2225-6JP32-0CA0
3VA2225-6JP32-0CA0
3VA2225-6JP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,297.71

EACH

Datasheet
3VA2225-6JP32-0CC0
3VA2225-6JP32-0CC0
3VA2225-6JP32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0CH0
3VA2225-6JP32-0CH0
3VA2225-6JP32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,357.91

EACH

Datasheet
3VA2225-6JP32-0CL0
3VA2225-6JP32-0CL0
3VA2225-6JP32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,384.67

EACH

Datasheet
3VA2225-6JP32-0DA0
3VA2225-6JP32-0DA0
3VA2225-6JP32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,297.71

EACH

Datasheet
3VA2225-6JP32-0DC0
3VA2225-6JP32-0DC0
3VA2225-6JP32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0DH0
3VA2225-6JP32-0DH0
3VA2225-6JP32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,357.91

EACH

Datasheet
3VA2225-6JP32-0DL0
3VA2225-6JP32-0DL0
3VA2225-6JP32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,384.67

EACH

Datasheet
3VA2225-6JP32-0HA0
3VA2225-6JP32-0HA0
3VA2225-6JP32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,270.94

EACH

Datasheet
3VA2225-6JP32-0HC0
3VA2225-6JP32-0HC0
3VA2225-6JP32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,311.08

EACH

Datasheet
3VA2225-6JP32-0HH0
3VA2225-6JP32-0HH0
3VA2225-6JP32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0HL0
3VA2225-6JP32-0HL0
3VA2225-6JP32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,364.61

EACH

Datasheet
3VA2225-6JP32-0JA0
3VA2225-6JP32-0JA0
3VA2225-6JP32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,270.94

EACH

Datasheet
3VA2225-6JP32-0JC0
3VA2225-6JP32-0JC0
3VA2225-6JP32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,311.08

EACH

Datasheet
3VA2225-6JP32-0JH0
3VA2225-6JP32-0JH0
3VA2225-6JP32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0JL0
3VA2225-6JP32-0JL0
3VA2225-6JP32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,364.61

EACH

Datasheet
3VA2225-6JP32-0KA0
3VA2225-6JP32-0KA0
3VA2225-6JP32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,270.94

EACH

Datasheet
3VA2225-6JP32-0KC0
3VA2225-6JP32-0KC0
3VA2225-6JP32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,311.08

EACH

Datasheet
3VA2225-6JP32-0KH0
3VA2225-6JP32-0KH0
3VA2225-6JP32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2225-6JP32-0KL0
3VA2225-6JP32-0KL0
3VA2225-6JP32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,364.61

EACH

Datasheet
3VA2225-6JP32-0LA0
3VA2225-6JP32-0LA0
3VA2225-6JP32-0LA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit universal release (UNI) 24V DC

£1,371.29

EACH

Datasheet
3VA2225-6JP32-0LK0
3VA2225-6JP32-0LK0
3VA2225-6JP32-0LK0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415 V 3pole, line protection ETU550, LSI, In=250A overload protection Ir=100A ...250A short circuit protection Isd=0,6..10x In, iI=1,5..10x In neutral protection optional with ext. ct,upto 160% busbar connection circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415 V 3pole, line protection ETU550, LSI, In=250A overload protection Ir=100A universal release 24 V DC accessory for 3VA1 100/160 3VA2 1 auxiliary switch changeover H 1 trip alarm switch changeover 1 electrical alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2225-6JP42-0AA0
3VA2225-6JP42-0AA0
3VA2225-6JP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,534.02

EACH

Datasheet
3VA2225-6JP42-0AH0
3VA2225-6JP42-0AH0
3VA2225-6JP42-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,545.20

EACH

Datasheet
3VA2225-6JQ32-0AA0
3VA2225-6JQ32-0AA0
3VA2225-6JQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,464.32

EACH

Datasheet
3VA2225-6JQ32-0AB0
3VA2225-6JQ32-0AB0
3VA2225-6JQ32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP

£1,451.55

EACH

Datasheet
3VA2225-6JQ32-0AC0
3VA2225-6JQ32-0AC0
3VA2225-6JQ32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ

£1,438.18

EACH

Datasheet
3VA2225-6JQ32-0AD0
3VA2225-6JQ32-0AD0
3VA2225-6JQ32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ

£1,451.55

EACH

Datasheet
3VA2225-6JQ32-0AE0
3VA2225-6JQ32-0AE0
3VA2225-6JQ32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 4 auxiliary switches HQ

£1,464.93

EACH

Datasheet
3VA2225-6JQ32-0AF0
3VA2225-6JQ32-0AF0
3VA2225-6JQ32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2225-6JQ32-0AG0
3VA2225-6JQ32-0AG0
3VA2225-6JQ32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,451.55

EACH

Datasheet
3VA2225-6JQ32-0AH0
3VA2225-6JQ32-0AH0
3VA2225-6JQ32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,451.55

EACH

Datasheet
3VA2225-6JQ32-0AJ0
3VA2225-6JQ32-0AJ0
3VA2225-6JQ32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,478.32

EACH

Datasheet
3VA2225-6JQ32-0BA0
3VA2225-6JQ32-0BA0
3VA2225-6JQ32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC

£1,478.32

EACH

Datasheet
3VA2225-6JQ32-0BC0
3VA2225-6JQ32-0BC0
3VA2225-6JQ32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0BH0
3VA2225-6JQ32-0BH0
3VA2225-6JQ32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,531.83

EACH

Datasheet
3VA2225-6JQ32-0BL0
3VA2225-6JQ32-0BL0
3VA2225-6JQ32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,565.27

EACH

Datasheet
3VA2225-6JQ32-0CA0
3VA2225-6JQ32-0CA0
3VA2225-6JQ32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,478.32

EACH

Datasheet
3VA2225-6JQ32-0CC0
3VA2225-6JQ32-0CC0
3VA2225-6JQ32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0CH0
3VA2225-6JQ32-0CH0
3VA2225-6JQ32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,531.83

EACH

Datasheet
3VA2225-6JQ32-0CL0
3VA2225-6JQ32-0CL0
3VA2225-6JQ32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,565.27

EACH

Datasheet
3VA2225-6JQ32-0DA0
3VA2225-6JQ32-0DA0
3VA2225-6JQ32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,478.32

EACH

Datasheet
3VA2225-6JQ32-0DC0
3VA2225-6JQ32-0DC0
3VA2225-6JQ32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0DH0
3VA2225-6JQ32-0DH0
3VA2225-6JQ32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,531.83

EACH

Datasheet
3VA2225-6JQ32-0DL0
3VA2225-6JQ32-0DL0
3VA2225-6JQ32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,565.27

EACH

Datasheet
3VA2225-6JQ32-0HA0
3VA2225-6JQ32-0HA0
3VA2225-6JQ32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,458.25

EACH

Datasheet
3VA2225-6JQ32-0HC0
3VA2225-6JQ32-0HC0
3VA2225-6JQ32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,498.37

EACH

Datasheet
3VA2225-6JQ32-0HH0
3VA2225-6JQ32-0HH0
3VA2225-6JQ32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0HL0
3VA2225-6JQ32-0HL0
3VA2225-6JQ32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,545.20

EACH

Datasheet
3VA2225-6JQ32-0JA0
3VA2225-6JQ32-0JA0
3VA2225-6JQ32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,458.25

EACH

Datasheet
3VA2225-6JQ32-0JC0
3VA2225-6JQ32-0JC0
3VA2225-6JQ32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,498.37

EACH

Datasheet
3VA2225-6JQ32-0JH0
3VA2225-6JQ32-0JH0
3VA2225-6JQ32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0JL0
3VA2225-6JQ32-0JL0
3VA2225-6JQ32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,545.20

EACH

Datasheet
3VA2225-6JQ32-0KA0
3VA2225-6JQ32-0KA0
3VA2225-6JQ32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,458.25

EACH

Datasheet
3VA2225-6JQ32-0KC0
3VA2225-6JQ32-0KC0
3VA2225-6JQ32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,498.37

EACH

Datasheet
3VA2225-6JQ32-0KH0
3VA2225-6JQ32-0KH0
3VA2225-6JQ32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2225-6JQ32-0KL0
3VA2225-6JQ32-0KL0
3VA2225-6JQ32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection, opt. w. external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,545.20

EACH

Datasheet
3VA2225-6JQ42-0AA0
3VA2225-6JQ42-0AA0
3VA2225-6JQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,749.48

EACH

Datasheet
3VA2225-6KP32-0AA0
3VA2225-6KP32-0AA0
3VA2225-6KP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,199.66

EACH

Datasheet
3VA2225-6KP32-0AB0
3VA2225-6KP32-0AB0
3VA2225-6KP32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP

£1,418.11

EACH

Datasheet
3VA2225-6KP32-0AC0
3VA2225-6KP32-0AC0
3VA2225-6KP32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ

£1,404.73

EACH

Datasheet
3VA2225-6KP32-0AD0
3VA2225-6KP32-0AD0
3VA2225-6KP32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 3 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2225-6KP32-0AE0
3VA2225-6KP32-0AE0
3VA2225-6KP32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 4 auxiliary switches HQ

£1,438.18

EACH

Datasheet
3VA2225-6KP32-0AF0
3VA2225-6KP32-0AF0
3VA2225-6KP32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,404.73

EACH

Datasheet
3VA2225-6KP32-0AG0
3VA2225-6KP32-0AG0
3VA2225-6KP32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,418.11

EACH

Datasheet
3VA2225-6KP32-0AH0
3VA2225-6KP32-0AH0
3VA2225-6KP32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2225-6KP32-0AJ0
3VA2225-6KP32-0AJ0
3VA2225-6KP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,451.55

EACH

Datasheet
3VA2225-6KP32-0BA0
3VA2225-6KP32-0BA0
3VA2225-6KP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC

£1,451.55

EACH

Datasheet
3VA2225-6KP32-0BC0
3VA2225-6KP32-0BC0
3VA2225-6KP32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0BH0
3VA2225-6KP32-0BH0
3VA2225-6KP32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2225-6KP32-0BL0
3VA2225-6KP32-0BL0
3VA2225-6KP32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,531.83

EACH

Datasheet
3VA2225-6KP32-0CA0
3VA2225-6KP32-0CA0
3VA2225-6KP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,451.55

EACH

Datasheet
3VA2225-6KP32-0CC0
3VA2225-6KP32-0CC0
3VA2225-6KP32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0CH0
3VA2225-6KP32-0CH0
3VA2225-6KP32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2225-6KP32-0CL0
3VA2225-6KP32-0CL0
3VA2225-6KP32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,531.83

EACH

Datasheet
3VA2225-6KP32-0DA0
3VA2225-6KP32-0DA0
3VA2225-6KP32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,451.55

EACH

Datasheet
3VA2225-6KP32-0DC0
3VA2225-6KP32-0DC0
3VA2225-6KP32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0DH0
3VA2225-6KP32-0DH0
3VA2225-6KP32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2225-6KP32-0DL0
3VA2225-6KP32-0DL0
3VA2225-6KP32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,531.83

EACH

Datasheet
3VA2225-6KP32-0HA0
3VA2225-6KP32-0HA0
3VA2225-6KP32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,424.81

EACH

Datasheet
3VA2225-6KP32-0HC0
3VA2225-6KP32-0HC0
3VA2225-6KP32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,464.93

EACH

Datasheet
3VA2225-6KP32-0HH0
3VA2225-6KP32-0HH0
3VA2225-6KP32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0HL0
3VA2225-6KP32-0HL0
3VA2225-6KP32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,511.75

EACH

Datasheet
3VA2225-6KP32-0JA0
3VA2225-6KP32-0JA0
3VA2225-6KP32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,424.81

EACH

Datasheet
3VA2225-6KP32-0JC0
3VA2225-6KP32-0JC0
3VA2225-6KP32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,464.93

EACH

Datasheet
3VA2225-6KP32-0JH0
3VA2225-6KP32-0JH0
3VA2225-6KP32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0JL0
3VA2225-6KP32-0JL0
3VA2225-6KP32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,511.75

EACH

Datasheet
3VA2225-6KP32-0KA0
3VA2225-6KP32-0KA0
3VA2225-6KP32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,424.81

EACH

Datasheet
3VA2225-6KP32-0KC0
3VA2225-6KP32-0KC0
3VA2225-6KP32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,464.93

EACH

Datasheet
3VA2225-6KP32-0KH0
3VA2225-6KP32-0KH0
3VA2225-6KP32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,491.70

EACH

Datasheet
3VA2225-6KP32-0KL0
3VA2225-6KP32-0KL0
3VA2225-6KP32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,511.75

EACH

Datasheet
3VA2225-6KP42-0AA0
3VA2225-6KP42-0AA0
3VA2225-6KP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,544.56

EACH

Datasheet
3VA2225-6KP42-0HG0
3VA2225-6KP42-0HG0
3VA2225-6KP42-0HG0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 1 auxiliary switch HP 1 trip alarm switch HP

£1,759.26

EACH

Datasheet
3VA2225-6KP42-0KK0
3VA2225-6KP42-0KK0
3VA2225-6KP42-0KK0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,768.08

EACH

Datasheet
3VA2225-6KP42-0LA0
3VA2225-6KP42-0LA0
3VA2225-6KP42-0LA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit universal release (UNI) 24V DC

£1,732.51

EACH

Datasheet
3VA2225-6KQ32-0AA0
3VA2225-6KQ32-0AA0
3VA2225-6KQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,556.79

EACH

Datasheet
3VA2225-6KQ32-0KA0
3VA2225-6KQ32-0KA0
3VA2225-6KQ32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class H SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY

£1,541.00

EACH

Datasheet
3VA2225-6KQ42-0AA0
3VA2225-6KQ42-0AA0
3VA2225-6KQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,826.54

EACH

Datasheet
3VA2225-7HL32-0AA0
3VA2225-7HL32-0AA0
3VA2225-7HL32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit

£962.78

EACH

Datasheet
3VA2225-7HL32-0AB0
3VA2225-7HL32-0AB0
3VA2225-7HL32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£976.62

EACH

Datasheet
3VA2225-7HL32-0AC0
3VA2225-7HL32-0AC0
3VA2225-7HL32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£963.24

EACH

Datasheet
3VA2225-7HL32-0AD0
3VA2225-7HL32-0AD0
3VA2225-7HL32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£976.62

EACH

Datasheet
3VA2225-7HL32-0AE0
3VA2225-7HL32-0AE0
3VA2225-7HL32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£990.00

EACH

Datasheet
3VA2225-7HL32-0AF0
3VA2225-7HL32-0AF0
3VA2225-7HL32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£963.24

EACH

Datasheet
3VA2225-7HL32-0AG0
3VA2225-7HL32-0AG0
3VA2225-7HL32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£976.62

EACH

Datasheet
3VA2225-7HL32-0AH0
3VA2225-7HL32-0AH0
3VA2225-7HL32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£976.62

EACH

Datasheet
3VA2225-7HL32-0AJ0
3VA2225-7HL32-0AJ0
3VA2225-7HL32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,003.39

EACH

Datasheet
3VA2225-7HL32-0BA0
3VA2225-7HL32-0BA0
3VA2225-7HL32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,003.39

EACH

Datasheet
3VA2225-7HL32-0BC0
3VA2225-7HL32-0BC0
3VA2225-7HL32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0BH0
3VA2225-7HL32-0BH0
3VA2225-7HL32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,111.46

EACH

Datasheet
3VA2225-7HL32-0BL0
3VA2225-7HL32-0BL0
3VA2225-7HL32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,083.66

EACH

Datasheet
3VA2225-7HL32-0CA0
3VA2225-7HL32-0CA0
3VA2225-7HL32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,003.39

EACH

Datasheet
3VA2225-7HL32-0CC0
3VA2225-7HL32-0CC0
3VA2225-7HL32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0CH0
3VA2225-7HL32-0CH0
3VA2225-7HL32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,111.46

EACH

Datasheet
3VA2225-7HL32-0CL0
3VA2225-7HL32-0CL0
3VA2225-7HL32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,083.66

EACH

Datasheet
3VA2225-7HL32-0DA0
3VA2225-7HL32-0DA0
3VA2225-7HL32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,003.39

EACH

Datasheet
3VA2225-7HL32-0DC0
3VA2225-7HL32-0DC0
3VA2225-7HL32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0DH0
3VA2225-7HL32-0DH0
3VA2225-7HL32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,111.46

EACH

Datasheet
3VA2225-7HL32-0DL0
3VA2225-7HL32-0DL0
3VA2225-7HL32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,083.66

EACH

Datasheet
3VA2225-7HL32-0HA0
3VA2225-7HL32-0HA0
3VA2225-7HL32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£983.31

EACH

Datasheet
3VA2225-7HL32-0HC0
3VA2225-7HL32-0HC0
3VA2225-7HL32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-7HL32-0HH0
3VA2225-7HL32-0HH0
3VA2225-7HL32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0HL0
3VA2225-7HL32-0HL0
3VA2225-7HL32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-7HL32-0JA0
3VA2225-7HL32-0JA0
3VA2225-7HL32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£983.31

EACH

Datasheet
3VA2225-7HL32-0JC0
3VA2225-7HL32-0JC0
3VA2225-7HL32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-7HL32-0JH0
3VA2225-7HL32-0JH0
3VA2225-7HL32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0JL0
3VA2225-7HL32-0JL0
3VA2225-7HL32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-7HL32-0KA0
3VA2225-7HL32-0KA0
3VA2225-7HL32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£983.31

EACH

Datasheet
3VA2225-7HL32-0KC0
3VA2225-7HL32-0KC0
3VA2225-7HL32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,016.75

EACH

Datasheet
3VA2225-7HL32-0KH0
3VA2225-7HL32-0KH0
3VA2225-7HL32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,043.51

EACH

Datasheet
3VA2225-7HL32-0KL0
3VA2225-7HL32-0KL0
3VA2225-7HL32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,118.49

EACH

Datasheet
3VA2225-7HL42-0AA0
3VA2225-7HL42-0AA0
3VA2225-7HL42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,205.34

EACH

Datasheet
3VA2225-7HM32-0AA0
3VA2225-7HM32-0AA0
3VA2225-7HM32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,136.88

EACH

Datasheet
3VA2225-7HM32-0DH0
3VA2225-7HM32-0DH0
3VA2225-7HM32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,256.56

EACH

Datasheet
3VA2225-7HM32-0HL0
3VA2225-7HM32-0HL0
3VA2225-7HM32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2... 1 x In, tg=0.1/0.3s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,250.87

EACH

Datasheet
3VA2225-7HM42-0AA0
3VA2225-7HM42-0AA0
3VA2225-7HM42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,438.07

EACH

Datasheet
3VA2225-7HN32-0AA0
3VA2225-7HN32-0AA0
3VA2225-7HN32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£1,025.03

EACH

Datasheet
3VA2225-7HN32-0AB0
3VA2225-7HN32-0AB0
3VA2225-7HN32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£1,030.13

EACH

Datasheet
3VA2225-7HN32-0AC0
3VA2225-7HN32-0AC0
3VA2225-7HN32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£1,010.06

EACH

Datasheet
3VA2225-7HN32-0AD0
3VA2225-7HN32-0AD0
3VA2225-7HN32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£1,030.13

EACH

Datasheet
3VA2225-7HN32-0AE0
3VA2225-7HN32-0AE0
3VA2225-7HN32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£1,043.51

EACH

Datasheet
3VA2225-7HN32-0AF0
3VA2225-7HN32-0AF0
3VA2225-7HN32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,010.06

EACH

Datasheet
3VA2225-7HN32-0AG0
3VA2225-7HN32-0AG0
3VA2225-7HN32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,030.13

EACH

Datasheet
3VA2225-7HN32-0AH0
3VA2225-7HN32-0AH0
3VA2225-7HN32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,030.13

EACH

Datasheet
3VA2225-7HN32-0AJ0
3VA2225-7HN32-0AJ0
3VA2225-7HN32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,111.46

EACH

Datasheet
3VA2225-7HN32-0BA0
3VA2225-7HN32-0BA0
3VA2225-7HN32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,111.46

EACH

Datasheet
3VA2225-7HN32-0BC0
3VA2225-7HN32-0BC0
3VA2225-7HN32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0BH0
3VA2225-7HN32-0BH0
3VA2225-7HN32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,110.41

EACH

Datasheet
3VA2225-7HN32-0BL0
3VA2225-7HN32-0BL0
3VA2225-7HN32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-7HN32-0CA0
3VA2225-7HN32-0CA0
3VA2225-7HN32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2225-7HN32-0CC0
3VA2225-7HN32-0CC0
3VA2225-7HN32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0CH0
3VA2225-7HN32-0CH0
3VA2225-7HN32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,110.41

EACH

Datasheet
3VA2225-7HN32-0CL0
3VA2225-7HN32-0CL0
3VA2225-7HN32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-7HN32-0DA0
3VA2225-7HN32-0DA0
3VA2225-7HN32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2225-7HN32-0DC0
3VA2225-7HN32-0DC0
3VA2225-7HN32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0DH0
3VA2225-7HN32-0DH0
3VA2225-7HN32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,110.41

EACH

Datasheet
3VA2225-7HN32-0DL0
3VA2225-7HN32-0DL0
3VA2225-7HN32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2225-7HN32-0HA0
3VA2225-7HN32-0HA0
3VA2225-7HN32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,036.83

EACH

Datasheet
3VA2225-7HN32-0HC0
3VA2225-7HN32-0HC0
3VA2225-7HN32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,125.53

EACH

Datasheet
3VA2225-7HN32-0HH0
3VA2225-7HN32-0HH0
3VA2225-7HN32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0HL0
3VA2225-7HN32-0HL0
3VA2225-7HN32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,117.10

EACH

Datasheet
3VA2225-7HN32-0JA0
3VA2225-7HN32-0JA0
3VA2225-7HN32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,036.83

EACH

Datasheet
3VA2225-7HN32-0JC0
3VA2225-7HN32-0JC0
3VA2225-7HN32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,125.53

EACH

Datasheet
3VA2225-7HN32-0JH0
3VA2225-7HN32-0JH0
3VA2225-7HN32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0JL0
3VA2225-7HN32-0JL0
3VA2225-7HN32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,117.10

EACH

Datasheet
3VA2225-7HN32-0KA0
3VA2225-7HN32-0KA0
3VA2225-7HN32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,036.83

EACH

Datasheet
3VA2225-7HN32-0KC0
3VA2225-7HN32-0KC0
3VA2225-7HN32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,125.53

EACH

Datasheet
3VA2225-7HN32-0KG0
3VA2225-7HN32-0KG0
3VA2225-7HN32-0KG0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 1 auxiliary switch HP 1 trip alarm switch HP

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0KH0
3VA2225-7HN32-0KH0
3VA2225-7HN32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,097.04

EACH

Datasheet
3VA2225-7HN32-0KL0
3VA2225-7HN32-0KL0
3VA2225-7HN32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,117.10

EACH

Datasheet
3VA2225-7HN32-0LE0
3VA2225-7HN32-0LE0
3VA2225-7HN32-0LE0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 4 AUXILIARY SWITCH CHANGEOVER H

£1,259.17

EACH

Datasheet
3VA2225-7HN42-0AA0
3VA2225-7HN42-0AA0
3VA2225-7HN42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,276.32

EACH

Datasheet
3VA2225-7JP32-0AA0
3VA2225-7JP32-0AA0
3VA2225-7JP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,348.71

EACH

Datasheet
3VA2225-7JP32-0AJ0
3VA2225-7JP32-0AJ0
3VA2225-7JP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=250A 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,361.20

EACH

Datasheet
3VA2225-7JP32-0CA0
3VA2225-7JP32-0CA0
3VA2225-7JP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,371.29

EACH

Datasheet
3VA2225-7JP32-0KF0
3VA2225-7JP32-0KF0
3VA2225-7JP32-0KF0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,373.32

EACH

Datasheet
3VA2225-7JP42-0AA0
3VA2225-7JP42-0AA0
3VA2225-7JP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,649.30

EACH

Datasheet
3VA2225-7JQ32-0AA0
3VA2225-7JQ32-0AA0
3VA2225-7JQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,541.39

EACH

Datasheet
3VA2225-7JQ42-0AA0
3VA2225-7JQ42-0AA0
3VA2225-7JQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,849.64

EACH

Datasheet
3VA2225-7JQ42-0DC0
3VA2225-7JQ42-0DC0
3VA2225-7JQ42-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,872.97

EACH

Datasheet
3VA2225-7KP32-0AA0
3VA2225-7KP32-0AA0
3VA2225-7KP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,303.87

EACH

Datasheet
3VA2225-7KP32-0AB0
3VA2225-7KP32-0AB0
3VA2225-7KP32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP

£1,491.70

EACH

Datasheet
3VA2225-7KP32-0AC0
3VA2225-7KP32-0AC0
3VA2225-7KP32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ

£1,471.63

EACH

Datasheet
3VA2225-7KP32-0AD0
3VA2225-7KP32-0AD0
3VA2225-7KP32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 3 auxiliary switches HQ

£1,491.70

EACH

Datasheet
3VA2225-7KP32-0AE0
3VA2225-7KP32-0AE0
3VA2225-7KP32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 4 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2225-7KP32-0AF0
3VA2225-7KP32-0AF0
3VA2225-7KP32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,471.63

EACH

Datasheet
3VA2225-7KP32-0AG0
3VA2225-7KP32-0AG0
3VA2225-7KP32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,491.70

EACH

Datasheet
3VA2225-7KP32-0AH0
3VA2225-7KP32-0AH0
3VA2225-7KP32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,491.70

EACH

Datasheet
3VA2225-7KP32-0AJ0
3VA2225-7KP32-0AJ0
3VA2225-7KP32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,518.45

EACH

Datasheet
3VA2225-7KP32-0BA0
3VA2225-7KP32-0BA0
3VA2225-7KP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC

£1,518.45

EACH

Datasheet
3VA2225-7KP32-0BC0
3VA2225-7KP32-0BC0
3VA2225-7KP32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0BH0
3VA2225-7KP32-0BH0
3VA2225-7KP32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,571.96

EACH

Datasheet
3VA2225-7KP32-0BL0
3VA2225-7KP32-0BL0
3VA2225-7KP32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,598.71

EACH

Datasheet
3VA2225-7KP32-0CA0
3VA2225-7KP32-0CA0
3VA2225-7KP32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,518.45

EACH

Datasheet
3VA2225-7KP32-0CC0
3VA2225-7KP32-0CC0
3VA2225-7KP32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0CH0
3VA2225-7KP32-0CH0
3VA2225-7KP32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,571.96

EACH

Datasheet
3VA2225-7KP32-0CL0
3VA2225-7KP32-0CL0
3VA2225-7KP32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,598.71

EACH

Datasheet
3VA2225-7KP32-0DA0
3VA2225-7KP32-0DA0
3VA2225-7KP32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,518.45

EACH

Datasheet
3VA2225-7KP32-0DC0
3VA2225-7KP32-0DC0
3VA2225-7KP32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0DH0
3VA2225-7KP32-0DH0
3VA2225-7KP32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,571.96

EACH

Datasheet
3VA2225-7KP32-0DL0
3VA2225-7KP32-0DL0
3VA2225-7KP32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,598.71

EACH

Datasheet
3VA2225-7KP32-0HA0
3VA2225-7KP32-0HA0
3VA2225-7KP32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,498.37

EACH

Datasheet
3VA2225-7KP32-0HC0
3VA2225-7KP32-0HC0
3VA2225-7KP32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,531.83

EACH

Datasheet
3VA2225-7KP32-0HH0
3VA2225-7KP32-0HH0
3VA2225-7KP32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0HL0
3VA2225-7KP32-0HL0
3VA2225-7KP32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,578.65

EACH

Datasheet
3VA2225-7KP32-0JA0
3VA2225-7KP32-0JA0
3VA2225-7KP32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,498.37

EACH

Datasheet
3VA2225-7KP32-0JC0
3VA2225-7KP32-0JC0
3VA2225-7KP32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,531.83

EACH

Datasheet
3VA2225-7KP32-0JH0
3VA2225-7KP32-0JH0
3VA2225-7KP32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0JL0
3VA2225-7KP32-0JL0
3VA2225-7KP32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,578.65

EACH

Datasheet
3VA2225-7KP32-0KA0
3VA2225-7KP32-0KA0
3VA2225-7KP32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,498.37

EACH

Datasheet
3VA2225-7KP32-0KC0
3VA2225-7KP32-0KC0
3VA2225-7KP32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,531.83

EACH

Datasheet
3VA2225-7KP32-0KH0
3VA2225-7KP32-0KH0
3VA2225-7KP32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,558.58

EACH

Datasheet
3VA2225-7KP32-0KL0
3VA2225-7KP32-0KL0
3VA2225-7KP32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,578.65

EACH

Datasheet
3VA2225-7KP42-0AA0
3VA2225-7KP42-0AA0
3VA2225-7KP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,811.13

EACH

Datasheet
3VA2225-7KQ32-0AA0
3VA2225-7KQ32-0AA0
3VA2225-7KQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,618.46

EACH

Datasheet
3VA2225-7KQ32-0BA0
3VA2225-7KQ32-0BA0
3VA2225-7KQ32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up

£1,629.08

EACH

Datasheet
3VA2225-7KQ32-0KL0
3VA2225-7KQ32-0KL0
3VA2225-7KQ32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s shunt trip left 208-277V AC 50/60Hz 2 auxiliary switches 1 trip alarm switch 1 electrical alarm switch

£1,685.69

EACH

Datasheet
3VA2225-7KQ42-0AA0
3VA2225-7KQ42-0AA0
3VA2225-7KQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,926.72

EACH

Datasheet
3VA2225-7KQ42-0KK0
3VA2225-7KQ42-0KK0
3VA2225-7KQ42-0KK0circuit breaker 3VA2 IEC frame 250 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, 50%, 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,966.64

EACH

Datasheet
3VA2225-8HL32-0AA0
3VA2225-8HL32-0AA0
3VA2225-8HL32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit

£1,202.09

EACH

Datasheet
3VA2225-8HL32-0AB0
3VA2225-8HL32-0AB0
3VA2225-8HL32-0AB0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£1,110.41

EACH

Datasheet
3VA2225-8HL32-0AC0
3VA2225-8HL32-0AC0
3VA2225-8HL32-0AC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2225-8HL32-0AD0
3VA2225-8HL32-0AD0
3VA2225-8HL32-0AD0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£1,110.41

EACH

Datasheet
3VA2225-8HL32-0AE0
3VA2225-8HL32-0AE0
3VA2225-8HL32-0AE0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£1,123.79

EACH

Datasheet
3VA2225-8HL32-0AF0
3VA2225-8HL32-0AF0
3VA2225-8HL32-0AF0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,097.04

EACH

Datasheet
3VA2225-8HL32-0AG0
3VA2225-8HL32-0AG0
3VA2225-8HL32-0AG0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,110.41

EACH

Datasheet
3VA2225-8HL32-0AH0
3VA2225-8HL32-0AH0
3VA2225-8HL32-0AH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,110.41

EACH

Datasheet
3VA2225-8HL32-0AJ0
3VA2225-8HL32-0AJ0
3VA2225-8HL32-0AJ0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,143.86

EACH

Datasheet
3VA2225-8HL32-0BA0
3VA2225-8HL32-0BA0
3VA2225-8HL32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,143.86

EACH

Datasheet
3VA2225-8HL32-0BC0
3VA2225-8HL32-0BC0
3VA2225-8HL32-0BC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0BH0
3VA2225-8HL32-0BH0
3VA2225-8HL32-0BH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2225-8HL32-0BL0
3VA2225-8HL32-0BL0
3VA2225-8HL32-0BL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,224.12

EACH

Datasheet
3VA2225-8HL32-0CA0
3VA2225-8HL32-0CA0
3VA2225-8HL32-0CA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,143.86

EACH

Datasheet
3VA2225-8HL32-0CC0
3VA2225-8HL32-0CC0
3VA2225-8HL32-0CC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0CH0
3VA2225-8HL32-0CH0
3VA2225-8HL32-0CH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2225-8HL32-0CL0
3VA2225-8HL32-0CL0
3VA2225-8HL32-0CL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,224.12

EACH

Datasheet
3VA2225-8HL32-0DA0
3VA2225-8HL32-0DA0
3VA2225-8HL32-0DA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,143.86

EACH

Datasheet
3VA2225-8HL32-0DC0
3VA2225-8HL32-0DC0
3VA2225-8HL32-0DC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0DH0
3VA2225-8HL32-0DH0
3VA2225-8HL32-0DH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2225-8HL32-0DL0
3VA2225-8HL32-0DL0
3VA2225-8HL32-0DL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,224.12

EACH

Datasheet
3VA2225-8HL32-0HA0
3VA2225-8HL32-0HA0
3VA2225-8HL32-0HA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,117.10

EACH

Datasheet
3VA2225-8HL32-0HC0
3VA2225-8HL32-0HC0
3VA2225-8HL32-0HC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-8HL32-0HH0
3VA2225-8HL32-0HH0
3VA2225-8HL32-0HH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0HL0
3VA2225-8HL32-0HL0
3VA2225-8HL32-0HL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-8HL32-0JA0
3VA2225-8HL32-0JA0
3VA2225-8HL32-0JA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,117.10

EACH

Datasheet
3VA2225-8HL32-0JC0
3VA2225-8HL32-0JC0
3VA2225-8HL32-0JC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-8HL32-0JH0
3VA2225-8HL32-0JH0
3VA2225-8HL32-0JH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0JL0
3VA2225-8HL32-0JL0
3VA2225-8HL32-0JL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-8HL32-0KA0
3VA2225-8HL32-0KA0
3VA2225-8HL32-0KA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,117.10

EACH

Datasheet
3VA2225-8HL32-0KC0
3VA2225-8HL32-0KC0
3VA2225-8HL32-0KC0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,157.23

EACH

Datasheet
3VA2225-8HL32-0KH0
3VA2225-8HL32-0KH0
3VA2225-8HL32-0KH0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,184.00

EACH

Datasheet
3VA2225-8HL32-0KL0
3VA2225-8HL32-0KL0
3VA2225-8HL32-0KL0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,266.21

EACH

Datasheet
3VA2225-8HL42-0AA0
3VA2225-8HL42-0AA0
3VA2225-8HL42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU320, LI, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,419.87

EACH

Datasheet
3VA2225-8HM32-0AA0
3VA2225-8HM32-0AA0
3VA2225-8HM32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,310.18

EACH

Datasheet
3VA2225-8HM42-0AA0
3VA2225-8HM42-0AA0
3VA2225-8HM42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU330, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,664.70

EACH

Datasheet
3VA2225-8HN32-0AA0
3VA2225-8HN32-0AA0
3VA2225-8HN32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£1,156.04

EACH

Datasheet
3VA2225-8HN42-0AA0
3VA2225-8HN42-0AA0
3VA2225-8HN42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,510.55

EACH

Datasheet
3VA2225-8JP32-0AA0
3VA2225-8JP32-0AA0
3VA2225-8JP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,479.73

EACH

Datasheet
3VA2225-8JP42-0AA0
3VA2225-8JP42-0AA0
3VA2225-8JP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU550, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,756.78

EACH

Datasheet
3VA2225-8JQ32-0AA0
3VA2225-8JQ32-0AA0
3VA2225-8JQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,680.11

EACH

Datasheet
3VA2225-8JQ42-0AA0
3VA2225-8JQ42-0AA0
3VA2225-8JQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,034.63

EACH

Datasheet
3VA2225-8KP32-0AA0
3VA2225-8KP32-0AA0
3VA2225-8KP32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,649.30

EACH

Datasheet
3VA2225-8KP32-0BA0
3VA2225-8KP32-0BA0
3VA2225-8KP32-0BA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=250A UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up

£1,658.03

EACH

Datasheet
3VA2225-8KP32-0LA0
3VA2225-8KP32-0LA0
3VA2225-8KP32-0LA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit universal release (UNI) 24V DC

£1,719.13

EACH

Datasheet
3VA2225-8KP42-0AA0
3VA2225-8KP42-0AA0
3VA2225-8KP42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU850, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,887.80

EACH

Datasheet
3VA2225-8KQ32-0AA0
3VA2225-8KQ32-0AA0
3VA2225-8KQ32-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,757.16

EACH

Datasheet
3VA2225-8KQ42-0AA0
3VA2225-8KQ42-0AA0
3VA2225-8KQ42-0AA0circuit breaker 3VA2 IEC frame 250 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU860, LSIG, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,119.41

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM