• Electrika Logo
  • Company
    • About Us
    • Contact Us
  • Products
    • Catalogues
    • Favourites
  • Price Downloads
  • Software
    • Online Estimating
    • Desktop Estimating
    • Desktop Downloads
  • News
  • Blog
  • Sign In
  • |
  • Register

All Companies

Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3VA2140 A
3VA2140-0HL32-0AA0
3VA2140-0HL32-0AA0
3VA2140-0HL32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In busbar connection

£534.47

EACH

Datasheet
3VA2140-0HL36-0AA0
3VA2140-0HL36-0AA0
3VA2140-0HL36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In cable connection

£554.65

EACH

Datasheet
3VA2140-0HL42-0AA0
3VA2140-0HL42-0AA0
3VA2140-0HL42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 100%) busbar connection

£728.23

EACH

Datasheet
3VA2140-0HL46-0AA0
3VA2140-0HL46-0AA0
3VA2140-0HL46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 100%) cable connection

£754.24

EACH

Datasheet
3VA2140-0HM32-0AA0
3VA2140-0HM32-0AA0
3VA2140-0HM32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s busbar connection

£728.23

EACH

Datasheet
3VA2140-0HM36-0AA0
3VA2140-0HM36-0AA0
3VA2140-0HM36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s cable connection

£747.75

EACH

Datasheet
3VA2140-0HM42-0AA0
3VA2140-0HM42-0AA0
3VA2140-0HM42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 100%) ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s busbar connection

£903.80

EACH

Datasheet
3VA2140-0HM46-0AA0
3VA2140-0HM46-0AA0
3VA2140-0HM46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A ... 40A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 100%) ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s cable connection

£984.64

EACH

Datasheet
3VA2140-0HN32-0AA0
3VA2140-0HN32-0AA0
3VA2140-0HN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,5...10xIr, Ii=12xIn busbar connection

£579.34

EACH

Datasheet
3VA2140-0HN36-0AA0
3VA2140-0HN36-0AA0
3VA2140-0HN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,5...10xIr, Ii=12xIn cable connection

£598.85

EACH

Datasheet
3VA2140-0HN42-0AA0
3VA2140-0HN42-0AA0
3VA2140-0HN42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,5...10xIr, Ii=12xIn neutral protection adjustable(OFF 100%) busbar connection

£767.24

EACH

Datasheet
3VA2140-0HN46-0AA0
3VA2140-0HN46-0AA0
3VA2140-0HN46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,5...10xIr, Ii=12xIn neutral protection adjustable(OFF 100%) cable connection

£834.20

EACH

Datasheet
3VA2140-0KP32-0AA0
3VA2140-0KP32-0AA0
3VA2140-0KP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn busbar connection

£1,053.33

EACH

Datasheet
3VA2140-0KP36-0AA0
3VA2140-0KP36-0AA0
3VA2140-0KP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn cable connection

£1,121.40

EACH

Datasheet
3VA2140-0KP42-0AA0
3VA2140-0KP42-0AA0
3VA2140-0KP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) busbar connection

£1,228.89

EACH

Datasheet
3VA2140-0KP46-0AA0
3VA2140-0KP46-0AA0
3VA2140-0KP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) cable connection

£1,254.89

EACH

Datasheet
3VA2140-0KQ32-0AA0
3VA2140-0KQ32-0AA0
3VA2140-0KQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn busbar connection

£1,157.37

EACH

Datasheet
3VA2140-0KQ36-0AA0
3VA2140-0KQ36-0AA0
3VA2140-0KQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn cable connection

£1,170.38

EACH

Datasheet
3VA2140-0KQ42-0AA0
3VA2140-0KQ42-0AA0
3VA2140-0KQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) busbar connection

£1,345.92

EACH

Datasheet
3VA2140-0KQ46-0AA0
3VA2140-0KQ46-0AA0
3VA2140-0KQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) cable connection

£1,365.45

EACH

Datasheet
3VA2140-0MN32-0AA0
3VA2140-0MN32-0AA0
3VA2140-0MN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=3...15xIr, Ii=15xIn busbar connection

£498.06

EACH

Datasheet
3VA2140-0MN36-0AA0
3VA2140-0MN36-0AA0
3VA2140-0MN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=3...15xIr, Ii=15xIn cable connection

£517.58

EACH

Datasheet
3VA2140-0MQ32-0AA0
3VA2140-0MQ32-0AA0
3VA2140-0MQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,2...15xIn, Ii=3...15xIn busbar connection

£884.28

EACH

Datasheet
3VA2140-0MQ36-0AA0
3VA2140-0MQ36-0AA0
3VA2140-0MQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=40A overload protection Ir=16A ... 40A short circuit protection Isd=1,2...15xIn, Ii=3...15xIn cable connection

£964.12

EACH

Datasheet
3VA2140-0MS32-0AA0
3VA2140-0MS32-0AA0
3VA2140-0MS32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=40A short circuit protection Ii=3...15 x In busbar connection

£369.97

EACH

Datasheet
3VA2140-0MS36-0AA0
3VA2140-0MS36-0AA0
3VA2140-0MS36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=40A short circuit protection Ii=3...15 x In cable connection

£389.47

EACH

Datasheet
3VA2140-5HK32-0AA0
3VA2140-5HK32-0AA0
3VA2140-5HK32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In nut keeper kit

£373.80

EACH

Datasheet
3VA2140-5HK36-0AA0
3VA2140-5HK36-0AA0
3VA2140-5HK36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In clamp connection

£387.90

EACH

Datasheet
3VA2140-5HK42-0AA0
3VA2140-5HK42-0AA0
3VA2140-5HK42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£472.46

EACH

Datasheet
3VA2140-5HK46-0AA0
3VA2140-5HK46-0AA0
3VA2140-5HK46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) clamp connection

£491.21

EACH

Datasheet
3VA2140-5HL32-0AA0
3VA2140-5HL32-0AA0
3VA2140-5HL32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut keeper kit

£355.53

EACH

Datasheet
3VA2140-5HL32-0AB0
3VA2140-5HL32-0AB0
3VA2140-5HL32-0AB0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut keeper kit circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut 2 AUXILIARY SWITCH CHANGEOVER H

£409.63

EACH

Datasheet
3VA2140-5HL36-0AA0
3VA2140-5HL36-0AA0
3VA2140-5HL36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In clamp connection

£369.62

EACH

Datasheet
3VA2140-5HL42-0AA0
3VA2140-5HL42-0AA0
3VA2140-5HL42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£472.46

EACH

Datasheet
3VA2140-5HL46-0AA0
3VA2140-5HL46-0AA0
3VA2140-5HL46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£491.21

EACH

Datasheet
3VA2140-5HM32-0AA0
3VA2140-5HM32-0AA0
3VA2140-5HM32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s nut keeper kit

£570.32

EACH

Datasheet
3VA2140-5HM36-0AA0
3VA2140-5HM36-0AA0
3VA2140-5HM36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s clamp connection

£584.38

EACH

Datasheet
3VA2140-5HM42-0AA0
3VA2140-5HM42-0AA0
3VA2140-5HM42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s nut keeper kit

£702.71

EACH

Datasheet
3VA2140-5HM46-0AA0
3VA2140-5HM46-0AA0
3VA2140-5HM46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s clamp connection

£722.43

EACH

Datasheet
3VA2140-5HN32-0AA0
3VA2140-5HN32-0AA0
3VA2140-5HN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In nut keeper kit

£651.75

EACH

Datasheet
3VA2140-5HN36-0AA0
3VA2140-5HN36-0AA0
3VA2140-5HN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection

£665.83

EACH

Datasheet
3VA2140-5HN42-0AA0
3VA2140-5HN42-0AA0
3VA2140-5HN42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£629.22

EACH

Datasheet
3VA2140-5HN46-0AA0
3VA2140-5HN46-0AA0
3VA2140-5HN46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£647.98

EACH

Datasheet
3VA2140-5JP32-0AA0
3VA2140-5JP32-0AA0
3VA2140-5JP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£748.36

EACH

Datasheet
3VA2140-5JP36-0AA0
3VA2140-5JP36-0AA0
3VA2140-5JP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£762.44

EACH

Datasheet
3VA2140-5JP42-0AA0
3VA2140-5JP42-0AA0
3VA2140-5JP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£847.77

EACH

Datasheet
3VA2140-5JP46-0AA0
3VA2140-5JP46-0AA0
3VA2140-5JP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£866.54

EACH

Datasheet
3VA2140-5JQ32-0AA0
3VA2140-5JQ32-0AA0
3VA2140-5JQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£900.18

EACH

Datasheet
3VA2140-5JQ36-0AA0
3VA2140-5JQ36-0AA0
3VA2140-5JQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£961.46

EACH

Datasheet
3VA2140-5JQ42-0AA0
3VA2140-5JQ42-0AA0
3VA2140-5JQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,048.15

EACH

Datasheet
3VA2140-5JQ46-0AA0
3VA2140-5JQ46-0AA0
3VA2140-5JQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,066.91

EACH

Datasheet
3VA2140-5KP32-0AA0
3VA2140-5KP32-0AA0
3VA2140-5KP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£833.29

EACH

Datasheet
3VA2140-5KP36-0AA0
3VA2140-5KP36-0AA0
3VA2140-5KP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£847.36

EACH

Datasheet
3VA2140-5KP42-0AA0
3VA2140-5KP42-0AA0
3VA2140-5KP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£1,055.86

EACH

Datasheet
3VA2140-5KP46-0AA0
3VA2140-5KP46-0AA0
3VA2140-5KP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,074.61

EACH

Datasheet
3VA2140-5KQ32-0AA0
3VA2140-5KQ32-0AA0
3VA2140-5KQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£954.63

EACH

Datasheet
3VA2140-5KQ36-0AA0
3VA2140-5KQ36-0AA0
3VA2140-5KQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£968.70

EACH

Datasheet
3VA2140-5KQ42-0AA0
3VA2140-5KQ42-0AA0
3VA2140-5KQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,215.71

EACH

Datasheet
3VA2140-5KQ46-0AA0
3VA2140-5KQ46-0AA0
3VA2140-5KQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,174.81

EACH

Datasheet
3VA2140-5MN32-0AA0
3VA2140-5MN32-0AA0
3VA2140-5MN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit

£339.27

EACH

Datasheet
3VA2140-5MN32-0AB0
3VA2140-5MN32-0AB0
3VA2140-5MN32-0AB0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP

£444.16

EACH

Datasheet
3VA2140-5MN32-0AC0
3VA2140-5MN32-0AC0
3VA2140-5MN32-0AC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ

£427.45

EACH

Datasheet
3VA2140-5MN32-0AD0
3VA2140-5MN32-0AD0
3VA2140-5MN32-0AD0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 3 auxiliary switches HQ

£444.16

EACH

Datasheet
3VA2140-5MN32-0AE0
3VA2140-5MN32-0AE0
3VA2140-5MN32-0AE0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 4 auxiliary switches HQ

£462.21

EACH

Datasheet
3VA2140-5MN32-0AF0
3VA2140-5MN32-0AF0
3VA2140-5MN32-0AF0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£427.45

EACH

Datasheet
3VA2140-5MN32-0AG0
3VA2140-5MN32-0AG0
3VA2140-5MN32-0AG0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£444.16

EACH

Datasheet
3VA2140-5MN32-0AH0
3VA2140-5MN32-0AH0
3VA2140-5MN32-0AH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£444.16

EACH

Datasheet
3VA2140-5MN32-0AJ0
3VA2140-5MN32-0AJ0
3VA2140-5MN32-0AJ0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£471.59

EACH

Datasheet
3VA2140-5MN32-0BA0
3VA2140-5MN32-0BA0
3VA2140-5MN32-0BA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£473.60

EACH

Datasheet
3VA2140-5MN32-0BC0
3VA2140-5MN32-0BC0
3VA2140-5MN32-0BC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£509.71

EACH

Datasheet
3VA2140-5MN32-0BH0
3VA2140-5MN32-0BH0
3VA2140-5MN32-0BH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£527.78

EACH

Datasheet
3VA2140-5MN32-0BL0
3VA2140-5MN32-0BL0
3VA2140-5MN32-0BL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£554.53

EACH

Datasheet
3VA2140-5MN32-0CA0
3VA2140-5MN32-0CA0
3VA2140-5MN32-0CA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£473.60

EACH

Datasheet
3VA2140-5MN32-0CC0
3VA2140-5MN32-0CC0
3VA2140-5MN32-0CC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£509.71

EACH

Datasheet
3VA2140-5MN32-0CH0
3VA2140-5MN32-0CH0
3VA2140-5MN32-0CH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£527.78

EACH

Datasheet
3VA2140-5MN32-0CL0
3VA2140-5MN32-0CL0
3VA2140-5MN32-0CL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£554.53

EACH

Datasheet
3VA2140-5MN32-0DA0
3VA2140-5MN32-0DA0
3VA2140-5MN32-0DA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£473.60

EACH

Datasheet
3VA2140-5MN32-0DC0
3VA2140-5MN32-0DC0
3VA2140-5MN32-0DC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£509.71

EACH

Datasheet
3VA2140-5MN32-0DH0
3VA2140-5MN32-0DH0
3VA2140-5MN32-0DH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£527.78

EACH

Datasheet
3VA2140-5MN32-0DL0
3VA2140-5MN32-0DL0
3VA2140-5MN32-0DL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£554.53

EACH

Datasheet
3VA2140-5MN32-0HA0
3VA2140-5MN32-0HA0
3VA2140-5MN32-0HA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£454.21

EACH

Datasheet
3VA2140-5MN32-0HC0
3VA2140-5MN32-0HC0
3VA2140-5MN32-0HC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£490.99

EACH

Datasheet
3VA2140-5MN32-0HH0
3VA2140-5MN32-0HH0
3VA2140-5MN32-0HH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£508.39

EACH

Datasheet
3VA2140-5MN32-0HL0
3VA2140-5MN32-0HL0
3VA2140-5MN32-0HL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£535.14

EACH

Datasheet
3VA2140-5MN32-0JA0
3VA2140-5MN32-0JA0
3VA2140-5MN32-0JA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£454.21

EACH

Datasheet
3VA2140-5MN32-0JC0
3VA2140-5MN32-0JC0
3VA2140-5MN32-0JC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£490.99

EACH

Datasheet
3VA2140-5MN32-0JH0
3VA2140-5MN32-0JH0
3VA2140-5MN32-0JH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£508.39

EACH

Datasheet
3VA2140-5MN32-0JL0
3VA2140-5MN32-0JL0
3VA2140-5MN32-0JL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£535.14

EACH

Datasheet
3VA2140-5MN32-0KA0
3VA2140-5MN32-0KA0
3VA2140-5MN32-0KA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£454.21

EACH

Datasheet
3VA2140-5MN32-0KC0
3VA2140-5MN32-0KC0
3VA2140-5MN32-0KC0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£490.99

EACH

Datasheet
3VA2140-5MN32-0KH0
3VA2140-5MN32-0KH0
3VA2140-5MN32-0KH0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£508.39

EACH

Datasheet
3VA2140-5MN32-0KL0
3VA2140-5MN32-0KL0
3VA2140-5MN32-0KL0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£535.14

EACH

Datasheet
3VA2140-5MN36-0AA0
3VA2140-5MN36-0AA0
3VA2140-5MN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In clamp connection

£355.52

EACH

Datasheet
3VA2140-5MN36-0AB0
3VA2140-5MN36-0AB0
3VA2140-5MN36-0AB0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In clamp connection circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 2 auxiliary switches HP

£462.21

EACH

Datasheet
3VA2140-5MP32-0AA0
3VA2140-5MP32-0AA0
3VA2140-5MP32-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=40A OVERLOAD PROTECTION IR=16A ...40A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION

£533.79

EACH

Datasheet
3VA2140-5MP36-0AA0
3VA2140-5MP36-0AA0
3VA2140-5MP36-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=40A OVERLOAD PROTECTION IR=16A ...40A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN CABLE CONNECTION

£552.53

EACH

Datasheet
3VA2140-5MQ32-0AA0
3VA2140-5MQ32-0AA0
3VA2140-5MQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£786.11

EACH

Datasheet
3VA2140-5MQ36-0AA0
3VA2140-5MQ36-0AA0
3VA2140-5MQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£800.17

EACH

Datasheet
3VA2140-6HK32-0AA0
3VA2140-6HK32-0AA0
3VA2140-6HK32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In nut keeper kit

£416.17

EACH

Datasheet
3VA2140-6HK36-0AA0
3VA2140-6HK36-0AA0
3VA2140-6HK36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In clamp connection

£430.24

EACH

Datasheet
3VA2140-6HK42-0AA0
3VA2140-6HK42-0AA0
3VA2140-6HK42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£529.48

EACH

Datasheet
3VA2140-6HK46-0AA0
3VA2140-6HK46-0AA0
3VA2140-6HK46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) clamp connection

£548.27

EACH

Datasheet
3VA2140-6HL32-0AA0
3VA2140-6HL32-0AA0
3VA2140-6HL32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut keeper kit

£388.83

EACH

Datasheet
3VA2140-6HL36-0AA0
3VA2140-6HL36-0AA0
3VA2140-6HL36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In clamp connection

£402.90

EACH

Datasheet
3VA2140-6HL42-0AA0
3VA2140-6HL42-0AA0
3VA2140-6HL42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£528.70

EACH

Datasheet
3VA2140-6HL46-0AA0
3VA2140-6HL46-0AA0
3VA2140-6HL46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£547.47

EACH

Datasheet
3VA2140-6HM32-0AA0
3VA2140-6HM32-0AA0
3VA2140-6HM32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s nut keeper kit

£611.94

EACH

Datasheet
3VA2140-6HM36-0AA0
3VA2140-6HM36-0AA0
3VA2140-6HM36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s clamp connection

£626.01

EACH

Datasheet
3VA2140-6HM42-0AA0
3VA2140-6HM42-0AA0
3VA2140-6HM42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s nut keeper kit

£726.00

EACH

Datasheet
3VA2140-6HM46-0AA0
3VA2140-6HM46-0AA0
3VA2140-6HM46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s clamp connection

£744.76

EACH

Datasheet
3VA2140-6HN32-0AA0
3VA2140-6HN32-0AA0
3VA2140-6HN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In nut keeper kit

£674.03

EACH

Datasheet
3VA2140-6HN36-0AA0
3VA2140-6HN36-0AA0
3VA2140-6HN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection

£688.11

EACH

Datasheet
3VA2140-6HN42-0AA0
3VA2140-6HN42-0AA0
3VA2140-6HN42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£704.72

EACH

Datasheet
3VA2140-6HN46-0AA0
3VA2140-6HN46-0AA0
3VA2140-6HN46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£723.47

EACH

Datasheet
3VA2140-6JP32-0AA0
3VA2140-6JP32-0AA0
3VA2140-6JP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£786.11

EACH

Datasheet
3VA2140-6JP36-0AA0
3VA2140-6JP36-0AA0
3VA2140-6JP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£800.17

EACH

Datasheet
3VA2140-6JP42-0AA0
3VA2140-6JP42-0AA0
3VA2140-6JP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£901.72

EACH

Datasheet
3VA2140-6JP46-0AA0
3VA2140-6JP46-0AA0
3VA2140-6JP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£920.47

EACH

Datasheet
3VA2140-6JQ32-0AA0
3VA2140-6JQ32-0AA0
3VA2140-6JQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£954.63

EACH

Datasheet
3VA2140-6JQ32-0DH0
3VA2140-6JQ32-0DH0
3VA2140-6JQ32-0DH0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,083.66

EACH

Datasheet
3VA2140-6JQ36-0AA0
3VA2140-6JQ36-0AA0
3VA2140-6JQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£968.70

EACH

Datasheet
3VA2140-6JQ42-0AA0
3VA2140-6JQ42-0AA0
3VA2140-6JQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,102.09

EACH

Datasheet
3VA2140-6JQ46-0AA0
3VA2140-6JQ46-0AA0
3VA2140-6JQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,178.72

EACH

Datasheet
3VA2140-6KP32-0AA0
3VA2140-6KP32-0AA0
3VA2140-6KP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£905.01

EACH

Datasheet
3VA2140-6KP36-0AA0
3VA2140-6KP36-0AA0
3VA2140-6KP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£966.55

EACH

Datasheet
3VA2140-6KP42-0AA0
3VA2140-6KP42-0AA0
3VA2140-6KP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£1,109.80

EACH

Datasheet
3VA2140-6KP42-0DK0
3VA2140-6KP42-0DK0
3VA2140-6KP42-0DK0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,170.61

EACH

Datasheet
3VA2140-6KP46-0AA0
3VA2140-6KP46-0AA0
3VA2140-6KP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,128.57

EACH

Datasheet
3VA2140-6KQ32-0AA0
3VA2140-6KQ32-0AA0
3VA2140-6KQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£1,026.37

EACH

Datasheet
3VA2140-6KQ32-0KF0
3VA2140-6KQ32-0KF0
3VA2140-6KQ32-0KF0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,123.79

EACH

Datasheet
3VA2140-6KQ36-0AA0
3VA2140-6KQ36-0AA0
3VA2140-6KQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£1,040.42

EACH

Datasheet
3VA2140-6KQ42-0AA0
3VA2140-6KQ42-0AA0
3VA2140-6KQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,217.69

EACH

Datasheet
3VA2140-6KQ46-0AA0
3VA2140-6KQ46-0AA0
3VA2140-6KQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,236.47

EACH

Datasheet
3VA2140-7HK32-0AA0
3VA2140-7HK32-0AA0
3VA2140-7HK32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In nut keeper kit

£443.92

EACH

Datasheet
3VA2140-7HK36-0AA0
3VA2140-7HK36-0AA0
3VA2140-7HK36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In clamp connection

£457.98

EACH

Datasheet
3VA2140-7HK42-0AA0
3VA2140-7HK42-0AA0
3VA2140-7HK42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£567.24

EACH

Datasheet
3VA2140-7HK46-0AA0
3VA2140-7HK46-0AA0
3VA2140-7HK46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) clamp connection

£585.99

EACH

Datasheet
3VA2140-7HL32-0AA0
3VA2140-7HL32-0AA0
3VA2140-7HL32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut keeper kit

£443.92

EACH

Datasheet
3VA2140-7HL36-0AA0
3VA2140-7HL36-0AA0
3VA2140-7HL36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In clamp connection

£457.98

EACH

Datasheet
3VA2140-7HL42-0AA0
3VA2140-7HL42-0AA0
3VA2140-7HL42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£567.24

EACH

Datasheet
3VA2140-7HL46-0AA0
3VA2140-7HL46-0AA0
3VA2140-7HL46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£585.99

EACH

Datasheet
3VA2140-7HM32-0AA0
3VA2140-7HM32-0AA0
3VA2140-7HM32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s nut keeper kit

£673.52

EACH

Datasheet
3VA2140-7HM36-0AA0
3VA2140-7HM36-0AA0
3VA2140-7HM36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s clamp connection

£688.33

EACH

Datasheet
3VA2140-7HM42-0AA0
3VA2140-7HM42-0AA0
3VA2140-7HM42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s nut keeper kit

£762.98

EACH

Datasheet
3VA2140-7HM46-0AA0
3VA2140-7HM46-0AA0
3VA2140-7HM46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s clamp connection

£781.75

EACH

Datasheet
3VA2140-7HN32-0AA0
3VA2140-7HN32-0AA0
3VA2140-7HN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In nut keeper kit

£711.26

EACH

Datasheet
3VA2140-7HN36-0AA0
3VA2140-7HN36-0AA0
3VA2140-7HN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection

£725.36

EACH

Datasheet
3VA2140-7HN42-0AA0
3VA2140-7HN42-0AA0
3VA2140-7HN42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£773.90

EACH

Datasheet
3VA2140-7HN46-0AA0
3VA2140-7HN46-0AA0
3VA2140-7HN46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£833.59

EACH

Datasheet
3VA2140-7JP32-0AA0
3VA2140-7JP32-0AA0
3VA2140-7JP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£859.11

EACH

Datasheet
3VA2140-7JP36-0AA0
3VA2140-7JP36-0AA0
3VA2140-7JP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£873.93

EACH

Datasheet
3VA2140-7JP42-0AA0
3VA2140-7JP42-0AA0
3VA2140-7JP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£932.54

EACH

Datasheet
3VA2140-7JP46-0AA0
3VA2140-7JP46-0AA0
3VA2140-7JP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,000.41

EACH

Datasheet
3VA2140-7JQ32-0AA0
3VA2140-7JQ32-0AA0
3VA2140-7JQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£998.86

EACH

Datasheet
3VA2140-7JQ36-0AA0
3VA2140-7JQ36-0AA0
3VA2140-7JQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£1,012.94

EACH

Datasheet
3VA2140-7JQ42-0AA0
3VA2140-7JQ42-0AA0
3VA2140-7JQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,132.93

EACH

Datasheet
3VA2140-7JQ46-0AA0
3VA2140-7JQ46-0AA0
3VA2140-7JQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,151.68

EACH

Datasheet
3VA2140-7KP32-0AA0
3VA2140-7KP32-0AA0
3VA2140-7KP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,027.17

EACH

Datasheet
3VA2140-7KP36-0AA0
3VA2140-7KP36-0AA0
3VA2140-7KP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£990.82

EACH

Datasheet
3VA2140-7KP42-0AA0
3VA2140-7KP42-0AA0
3VA2140-7KP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£1,148.33

EACH

Datasheet
3VA2140-7KP46-0AA0
3VA2140-7KP46-0AA0
3VA2140-7KP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,227.36

EACH

Datasheet
3VA2140-7KQ32-0AA0
3VA2140-7KQ32-0AA0
3VA2140-7KQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£1,097.41

EACH

Datasheet
3VA2140-7KQ36-0AA0
3VA2140-7KQ36-0AA0
3VA2140-7KQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£1,168.87

EACH

Datasheet
3VA2140-7KQ42-0AA0
3VA2140-7KQ42-0AA0
3VA2140-7KQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,263.93

EACH

Datasheet
3VA2140-7KQ46-0AA0
3VA2140-7KQ46-0AA0
3VA2140-7KQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,282.70

EACH

Datasheet
3VA2140-7MN32-0AA0
3VA2140-7MN32-0AA0
3VA2140-7MN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit

£395.83

EACH

Datasheet
3VA2140-7MN32-0BH0
3VA2140-7MN32-0BH0
3VA2140-7MN32-0BH0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release 24V DC 2 auxiliary switches 1 trip alarm switch

£593.34

EACH

Datasheet
3VA2140-7MN36-0AA0
3VA2140-7MN36-0AA0
3VA2140-7MN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In clamp connection

£410.88

EACH

Datasheet
3VA2140-7MN36-0BH0
3VA2140-7MN36-0BH0
3VA2140-7MN36-0BH0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=3...15 x Ir, Ii=15 x In clamp connection undervoltage release 24V DC 2 auxiliary switches 1 trip alarm switch

£642.25

EACH

Datasheet
3VA2140-7MP32-0AA0
3VA2140-7MP32-0AA0
3VA2140-7MP32-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=40A OVERLOAD PROTECTION IR=16A ...40A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION

£598.68

EACH

Datasheet
3VA2140-7MP36-0AA0
3VA2140-7MP36-0AA0
3VA2140-7MP36-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=40A OVERLOAD PROTECTION IR=16A ...40A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN CABLE CONNECTION

£647.87

EACH

Datasheet
3VA2140-7MQ32-0AA0
3VA2140-7MQ32-0AA0
3VA2140-7MQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£847.77

EACH

Datasheet
3VA2140-7MQ32-0DH0
3VA2140-7MQ32-0DH0
3VA2140-7MQ32-0DH0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£949.87

EACH

Datasheet
3VA2140-7MQ36-0AA0
3VA2140-7MQ36-0AA0
3VA2140-7MQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£861.84

EACH

Datasheet
3VA2140-7MQ36-0AD0
3VA2140-7MQ36-0AD0
3VA2140-7MQ36-0AD0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection circuit breaker 3VA2 IEC frame 160 3 auxiliary switches HQ

£882.98

EACH

Datasheet
3VA2140-7MQ36-0JA0
3VA2140-7MQ36-0JA0
3VA2140-7MQ36-0JA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, SHUNT TRIP LEFT 110-127 V AC 50/60 HZ / DC ACCESSORY FOR

£892.69

EACH

Datasheet
3VA2140-7MS32-0AA0
3VA2140-7MS32-0AA0
3VA2140-7MS32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=40A without overload protection short-circuit protection Ii=3...15 x In nut keeper kit

£337.57

EACH

Datasheet
3VA2140-7MS36-0AA0
3VA2140-7MS36-0AA0
3VA2140-7MS36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=40A without overload protection short-circuit protection Ii=3...15 x In clamp connection

£351.66

EACH

Datasheet
3VA2140-8HK32-0AA0
3VA2140-8HK32-0AA0
3VA2140-8HK32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In nut keeper kit

£500.20

EACH

Datasheet
3VA2140-8HK36-0AA0
3VA2140-8HK36-0AA0
3VA2140-8HK36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In clamp connection

£514.25

EACH

Datasheet
3VA2140-8HK42-0AA0
3VA2140-8HK42-0AA0
3VA2140-8HK42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£642.76

EACH

Datasheet
3VA2140-8HK46-0AA0
3VA2140-8HK46-0AA0
3VA2140-8HK46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=15 x In N conductor protection adjustable (OFF, 100%) clamp connection

£695.68

EACH

Datasheet
3VA2140-8HL32-0AA0
3VA2140-8HL32-0AA0
3VA2140-8HL32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In nut keeper kit

£608.71

EACH

Datasheet
3VA2140-8HL36-0AA0
3VA2140-8HL36-0AA0
3VA2140-8HL36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In clamp connection

£622.78

EACH

Datasheet
3VA2140-8HL42-0AA0
3VA2140-8HL42-0AA0
3VA2140-8HL42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£788.36

EACH

Datasheet
3VA2140-8HL46-0AA0
3VA2140-8HL46-0AA0
3VA2140-8HL46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU320, LI, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£848.81

EACH

Datasheet
3VA2140-8HM32-0AA0
3VA2140-8HM32-0AA0
3VA2140-8HM32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s nut keeper kit

£731.89

EACH

Datasheet
3VA2140-8HM36-0AA0
3VA2140-8HM36-0AA0
3VA2140-8HM36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.4... 1 x In, tg=0.1/0.3s clamp connection

£710.02

EACH

Datasheet
3VA2140-8HM42-0AA0
3VA2140-8HM42-0AA0
3VA2140-8HM42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s nut keeper kit

£883.43

EACH

Datasheet
3VA2140-8HM46-0AA0
3VA2140-8HM46-0AA0
3VA2140-8HM46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU330, LIG, In=40A overload protection Ir=16A...40A short-circuit protection Ii=1.5...12 x In N conductor protection adjustable (OFF, 100%) ground-fault protection Ig=0.4...1 x In= tg=0.1/0.3s clamp connection

£858.82

EACH

Datasheet
3VA2140-8HN32-0AA0
3VA2140-8HN32-0AA0
3VA2140-8HN32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In nut keeper kit

£945.90

EACH

Datasheet
3VA2140-8HN36-0AA0
3VA2140-8HN36-0AA0
3VA2140-8HN36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection

£959.98

EACH

Datasheet
3VA2140-8HN42-0AA0
3VA2140-8HN42-0AA0
3VA2140-8HN42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) nut keeper kit

£1,058.70

EACH

Datasheet
3VA2140-8HN46-0AA0
3VA2140-8HN46-0AA0
3VA2140-8HN46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU350, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In N conductor protection adjustable (OFF, 100%) clamp connection

£1,025.50

EACH

Datasheet
3VA2140-8JP32-0AA0
3VA2140-8JP32-0AA0
3VA2140-8JP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£870.87

EACH

Datasheet
3VA2140-8JP36-0AA0
3VA2140-8JP36-0AA0
3VA2140-8JP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£884.96

EACH

Datasheet
3VA2140-8JP42-0AA0
3VA2140-8JP42-0AA0
3VA2140-8JP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£1,025.03

EACH

Datasheet
3VA2140-8JP46-0AA0
3VA2140-8JP46-0AA0
3VA2140-8JP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,043.80

EACH

Datasheet
3VA2140-8JQ32-0AA0
3VA2140-8JQ32-0AA0
3VA2140-8JQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£1,071.27

EACH

Datasheet
3VA2140-8JQ36-0AA0
3VA2140-8JQ36-0AA0
3VA2140-8JQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£1,085.34

EACH

Datasheet
3VA2140-8JQ42-0AA0
3VA2140-8JQ42-0AA0
3VA2140-8JQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,281.76

EACH

Datasheet
3VA2140-8JQ46-0AA0
3VA2140-8JQ46-0AA0
3VA2140-8JQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,300.55

EACH

Datasheet
3VA2140-8KP32-0AA0
3VA2140-8KP32-0AA0
3VA2140-8KP32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£976.41

EACH

Datasheet
3VA2140-8KP36-0AA0
3VA2140-8KP36-0AA0
3VA2140-8KP36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% clamp connection

£990.50

EACH

Datasheet
3VA2140-8KP42-0AA0
3VA2140-8KP42-0AA0
3VA2140-8KP42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) nut keeper kit

£1,240.84

EACH

Datasheet
3VA2140-8KP46-0AA0
3VA2140-8KP46-0AA0
3VA2140-8KP46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU850, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection

£1,259.59

EACH

Datasheet
3VA2140-8KQ32-0AA0
3VA2140-8KQ32-0AA0
3VA2140-8KQ32-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s nut keeper kit

£1,097.41

EACH

Datasheet
3VA2140-8KQ36-0AA0
3VA2140-8KQ36-0AA0
3VA2140-8KQ36-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.4... 1 x In, tg=0.05-0.8s clamp connection

£1,111.49

EACH

Datasheet
3VA2140-8KQ42-0AA0
3VA2140-8KQ42-0AA0
3VA2140-8KQ42-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s nut keeper kit

£1,348.71

EACH

Datasheet
3VA2140-8KQ46-0AA0
3VA2140-8KQ46-0AA0
3VA2140-8KQ46-0AA0circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU860, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.4...1 x In= tg=0.05-0.8s clamp connection

£1,367.50

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM