https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3VA23400 A
3VA2340-0HL32-0AA0
3VA2340-0HL32-0AA0
3VA2340-0HL32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A ... 400A short circuit protection Ii=1,5...12 x In busbar connection

£1,488.98

EACH

Datasheet
3VA2340-0HL42-0AA0
3VA2340-0HL42-0AA0
3VA2340-0HL42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A ... 400A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 50% 100%) busbar connection

£2,022.15

EACH

Datasheet
3VA2340-0HM32-0AA0
3VA2340-0HM32-0AA0
3VA2340-0HM32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A ... 400A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s busbar connection

£1,671.05

EACH

Datasheet
3VA2340-0HM42-0AA0
3VA2340-0HM42-0AA0
3VA2340-0HM42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A ... 400A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF 50% 100%) ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s

£2,197.71

EACH

Datasheet
3VA2340-0HN32-0AA0
3VA2340-0HN32-0AA0
3VA2340-0HN32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=1,5...10xIr, Ii=12xIn busbar connection

£1,573.52

EACH

Datasheet
3VA2340-0HN42-0AA0
3VA2340-0HN42-0AA0
3VA2340-0HN42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=1,5...10xIr, Ii=12xIn neutral protection adjustable(OFF 50% 100%) busbar connection

£2,093.68

EACH

Datasheet
3VA2340-0KP32-0AA0
3VA2340-0KP32-0AA0
3VA2340-0KP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn busbar connection

£2,035.16

EACH

Datasheet
3VA2340-0KP42-0AA0
3VA2340-0KP42-0AA0
3VA2340-0KP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 100%) busbar connection

£2,555.33

EACH

Datasheet
3VA2340-0KQ32-0AA0
3VA2340-0KQ32-0AA0
3VA2340-0KQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn busbar connection

£2,139.20

EACH

Datasheet
3VA2340-0KQ42-0AA0
3VA2340-0KQ42-0AA0
3VA2340-0KQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A ... 400A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 100%) busbar connection

£2,665.86

EACH

Datasheet
3VA2340-5HL32-0AA0
3VA2340-5HL32-0AA0
3VA2340-5HL32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit

£805.80

EACH

Datasheet
3VA2340-5HL32-0AB0
3VA2340-5HL32-0AB0
3VA2340-5HL32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£1,050.22

EACH

Datasheet
3VA2340-5HL32-0AC0
3VA2340-5HL32-0AC0
3VA2340-5HL32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£1,036.83

EACH

Datasheet
3VA2340-5HL32-0AD0
3VA2340-5HL32-0AD0
3VA2340-5HL32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£1,050.22

EACH

Datasheet
3VA2340-5HL32-0AE0
3VA2340-5HL32-0AE0
3VA2340-5HL32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£1,118.49

EACH

Datasheet
3VA2340-5HL32-0AF0
3VA2340-5HL32-0AF0
3VA2340-5HL32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,036.83

EACH

Datasheet
3VA2340-5HL32-0AG0
3VA2340-5HL32-0AG0
3VA2340-5HL32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,050.22

EACH

Datasheet
3VA2340-5HL32-0AH0
3VA2340-5HL32-0AH0
3VA2340-5HL32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,050.22

EACH

Datasheet
3VA2340-5HL32-0AJ0
3VA2340-5HL32-0AJ0
3VA2340-5HL32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,076.96

EACH

Datasheet
3VA2340-5HL32-0BA0
3VA2340-5HL32-0BA0
3VA2340-5HL32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,076.96

EACH

Datasheet
3VA2340-5HL32-0BB0
3VA2340-5HL32-0BB0
3VA2340-5HL32-0BB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HP

£1,143.86

EACH

Datasheet
3VA2340-5HL32-0BC0
3VA2340-5HL32-0BC0
3VA2340-5HL32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,110.41

EACH

Datasheet
3VA2340-5HL32-0BF0
3VA2340-5HL32-0BF0
3VA2340-5HL32-0BF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0BH0
3VA2340-5HL32-0BH0
3VA2340-5HL32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2340-5HL32-0BK0
3VA2340-5HL32-0BK0
3VA2340-5HL32-0BK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2340-5HL32-0BL0
3VA2340-5HL32-0BL0
3VA2340-5HL32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2340-5HL32-0CA0
3VA2340-5HL32-0CA0
3VA2340-5HL32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,076.96

EACH

Datasheet
3VA2340-5HL32-0CC0
3VA2340-5HL32-0CC0
3VA2340-5HL32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0CH0
3VA2340-5HL32-0CH0
3VA2340-5HL32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2340-5HL32-0CL0
3VA2340-5HL32-0CL0
3VA2340-5HL32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2340-5HL32-0DA0
3VA2340-5HL32-0DA0
3VA2340-5HL32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,076.96

EACH

Datasheet
3VA2340-5HL32-0DC0
3VA2340-5HL32-0DC0
3VA2340-5HL32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0DF0
3VA2340-5HL32-0DF0
3VA2340-5HL32-0DF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0DH0
3VA2340-5HL32-0DH0
3VA2340-5HL32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,137.16

EACH

Datasheet
3VA2340-5HL32-0DL0
3VA2340-5HL32-0DL0
3VA2340-5HL32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,163.92

EACH

Datasheet
3VA2340-5HL32-0HA0
3VA2340-5HL32-0HA0
3VA2340-5HL32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2340-5HL32-0HC0
3VA2340-5HL32-0HC0
3VA2340-5HL32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2340-5HL32-0HH0
3VA2340-5HL32-0HH0
3VA2340-5HL32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0HK0
3VA2340-5HL32-0HK0
3VA2340-5HL32-0HK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit SHUNT TRIP LEFT 24 V AC 50/60 HZ / 24-30 V DC ACCESSORY FOR 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,112.00

EACH

Datasheet
3VA2340-5HL32-0HL0
3VA2340-5HL32-0HL0
3VA2340-5HL32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2340-5HL32-0JA0
3VA2340-5HL32-0JA0
3VA2340-5HL32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,111.46

EACH

Datasheet
3VA2340-5HL32-0JC0
3VA2340-5HL32-0JC0
3VA2340-5HL32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2340-5HL32-0JH0
3VA2340-5HL32-0JH0
3VA2340-5HL32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0JL0
3VA2340-5HL32-0JL0
3VA2340-5HL32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2340-5HL32-0KA0
3VA2340-5HL32-0KA0
3VA2340-5HL32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,111.46

EACH

Datasheet
3VA2340-5HL32-0KB0
3VA2340-5HL32-0KB0
3VA2340-5HL32-0KB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H

£1,112.00

EACH

Datasheet
3VA2340-5HL32-0KC0
3VA2340-5HL32-0KC0
3VA2340-5HL32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,097.04

EACH

Datasheet
3VA2340-5HL32-0KH0
3VA2340-5HL32-0KH0
3VA2340-5HL32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,117.10

EACH

Datasheet
3VA2340-5HL32-0KK0
3VA2340-5HL32-0KK0
3VA2340-5HL32-0KK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,118.36

EACH

Datasheet
3VA2340-5HL32-0KL0
3VA2340-5HL32-0KL0
3VA2340-5HL32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,143.86

EACH

Datasheet
3VA2340-5HL42-0AA0
3VA2340-5HL42-0AA0
3VA2340-5HL42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,072.75

EACH

Datasheet
3VA2340-5HL42-0AB0
3VA2340-5HL42-0AB0
3VA2340-5HL42-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP

£1,364.61

EACH

Datasheet
3VA2340-5HL42-0AC0
3VA2340-5HL42-0AC0
3VA2340-5HL42-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ

£1,351.22

EACH

Datasheet
3VA2340-5HL42-0AD0
3VA2340-5HL42-0AD0
3VA2340-5HL42-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 3 auxiliary switches HQ

£1,364.61

EACH

Datasheet
3VA2340-5HL42-0AE0
3VA2340-5HL42-0AE0
3VA2340-5HL42-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 4 auxiliary switches HQ

£1,377.98

EACH

Datasheet
3VA2340-5HL42-0AF0
3VA2340-5HL42-0AF0
3VA2340-5HL42-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,351.22

EACH

Datasheet
3VA2340-5HL42-0AG0
3VA2340-5HL42-0AG0
3VA2340-5HL42-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,364.61

EACH

Datasheet
3VA2340-5HL42-0AH0
3VA2340-5HL42-0AH0
3VA2340-5HL42-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,364.61

EACH

Datasheet
3VA2340-5HL42-0AJ0
3VA2340-5HL42-0AJ0
3VA2340-5HL42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,391.36

EACH

Datasheet
3VA2340-5HL42-0BA0
3VA2340-5HL42-0BA0
3VA2340-5HL42-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC

£1,391.36

EACH

Datasheet
3VA2340-5HL42-0BC0
3VA2340-5HL42-0BC0
3VA2340-5HL42-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0BH0
3VA2340-5HL42-0BH0
3VA2340-5HL42-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,444.88

EACH

Datasheet
3VA2340-5HL42-0BL0
3VA2340-5HL42-0BL0
3VA2340-5HL42-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,471.63

EACH

Datasheet
3VA2340-5HL42-0CA0
3VA2340-5HL42-0CA0
3VA2340-5HL42-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,391.36

EACH

Datasheet
3VA2340-5HL42-0CC0
3VA2340-5HL42-0CC0
3VA2340-5HL42-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0CH0
3VA2340-5HL42-0CH0
3VA2340-5HL42-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,444.88

EACH

Datasheet
3VA2340-5HL42-0CL0
3VA2340-5HL42-0CL0
3VA2340-5HL42-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,471.63

EACH

Datasheet
3VA2340-5HL42-0DA0
3VA2340-5HL42-0DA0
3VA2340-5HL42-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,391.36

EACH

Datasheet
3VA2340-5HL42-0DC0
3VA2340-5HL42-0DC0
3VA2340-5HL42-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0DF0
3VA2340-5HL42-0DF0
3VA2340-5HL42-0DF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0DH0
3VA2340-5HL42-0DH0
3VA2340-5HL42-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,444.88

EACH

Datasheet
3VA2340-5HL42-0DL0
3VA2340-5HL42-0DL0
3VA2340-5HL42-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,471.63

EACH

Datasheet
3VA2340-5HL42-0HA0
3VA2340-5HL42-0HA0
3VA2340-5HL42-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,371.29

EACH

Datasheet
3VA2340-5HL42-0HC0
3VA2340-5HL42-0HC0
3VA2340-5HL42-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,404.73

EACH

Datasheet
3VA2340-5HL42-0HH0
3VA2340-5HL42-0HH0
3VA2340-5HL42-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0HL0
3VA2340-5HL42-0HL0
3VA2340-5HL42-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,451.55

EACH

Datasheet
3VA2340-5HL42-0JA0
3VA2340-5HL42-0JA0
3VA2340-5HL42-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,371.29

EACH

Datasheet
3VA2340-5HL42-0JC0
3VA2340-5HL42-0JC0
3VA2340-5HL42-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,404.73

EACH

Datasheet
3VA2340-5HL42-0JH0
3VA2340-5HL42-0JH0
3VA2340-5HL42-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0JL0
3VA2340-5HL42-0JL0
3VA2340-5HL42-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,451.55

EACH

Datasheet
3VA2340-5HL42-0KA0
3VA2340-5HL42-0KA0
3VA2340-5HL42-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,371.29

EACH

Datasheet
3VA2340-5HL42-0KB0
3VA2340-5HL42-0KB0
3VA2340-5HL42-0KB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 shunt trip left 208-277V AC 50/60Hz 2 auxiliary switches HP

£1,371.29

EACH

Datasheet
3VA2340-5HL42-0KC0
3VA2340-5HL42-0KC0
3VA2340-5HL42-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,404.73

EACH

Datasheet
3VA2340-5HL42-0KH0
3VA2340-5HL42-0KH0
3VA2340-5HL42-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-5HL42-0KL0
3VA2340-5HL42-0KL0
3VA2340-5HL42-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,451.55

EACH

Datasheet
3VA2340-5HM32-0AA0
3VA2340-5HM32-0AA0
3VA2340-5HM32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,021.63

EACH

Datasheet
3VA2340-5HM42-0AA0
3VA2340-5HM42-0AA0
3VA2340-5HM42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,280.64

EACH

Datasheet
3VA2340-5HN32-0AA0
3VA2340-5HN32-0AA0
3VA2340-5HN32-0AA0Incoming Device 400A 3P MCCB

£1,133.68

EACH

Catalogue
Datasheet
3VA2340-5HN32-0AB0
3VA2340-5HN32-0AB0
3VA2340-5HN32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£1,123.79

EACH

Datasheet
3VA2340-5HN32-0AC0
3VA2340-5HN32-0AC0
3VA2340-5HN32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£1,110.41

EACH

Datasheet
3VA2340-5HN32-0AD0
3VA2340-5HN32-0AD0
3VA2340-5HN32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£1,123.79

EACH

Datasheet
3VA2340-5HN32-0AE0
3VA2340-5HN32-0AE0
3VA2340-5HN32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£1,143.86

EACH

Datasheet
3VA2340-5HN32-0AF0
3VA2340-5HN32-0AF0
3VA2340-5HN32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,110.41

EACH

Datasheet
3VA2340-5HN32-0AG0
3VA2340-5HN32-0AG0
3VA2340-5HN32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,123.79

EACH

Datasheet
3VA2340-5HN32-0AH0
3VA2340-5HN32-0AH0
3VA2340-5HN32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,123.79

EACH

Datasheet
3VA2340-5HN32-0AJ0
3VA2340-5HN32-0AJ0
3VA2340-5HN32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,157.23

EACH

Datasheet
3VA2340-5HN32-0BA0
3VA2340-5HN32-0BA0
3VA2340-5HN32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,157.23

EACH

Datasheet
3VA2340-5HN32-0BC0
3VA2340-5HN32-0BC0
3VA2340-5HN32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0BF0
3VA2340-5HN32-0BF0
3VA2340-5HN32-0BF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V undervoltage release 24V DC 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,150.55

EACH

Datasheet
3VA2340-5HN32-0BH0
3VA2340-5HN32-0BH0
3VA2340-5HN32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,273.25

EACH

Datasheet
3VA2340-5HN32-0BL0
3VA2340-5HN32-0BL0
3VA2340-5HN32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,237.50

EACH

Datasheet
3VA2340-5HN32-0CA0
3VA2340-5HN32-0CA0
3VA2340-5HN32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,157.23

EACH

Datasheet
3VA2340-5HN32-0CC0
3VA2340-5HN32-0CC0
3VA2340-5HN32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0CH0
3VA2340-5HN32-0CH0
3VA2340-5HN32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,273.25

EACH

Datasheet
3VA2340-5HN32-0CL0
3VA2340-5HN32-0CL0
3VA2340-5HN32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,237.50

EACH

Datasheet
3VA2340-5HN32-0DA0
3VA2340-5HN32-0DA0
3VA2340-5HN32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,157.23

EACH

Datasheet
3VA2340-5HN32-0DC0
3VA2340-5HN32-0DC0
3VA2340-5HN32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0DF0
3VA2340-5HN32-0DF0
3VA2340-5HN32-0DF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,189.84

EACH

Datasheet
3VA2340-5HN32-0DH0
3VA2340-5HN32-0DH0
3VA2340-5HN32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,273.25

EACH

Datasheet
3VA2340-5HN32-0DJ0
3VA2340-5HN32-0DJ0
3VA2340-5HN32-0DJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,239.88

EACH

Datasheet
3VA2340-5HN32-0DK0
3VA2340-5HN32-0DK0
3VA2340-5HN32-0DK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V undervoltage release 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,217.43

EACH

Datasheet
3VA2340-5HN32-0DL0
3VA2340-5HN32-0DL0
3VA2340-5HN32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,237.50

EACH

Datasheet
3VA2340-5HN32-0HA0
3VA2340-5HN32-0HA0
3VA2340-5HN32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,137.16

EACH

Datasheet
3VA2340-5HN32-0HC0
3VA2340-5HN32-0HC0
3VA2340-5HN32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,170.61

EACH

Datasheet
3VA2340-5HN32-0HH0
3VA2340-5HN32-0HH0
3VA2340-5HN32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0HK0
3VA2340-5HN32-0HK0
3VA2340-5HN32-0HK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, SHUNT TRIP LEFT 24 V AC 50/60 HZ / 24-30 V DC ACCESSORY FOR 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,258.15

EACH

Datasheet
3VA2340-5HN32-0HL0
3VA2340-5HN32-0HL0
3VA2340-5HN32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,217.43

EACH

Datasheet
3VA2340-5HN32-0JA0
3VA2340-5HN32-0JA0
3VA2340-5HN32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,137.16

EACH

Datasheet
3VA2340-5HN32-0JC0
3VA2340-5HN32-0JC0
3VA2340-5HN32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,170.61

EACH

Datasheet
3VA2340-5HN32-0JH0
3VA2340-5HN32-0JH0
3VA2340-5HN32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0JL0
3VA2340-5HN32-0JL0
3VA2340-5HN32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,217.43

EACH

Datasheet
3VA2340-5HN32-0KA0
3VA2340-5HN32-0KA0
3VA2340-5HN32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,137.16

EACH

Datasheet
3VA2340-5HN32-0KB0
3VA2340-5HN32-0KB0
3VA2340-5HN32-0KB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection ISD=1.5...10xIR, Ii=10xIn nut keeper kit shunt trip left 208-277V AC 50/60Hz 2 auxiliary switches

£1,190.68

EACH

Datasheet
3VA2340-5HN32-0KC0
3VA2340-5HN32-0KC0
3VA2340-5HN32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,170.61

EACH

Datasheet
3VA2340-5HN32-0KE0
3VA2340-5HN32-0KE0
3VA2340-5HN32-0KE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 4 auxiliary switches HQ

£1,273.25

EACH

Datasheet
3VA2340-5HN32-0KF0
3VA2340-5HN32-0KF0
3VA2340-5HN32-0KF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip left 208-277V AC 50/60Hz 1 auxiliary switch 1 trip alarm switch

£1,177.30

EACH

Datasheet
3VA2340-5HN32-0KG0
3VA2340-5HN32-0KG0
3VA2340-5HN32-0KG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip left 208-277V AC 50/60Hz 1 auxiliary switch 1 trip alarm switch

£1,190.68

EACH

Datasheet
3VA2340-5HN32-0KH0
3VA2340-5HN32-0KH0
3VA2340-5HN32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,259.17

EACH

Datasheet
3VA2340-5HN32-0KJ0
3VA2340-5HN32-0KJ0
3VA2340-5HN32-0KJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,217.43

EACH

Datasheet
3VA2340-5HN32-0KK0
3VA2340-5HN32-0KK0
3VA2340-5HN32-0KK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,258.15

EACH

Datasheet
3VA2340-5HN32-0KL0
3VA2340-5HN32-0KL0
3VA2340-5HN32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,217.43

EACH

Datasheet
3VA2340-5HN32-0LC0
3VA2340-5HN32-0LC0
3VA2340-5HN32-0LC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H

£1,256.56

EACH

Datasheet
3VA2340-5HN32-0LL0
3VA2340-5HN32-0LL0
3VA2340-5HN32-0LL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,297.89

EACH

Datasheet
3VA2340-5HN42-0AA0
3VA2340-5HN42-0AA0
3VA2340-5HN42-0AA0400A 4P MCCB

£1,244.47

EACH

Catalogue
Datasheet
3VA2340-5HN42-0AB0
3VA2340-5HN42-0AB0
3VA2340-5HN42-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP

£1,438.18

EACH

Datasheet
3VA2340-5HN42-0AC0
3VA2340-5HN42-0AC0
3VA2340-5HN42-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2340-5HN42-0AD0
3VA2340-5HN42-0AD0
3VA2340-5HN42-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 3 auxiliary switches HQ

£1,438.18

EACH

Datasheet
3VA2340-5HN42-0AE0
3VA2340-5HN42-0AE0
3VA2340-5HN42-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 4 auxiliary switches HQ

£1,451.55

EACH

Datasheet
3VA2340-5HN42-0AF0
3VA2340-5HN42-0AF0
3VA2340-5HN42-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2340-5HN42-0AG0
3VA2340-5HN42-0AG0
3VA2340-5HN42-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,438.18

EACH

Datasheet
3VA2340-5HN42-0AH0
3VA2340-5HN42-0AH0
3VA2340-5HN42-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2340-5HN42-0AJ0
3VA2340-5HN42-0AJ0
3VA2340-5HN42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,464.93

EACH

Datasheet
3VA2340-5HN42-0BA0
3VA2340-5HN42-0BA0
3VA2340-5HN42-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC

£1,464.93

EACH

Datasheet
3VA2340-5HN42-0BC0
3VA2340-5HN42-0BC0
3VA2340-5HN42-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0BH0
3VA2340-5HN42-0BH0
3VA2340-5HN42-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5HN42-0BL0
3VA2340-5HN42-0BL0
3VA2340-5HN42-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5HN42-0CA0
3VA2340-5HN42-0CA0
3VA2340-5HN42-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,464.93

EACH

Datasheet
3VA2340-5HN42-0CC0
3VA2340-5HN42-0CC0
3VA2340-5HN42-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0CH0
3VA2340-5HN42-0CH0
3VA2340-5HN42-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5HN42-0CL0
3VA2340-5HN42-0CL0
3VA2340-5HN42-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5HN42-0DA0
3VA2340-5HN42-0DA0
3VA2340-5HN42-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,464.93

EACH

Datasheet
3VA2340-5HN42-0DC0
3VA2340-5HN42-0DC0
3VA2340-5HN42-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0DH0
3VA2340-5HN42-0DH0
3VA2340-5HN42-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5HN42-0DL0
3VA2340-5HN42-0DL0
3VA2340-5HN42-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5HN42-0HA0
3VA2340-5HN42-0HA0
3VA2340-5HN42-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,444.88

EACH

Datasheet
3VA2340-5HN42-0HC0
3VA2340-5HN42-0HC0
3VA2340-5HN42-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5HN42-0HH0
3VA2340-5HN42-0HH0
3VA2340-5HN42-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0HL0
3VA2340-5HN42-0HL0
3VA2340-5HN42-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5HN42-0JA0
3VA2340-5HN42-0JA0
3VA2340-5HN42-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,444.88

EACH

Datasheet
3VA2340-5HN42-0JC0
3VA2340-5HN42-0JC0
3VA2340-5HN42-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5HN42-0JH0
3VA2340-5HN42-0JH0
3VA2340-5HN42-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0JL0
3VA2340-5HN42-0JL0
3VA2340-5HN42-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5HN42-0KA0
3VA2340-5HN42-0KA0
3VA2340-5HN42-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,444.88

EACH

Datasheet
3VA2340-5HN42-0KC0
3VA2340-5HN42-0KC0
3VA2340-5HN42-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5HN42-0KH0
3VA2340-5HN42-0KH0
3VA2340-5HN42-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5HN42-0KL0
3VA2340-5HN42-0KL0
3VA2340-5HN42-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5HN42-0LH0
3VA2340-5HN42-0LH0
3VA2340-5HN42-0LH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,584.60

EACH

Datasheet
3VA2340-5JP32-0AA0
3VA2340-5JP32-0AA0
3VA2340-5JP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,448.90

EACH

Datasheet
3VA2340-5JP32-0AB0
3VA2340-5JP32-0AB0
3VA2340-5JP32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP

£1,438.18

EACH

Datasheet
3VA2340-5JP32-0AC0
3VA2340-5JP32-0AC0
3VA2340-5JP32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ

£1,418.11

EACH

Datasheet
3VA2340-5JP32-0AD0
3VA2340-5JP32-0AD0
3VA2340-5JP32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 3 auxiliary switches HQ

£1,438.18

EACH

Datasheet
3VA2340-5JP32-0AE0
3VA2340-5JP32-0AE0
3VA2340-5JP32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 4 auxiliary switches HQ

£1,451.55

EACH

Datasheet
3VA2340-5JP32-0AF0
3VA2340-5JP32-0AF0
3VA2340-5JP32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,418.11

EACH

Datasheet
3VA2340-5JP32-0AG0
3VA2340-5JP32-0AG0
3VA2340-5JP32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,438.18

EACH

Datasheet
3VA2340-5JP32-0AH0
3VA2340-5JP32-0AH0
3VA2340-5JP32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,438.18

EACH

Datasheet
3VA2340-5JP32-0AJ0
3VA2340-5JP32-0AJ0
3VA2340-5JP32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,464.93

EACH

Datasheet
3VA2340-5JP32-0BA0
3VA2340-5JP32-0BA0
3VA2340-5JP32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC

£1,464.93

EACH

Datasheet
3VA2340-5JP32-0BC0
3VA2340-5JP32-0BC0
3VA2340-5JP32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0BH0
3VA2340-5JP32-0BH0
3VA2340-5JP32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5JP32-0BL0
3VA2340-5JP32-0BL0
3VA2340-5JP32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5JP32-0CA0
3VA2340-5JP32-0CA0
3VA2340-5JP32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,464.93

EACH

Datasheet
3VA2340-5JP32-0CC0
3VA2340-5JP32-0CC0
3VA2340-5JP32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0CH0
3VA2340-5JP32-0CH0
3VA2340-5JP32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5JP32-0CL0
3VA2340-5JP32-0CL0
3VA2340-5JP32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5JP32-0DA0
3VA2340-5JP32-0DA0
3VA2340-5JP32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,464.93

EACH

Datasheet
3VA2340-5JP32-0DC0
3VA2340-5JP32-0DC0
3VA2340-5JP32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0DF0
3VA2340-5JP32-0DF0
3VA2340-5JP32-0DF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC undervoltage release 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0DH0
3VA2340-5JP32-0DH0
3VA2340-5JP32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,518.45

EACH

Datasheet
3VA2340-5JP32-0DL0
3VA2340-5JP32-0DL0
3VA2340-5JP32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,551.89

EACH

Datasheet
3VA2340-5JP32-0HA0
3VA2340-5JP32-0HA0
3VA2340-5JP32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,444.88

EACH

Datasheet
3VA2340-5JP32-0HC0
3VA2340-5JP32-0HC0
3VA2340-5JP32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5JP32-0HH0
3VA2340-5JP32-0HH0
3VA2340-5JP32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0HL0
3VA2340-5JP32-0HL0
3VA2340-5JP32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5JP32-0JA0
3VA2340-5JP32-0JA0
3VA2340-5JP32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,444.88

EACH

Datasheet
3VA2340-5JP32-0JC0
3VA2340-5JP32-0JC0
3VA2340-5JP32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5JP32-0JH0
3VA2340-5JP32-0JH0
3VA2340-5JP32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0JL0
3VA2340-5JP32-0JL0
3VA2340-5JP32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5JP32-0KA0
3VA2340-5JP32-0KA0
3VA2340-5JP32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,444.88

EACH

Datasheet
3VA2340-5JP32-0KC0
3VA2340-5JP32-0KC0
3VA2340-5JP32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,478.32

EACH

Datasheet
3VA2340-5JP32-0KH0
3VA2340-5JP32-0KH0
3VA2340-5JP32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,505.07

EACH

Datasheet
3VA2340-5JP32-0KL0
3VA2340-5JP32-0KL0
3VA2340-5JP32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,525.14

EACH

Datasheet
3VA2340-5JP42-0AA0
3VA2340-5JP42-0AA0
3VA2340-5JP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,718.40

EACH

Datasheet
3VA2340-5JQ32-0AA0
3VA2340-5JQ32-0AA0
3VA2340-5JQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,185.90

EACH

Datasheet
3VA2340-5JQ32-0AB0
3VA2340-5JQ32-0AB0
3VA2340-5JQ32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP

£1,625.48

EACH

Datasheet
3VA2340-5JQ32-0AC0
3VA2340-5JQ32-0AC0
3VA2340-5JQ32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ

£1,605.41

EACH

Datasheet
3VA2340-5JQ32-0AD0
3VA2340-5JQ32-0AD0
3VA2340-5JQ32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ

£1,625.48

EACH

Datasheet
3VA2340-5JQ32-0AE0
3VA2340-5JQ32-0AE0
3VA2340-5JQ32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 4 auxiliary switches HQ

£1,638.87

EACH

Datasheet
3VA2340-5JQ32-0AF0
3VA2340-5JQ32-0AF0
3VA2340-5JQ32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,605.41

EACH

Datasheet
3VA2340-5JQ32-0AG0
3VA2340-5JQ32-0AG0
3VA2340-5JQ32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,625.48

EACH

Datasheet
3VA2340-5JQ32-0AH0
3VA2340-5JQ32-0AH0
3VA2340-5JQ32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,625.48

EACH

Datasheet
3VA2340-5JQ32-0AJ0
3VA2340-5JQ32-0AJ0
3VA2340-5JQ32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,652.24

EACH

Datasheet
3VA2340-5JQ32-0BA0
3VA2340-5JQ32-0BA0
3VA2340-5JQ32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC

£1,652.24

EACH

Datasheet
3VA2340-5JQ32-0BC0
3VA2340-5JQ32-0BC0
3VA2340-5JQ32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0BH0
3VA2340-5JQ32-0BH0
3VA2340-5JQ32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,712.44

EACH

Datasheet
3VA2340-5JQ32-0BL0
3VA2340-5JQ32-0BL0
3VA2340-5JQ32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,745.88

EACH

Datasheet
3VA2340-5JQ32-0CA0
3VA2340-5JQ32-0CA0
3VA2340-5JQ32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,652.24

EACH

Datasheet
3VA2340-5JQ32-0CC0
3VA2340-5JQ32-0CC0
3VA2340-5JQ32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0CH0
3VA2340-5JQ32-0CH0
3VA2340-5JQ32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,712.44

EACH

Datasheet
3VA2340-5JQ32-0CL0
3VA2340-5JQ32-0CL0
3VA2340-5JQ32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,745.88

EACH

Datasheet
3VA2340-5JQ32-0DA0
3VA2340-5JQ32-0DA0
3VA2340-5JQ32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,652.24

EACH

Datasheet
3VA2340-5JQ32-0DC0
3VA2340-5JQ32-0DC0
3VA2340-5JQ32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0DH0
3VA2340-5JQ32-0DH0
3VA2340-5JQ32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,712.44

EACH

Datasheet
3VA2340-5JQ32-0DL0
3VA2340-5JQ32-0DL0
3VA2340-5JQ32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,745.88

EACH

Datasheet
3VA2340-5JQ32-0HA0
3VA2340-5JQ32-0HA0
3VA2340-5JQ32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,632.16

EACH

Datasheet
3VA2340-5JQ32-0HC0
3VA2340-5JQ32-0HC0
3VA2340-5JQ32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,665.62

EACH

Datasheet
3VA2340-5JQ32-0HH0
3VA2340-5JQ32-0HH0
3VA2340-5JQ32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0HL0
3VA2340-5JQ32-0HL0
3VA2340-5JQ32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, IN=400A overload protection Ir=160A ...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,719.13

EACH

Datasheet
3VA2340-5JQ32-0JA0
3VA2340-5JQ32-0JA0
3VA2340-5JQ32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,632.16

EACH

Datasheet
3VA2340-5JQ32-0JC0
3VA2340-5JQ32-0JC0
3VA2340-5JQ32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,665.62

EACH

Datasheet
3VA2340-5JQ32-0JH0
3VA2340-5JQ32-0JH0
3VA2340-5JQ32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0JL0
3VA2340-5JQ32-0JL0
3VA2340-5JQ32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,719.13

EACH

Datasheet
3VA2340-5JQ32-0KA0
3VA2340-5JQ32-0KA0
3VA2340-5JQ32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,632.16

EACH

Datasheet
3VA2340-5JQ32-0KC0
3VA2340-5JQ32-0KC0
3VA2340-5JQ32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,665.62

EACH

Datasheet
3VA2340-5JQ32-0KH0
3VA2340-5JQ32-0KH0
3VA2340-5JQ32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,692.36

EACH

Datasheet
3VA2340-5JQ32-0KL0
3VA2340-5JQ32-0KL0
3VA2340-5JQ32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,719.13

EACH

Datasheet
3VA2340-5JQ42-0AA0
3VA2340-5JQ42-0AA0
3VA2340-5JQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,908.55

EACH

Datasheet
3VA2340-5JQ42-0AB0
3VA2340-5JQ42-0AB0
3VA2340-5JQ42-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP

£1,933.18

EACH

Datasheet
3VA2340-5JQ42-0AC0
3VA2340-5JQ42-0AC0
3VA2340-5JQ42-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ

£1,919.79

EACH

Datasheet
3VA2340-5JQ42-0AD0
3VA2340-5JQ42-0AD0
3VA2340-5JQ42-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ

£1,933.18

EACH

Datasheet
3VA2340-5JQ42-0AE0
3VA2340-5JQ42-0AE0
3VA2340-5JQ42-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 4 auxiliary switches HQ

£1,953.25

EACH

Datasheet
3VA2340-5JQ42-0AF0
3VA2340-5JQ42-0AF0
3VA2340-5JQ42-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,919.79

EACH

Datasheet
3VA2340-5JQ42-0AG0
3VA2340-5JQ42-0AG0
3VA2340-5JQ42-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,933.18

EACH

Datasheet
3VA2340-5JQ42-0AH0
3VA2340-5JQ42-0AH0
3VA2340-5JQ42-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,933.18

EACH

Datasheet
3VA2340-5JQ42-0AJ0
3VA2340-5JQ42-0AJ0
3VA2340-5JQ42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,973.32

EACH

Datasheet
3VA2340-5JQ42-0AK0
3VA2340-5JQ42-0AK0
3VA2340-5JQ42-0AK0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,937.33

EACH

Datasheet
3VA2340-5JQ42-0BA0
3VA2340-5JQ42-0BA0
3VA2340-5JQ42-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC

£1,973.32

EACH

Datasheet
3VA2340-5JQ42-0BC0
3VA2340-5JQ42-0BC0
3VA2340-5JQ42-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0BH0
3VA2340-5JQ42-0BH0
3VA2340-5JQ42-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,020.14

EACH

Datasheet
3VA2340-5JQ42-0BL0
3VA2340-5JQ42-0BL0
3VA2340-5JQ42-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,046.90

EACH

Datasheet
3VA2340-5JQ42-0CA0
3VA2340-5JQ42-0CA0
3VA2340-5JQ42-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,973.32

EACH

Datasheet
3VA2340-5JQ42-0CC0
3VA2340-5JQ42-0CC0
3VA2340-5JQ42-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0CH0
3VA2340-5JQ42-0CH0
3VA2340-5JQ42-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,020.14

EACH

Datasheet
3VA2340-5JQ42-0CL0
3VA2340-5JQ42-0CL0
3VA2340-5JQ42-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,046.90

EACH

Datasheet
3VA2340-5JQ42-0DA0
3VA2340-5JQ42-0DA0
3VA2340-5JQ42-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,973.32

EACH

Datasheet
3VA2340-5JQ42-0DC0
3VA2340-5JQ42-0DC0
3VA2340-5JQ42-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0DH0
3VA2340-5JQ42-0DH0
3VA2340-5JQ42-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,020.14

EACH

Datasheet
3VA2340-5JQ42-0DL0
3VA2340-5JQ42-0DL0
3VA2340-5JQ42-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,046.90

EACH

Datasheet
3VA2340-5JQ42-0HA0
3VA2340-5JQ42-0HA0
3VA2340-5JQ42-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,939.87

EACH

Datasheet
3VA2340-5JQ42-0HC0
3VA2340-5JQ42-0HC0
3VA2340-5JQ42-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,986.69

EACH

Datasheet
3VA2340-5JQ42-0HH0
3VA2340-5JQ42-0HH0
3VA2340-5JQ42-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0HL0
3VA2340-5JQ42-0HL0
3VA2340-5JQ42-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,026.84

EACH

Datasheet
3VA2340-5JQ42-0JA0
3VA2340-5JQ42-0JA0
3VA2340-5JQ42-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,939.87

EACH

Datasheet
3VA2340-5JQ42-0JC0
3VA2340-5JQ42-0JC0
3VA2340-5JQ42-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,986.69

EACH

Datasheet
3VA2340-5JQ42-0JH0
3VA2340-5JQ42-0JH0
3VA2340-5JQ42-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0JL0
3VA2340-5JQ42-0JL0
3VA2340-5JQ42-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,026.84

EACH

Datasheet
3VA2340-5JQ42-0KA0
3VA2340-5JQ42-0KA0
3VA2340-5JQ42-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,939.87

EACH

Datasheet
3VA2340-5JQ42-0KC0
3VA2340-5JQ42-0KC0
3VA2340-5JQ42-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,986.69

EACH

Datasheet
3VA2340-5JQ42-0KH0
3VA2340-5JQ42-0KH0
3VA2340-5JQ42-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,006.76

EACH

Datasheet
3VA2340-5JQ42-0KL0
3VA2340-5JQ42-0KL0
3VA2340-5JQ42-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,026.84

EACH

Datasheet
3VA2340-5KP32-0AA0
3VA2340-5KP32-0AA0
3VA2340-5KP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,376.96

EACH

Datasheet
3VA2340-5KP32-0AB0
3VA2340-5KP32-0AB0
3VA2340-5KP32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP

£1,585.34

EACH

Datasheet
3VA2340-5KP32-0AC0
3VA2340-5KP32-0AC0
3VA2340-5KP32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ

£1,571.96

EACH

Datasheet
3VA2340-5KP32-0AD0
3VA2340-5KP32-0AD0
3VA2340-5KP32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 3 auxiliary switches HQ

£1,585.34

EACH

Datasheet
3VA2340-5KP32-0AE0
3VA2340-5KP32-0AE0
3VA2340-5KP32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 4 auxiliary switches HQ

£1,598.71

EACH

Datasheet
3VA2340-5KP32-0AF0
3VA2340-5KP32-0AF0
3VA2340-5KP32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,571.96

EACH

Datasheet
3VA2340-5KP32-0AG0
3VA2340-5KP32-0AG0
3VA2340-5KP32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,585.34

EACH

Datasheet
3VA2340-5KP32-0AH0
3VA2340-5KP32-0AH0
3VA2340-5KP32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,585.34

EACH

Datasheet
3VA2340-5KP32-0AJ0
3VA2340-5KP32-0AJ0
3VA2340-5KP32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,618.78

EACH

Datasheet
3VA2340-5KP32-0AL0
3VA2340-5KP32-0AL0
3VA2340-5KP32-0AL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,606.84

EACH

Datasheet
3VA2340-5KP32-0BA0
3VA2340-5KP32-0BA0
3VA2340-5KP32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC

£1,618.78

EACH

Datasheet
3VA2340-5KP32-0BC0
3VA2340-5KP32-0BC0
3VA2340-5KP32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0BH0
3VA2340-5KP32-0BH0
3VA2340-5KP32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,665.62

EACH

Datasheet
3VA2340-5KP32-0BL0
3VA2340-5KP32-0BL0
3VA2340-5KP32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,705.75

EACH

Datasheet
3VA2340-5KP32-0CA0
3VA2340-5KP32-0CA0
3VA2340-5KP32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,618.78

EACH

Datasheet
3VA2340-5KP32-0CC0
3VA2340-5KP32-0CC0
3VA2340-5KP32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0CH0
3VA2340-5KP32-0CH0
3VA2340-5KP32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,665.62

EACH

Datasheet
3VA2340-5KP32-0CL0
3VA2340-5KP32-0CL0
3VA2340-5KP32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,705.75

EACH

Datasheet
3VA2340-5KP32-0DA0
3VA2340-5KP32-0DA0
3VA2340-5KP32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,618.78

EACH

Datasheet
3VA2340-5KP32-0DC0
3VA2340-5KP32-0DC0
3VA2340-5KP32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0DH0
3VA2340-5KP32-0DH0
3VA2340-5KP32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,665.62

EACH

Datasheet
3VA2340-5KP32-0DL0
3VA2340-5KP32-0DL0
3VA2340-5KP32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,705.75

EACH

Datasheet
3VA2340-5KP32-0HA0
3VA2340-5KP32-0HA0
3VA2340-5KP32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,592.04

EACH

Datasheet
3VA2340-5KP32-0HC0
3VA2340-5KP32-0HC0
3VA2340-5KP32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-5KP32-0HH0
3VA2340-5KP32-0HH0
3VA2340-5KP32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0HL0
3VA2340-5KP32-0HL0
3VA2340-5KP32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-5KP32-0JA0
3VA2340-5KP32-0JA0
3VA2340-5KP32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,592.04

EACH

Datasheet
3VA2340-5KP32-0JC0
3VA2340-5KP32-0JC0
3VA2340-5KP32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-5KP32-0JH0
3VA2340-5KP32-0JH0
3VA2340-5KP32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0JL0
3VA2340-5KP32-0JL0
3VA2340-5KP32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-5KP32-0KA0
3VA2340-5KP32-0KA0
3VA2340-5KP32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,592.04

EACH

Datasheet
3VA2340-5KP32-0KC0
3VA2340-5KP32-0KC0
3VA2340-5KP32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-5KP32-0KH0
3VA2340-5KP32-0KH0
3VA2340-5KP32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,652.24

EACH

Datasheet
3VA2340-5KP32-0KL0
3VA2340-5KP32-0KL0
3VA2340-5KP32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-5KP42-0AA0
3VA2340-5KP42-0AA0
3VA2340-5KP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,830.13

EACH

Datasheet
3VA2340-5KP42-0AL0
3VA2340-5KP42-0AL0
3VA2340-5KP42-0AL0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,926.49

EACH

Datasheet
3VA2340-5KP42-0DA0
3VA2340-5KP42-0DA0
3VA2340-5KP42-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1

£1,933.18

EACH

Datasheet
3VA2340-5KP42-0JC0
3VA2340-5KP42-0JC0
3VA2340-5KP42-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection SHUNT TRIP LEFT 110-127 V AC 50/60 HZ / DC ACCESSORY FOR 2 AUXILIARY SWITCH CHANGEOVER H

£1,944.14

EACH

Datasheet
3VA2340-5KQ32-0AA0
3VA2340-5KQ32-0AA0
3VA2340-5KQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,277.08

EACH

Datasheet
3VA2340-5KQ32-0AF0
3VA2340-5KQ32-0AF0
3VA2340-5KQ32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class M 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,684.04

EACH

Datasheet
3VA2340-5KQ32-0LC0
3VA2340-5KQ32-0LC0
3VA2340-5KQ32-0LC0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s universal release (UNI) 24V DC 2 auxiliary switches HQ

£1,826.15

EACH

Datasheet
3VA2340-5KQ42-0AA0
3VA2340-5KQ42-0AA0
3VA2340-5KQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£1,946.65

EACH

Datasheet
3VA2340-5KQ42-0CB0
3VA2340-5KQ42-0CB0
3VA2340-5KQ42-0CB0circuit breaker 3VA2 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release 120-127V AC 50/60Hz 2 auxiliary switches

£2,100.40

EACH

Datasheet
3VA2340-6HL32-0AA0
3VA2340-6HL32-0AA0
3VA2340-6HL32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit

£899.03

EACH

Datasheet
3VA2340-6HL32-0AB0
3VA2340-6HL32-0AB0
3VA2340-6HL32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£1,190.68

EACH

Datasheet
3VA2340-6HL32-0AC0
3VA2340-6HL32-0AC0
3VA2340-6HL32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£1,170.61

EACH

Datasheet
3VA2340-6HL32-0AD0
3VA2340-6HL32-0AD0
3VA2340-6HL32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£1,190.68

EACH

Datasheet
3VA2340-6HL32-0AE0
3VA2340-6HL32-0AE0
3VA2340-6HL32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£1,266.21

EACH

Datasheet
3VA2340-6HL32-0AF0
3VA2340-6HL32-0AF0
3VA2340-6HL32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,170.61

EACH

Datasheet
3VA2340-6HL32-0AG0
3VA2340-6HL32-0AG0
3VA2340-6HL32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,190.68

EACH

Datasheet
3VA2340-6HL32-0AH0
3VA2340-6HL32-0AH0
3VA2340-6HL32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,190.68

EACH

Datasheet
3VA2340-6HL32-0AJ0
3VA2340-6HL32-0AJ0
3VA2340-6HL32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,217.43

EACH

Datasheet
3VA2340-6HL32-0BA0
3VA2340-6HL32-0BA0
3VA2340-6HL32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,217.43

EACH

Datasheet
3VA2340-6HL32-0BC0
3VA2340-6HL32-0BC0
3VA2340-6HL32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0BH0
3VA2340-6HL32-0BH0
3VA2340-6HL32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,264.26

EACH

Datasheet
3VA2340-6HL32-0BL0
3VA2340-6HL32-0BL0
3VA2340-6HL32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,297.71

EACH

Datasheet
3VA2340-6HL32-0CA0
3VA2340-6HL32-0CA0
3VA2340-6HL32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,217.43

EACH

Datasheet
3VA2340-6HL32-0CC0
3VA2340-6HL32-0CC0
3VA2340-6HL32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0CH0
3VA2340-6HL32-0CH0
3VA2340-6HL32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,264.26

EACH

Datasheet
3VA2340-6HL32-0CL0
3VA2340-6HL32-0CL0
3VA2340-6HL32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,297.71

EACH

Datasheet
3VA2340-6HL32-0DA0
3VA2340-6HL32-0DA0
3VA2340-6HL32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,217.43

EACH

Datasheet
3VA2340-6HL32-0DC0
3VA2340-6HL32-0DC0
3VA2340-6HL32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0DH0
3VA2340-6HL32-0DH0
3VA2340-6HL32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,264.26

EACH

Datasheet
3VA2340-6HL32-0DL0
3VA2340-6HL32-0DL0
3VA2340-6HL32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,297.71

EACH

Datasheet
3VA2340-6HL32-0HA0
3VA2340-6HL32-0HA0
3VA2340-6HL32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,259.17

EACH

Datasheet
3VA2340-6HL32-0HC0
3VA2340-6HL32-0HC0
3VA2340-6HL32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2340-6HL32-0HH0
3VA2340-6HL32-0HH0
3VA2340-6HL32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0HL0
3VA2340-6HL32-0HL0
3VA2340-6HL32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2340-6HL32-0JA0
3VA2340-6HL32-0JA0
3VA2340-6HL32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,259.17

EACH

Datasheet
3VA2340-6HL32-0JC0
3VA2340-6HL32-0JC0
3VA2340-6HL32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2340-6HL32-0JH0
3VA2340-6HL32-0JH0
3VA2340-6HL32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0JL0
3VA2340-6HL32-0JL0
3VA2340-6HL32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2340-6HL32-0KA0
3VA2340-6HL32-0KA0
3VA2340-6HL32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,259.17

EACH

Datasheet
3VA2340-6HL32-0KC0
3VA2340-6HL32-0KC0
3VA2340-6HL32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,230.82

EACH

Datasheet
3VA2340-6HL32-0KF0
3VA2340-6HL32-0KF0
3VA2340-6HL32-0KF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,235.40

EACH

Datasheet
3VA2340-6HL32-0KH0
3VA2340-6HL32-0KH0
3VA2340-6HL32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,250.87

EACH

Datasheet
3VA2340-6HL32-0KL0
3VA2340-6HL32-0KL0
3VA2340-6HL32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,270.94

EACH

Datasheet
3VA2340-6HL32-0LB0
3VA2340-6HL32-0LB0
3VA2340-6HL32-0LB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V universal release 24V DC 2 auxiliary switches HP

£1,406.91

EACH

Datasheet
3VA2340-6HL42-0AA0
3VA2340-6HL42-0AA0
3VA2340-6HL42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,168.31

EACH

Datasheet
3VA2340-6HL42-0AJ0
3VA2340-6HL42-0AJ0
3VA2340-6HL42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,571.96

EACH

Datasheet
3VA2340-6HM32-0AA0
3VA2340-6HM32-0AA0
3VA2340-6HM32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,134.01

EACH

Datasheet
3VA2340-6HM32-0AH0
3VA2340-6HM32-0AH0
3VA2340-6HM32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,378.88

EACH

Datasheet
3VA2340-6HM42-0AA0
3VA2340-6HM42-0AA0
3VA2340-6HM42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,421.49

EACH

Datasheet
3VA2340-6HN32-0AA0
3VA2340-6HN32-0AA0
3VA2340-6HN32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£1,146.32

EACH

Datasheet
3VA2340-6HN32-0AB0
3VA2340-6HN32-0AB0
3VA2340-6HN32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£1,250.87

EACH

Datasheet
3VA2340-6HN32-0AC0
3VA2340-6HN32-0AC0
3VA2340-6HN32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£1,237.50

EACH

Datasheet
3VA2340-6HN32-0AD0
3VA2340-6HN32-0AD0
3VA2340-6HN32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£1,250.87

EACH

Datasheet
3VA2340-6HN32-0AE0
3VA2340-6HN32-0AE0
3VA2340-6HN32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£1,264.26

EACH

Datasheet
3VA2340-6HN32-0AF0
3VA2340-6HN32-0AF0
3VA2340-6HN32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,237.50

EACH

Datasheet
3VA2340-6HN32-0AG0
3VA2340-6HN32-0AG0
3VA2340-6HN32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,250.87

EACH

Datasheet
3VA2340-6HN32-0AH0
3VA2340-6HN32-0AH0
3VA2340-6HN32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,250.87

EACH

Datasheet
3VA2340-6HN32-0AJ0
3VA2340-6HN32-0AJ0
3VA2340-6HN32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,277.64

EACH

Datasheet
3VA2340-6HN32-0BA0
3VA2340-6HN32-0BA0
3VA2340-6HN32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,277.64

EACH

Datasheet
3VA2340-6HN32-0BC0
3VA2340-6HN32-0BC0
3VA2340-6HN32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0BH0
3VA2340-6HN32-0BH0
3VA2340-6HN32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2340-6HN32-0BL0
3VA2340-6HN32-0BL0
3VA2340-6HN32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-6HN32-0CA0
3VA2340-6HN32-0CA0
3VA2340-6HN32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,277.64

EACH

Datasheet
3VA2340-6HN32-0CC0
3VA2340-6HN32-0CC0
3VA2340-6HN32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0CH0
3VA2340-6HN32-0CH0
3VA2340-6HN32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2340-6HN32-0CL0
3VA2340-6HN32-0CL0
3VA2340-6HN32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-6HN32-0DA0
3VA2340-6HN32-0DA0
3VA2340-6HN32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,277.64

EACH

Datasheet
3VA2340-6HN32-0DC0
3VA2340-6HN32-0DC0
3VA2340-6HN32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0DH0
3VA2340-6HN32-0DH0
3VA2340-6HN32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,344.53

EACH

Datasheet
3VA2340-6HN32-0DL0
3VA2340-6HN32-0DL0
3VA2340-6HN32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-6HN32-0HA0
3VA2340-6HN32-0HA0
3VA2340-6HN32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,257.56

EACH

Datasheet
3VA2340-6HN32-0HC0
3VA2340-6HN32-0HC0
3VA2340-6HN32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,297.71

EACH

Datasheet
3VA2340-6HN32-0HH0
3VA2340-6HN32-0HH0
3VA2340-6HN32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0HL0
3VA2340-6HN32-0HL0
3VA2340-6HN32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,351.22

EACH

Datasheet
3VA2340-6HN32-0JA0
3VA2340-6HN32-0JA0
3VA2340-6HN32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,257.56

EACH

Datasheet
3VA2340-6HN32-0JC0
3VA2340-6HN32-0JC0
3VA2340-6HN32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,297.71

EACH

Datasheet
3VA2340-6HN32-0JH0
3VA2340-6HN32-0JH0
3VA2340-6HN32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0JL0
3VA2340-6HN32-0JL0
3VA2340-6HN32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,351.22

EACH

Datasheet
3VA2340-6HN32-0KA0
3VA2340-6HN32-0KA0
3VA2340-6HN32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,257.56

EACH

Datasheet
3VA2340-6HN32-0KC0
3VA2340-6HN32-0KC0
3VA2340-6HN32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,297.71

EACH

Datasheet
3VA2340-6HN32-0KH0
3VA2340-6HN32-0KH0
3VA2340-6HN32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,324.46

EACH

Datasheet
3VA2340-6HN32-0KL0
3VA2340-6HN32-0KL0
3VA2340-6HN32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,351.22

EACH

Datasheet
3VA2340-6HN42-0AA0
3VA2340-6HN42-0AA0
3VA2340-6HN42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,280.12

EACH

Datasheet
3VA2340-6HN42-0KA0
3VA2340-6HN42-0KA0
3VA2340-6HN42-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY

£1,632.03

EACH

Datasheet
3VA2340-6HN42-0KF0
3VA2340-6HN42-0KF0
3VA2340-6HN42-0KF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,658.92

EACH

Datasheet
3VA2340-6JP32-0AA0
3VA2340-6JP32-0AA0
3VA2340-6JP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,587.65

EACH

Datasheet
3VA2340-6JP32-0AB0
3VA2340-6JP32-0AB0
3VA2340-6JP32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP

£1,565.27

EACH

Datasheet
3VA2340-6JP32-0AC0
3VA2340-6JP32-0AC0
3VA2340-6JP32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ

£1,551.89

EACH

Datasheet
3VA2340-6JP32-0AD0
3VA2340-6JP32-0AD0
3VA2340-6JP32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 3 auxiliary switches HQ

£1,565.27

EACH

Datasheet
3VA2340-6JP32-0AE0
3VA2340-6JP32-0AE0
3VA2340-6JP32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 4 auxiliary switches HQ

£1,578.65

EACH

Datasheet
3VA2340-6JP32-0AF0
3VA2340-6JP32-0AF0
3VA2340-6JP32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,551.89

EACH

Datasheet
3VA2340-6JP32-0AG0
3VA2340-6JP32-0AG0
3VA2340-6JP32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,565.27

EACH

Datasheet
3VA2340-6JP32-0AH0
3VA2340-6JP32-0AH0
3VA2340-6JP32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,565.27

EACH

Datasheet
3VA2340-6JP32-0AJ0
3VA2340-6JP32-0AJ0
3VA2340-6JP32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,592.04

EACH

Datasheet
3VA2340-6JP32-0BA0
3VA2340-6JP32-0BA0
3VA2340-6JP32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC

£1,592.04

EACH

Datasheet
3VA2340-6JP32-0BC0
3VA2340-6JP32-0BC0
3VA2340-6JP32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0BH0
3VA2340-6JP32-0BH0
3VA2340-6JP32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,645.54

EACH

Datasheet
3VA2340-6JP32-0BL0
3VA2340-6JP32-0BL0
3VA2340-6JP32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-6JP32-0CA0
3VA2340-6JP32-0CA0
3VA2340-6JP32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,592.04

EACH

Datasheet
3VA2340-6JP32-0CC0
3VA2340-6JP32-0CC0
3VA2340-6JP32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0CH0
3VA2340-6JP32-0CH0
3VA2340-6JP32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,645.54

EACH

Datasheet
3VA2340-6JP32-0CL0
3VA2340-6JP32-0CL0
3VA2340-6JP32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-6JP32-0DA0
3VA2340-6JP32-0DA0
3VA2340-6JP32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,592.04

EACH

Datasheet
3VA2340-6JP32-0DC0
3VA2340-6JP32-0DC0
3VA2340-6JP32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0DD0
3VA2340-6JP32-0DD0
3VA2340-6JP32-0DD0Circuit breaker 3VA2 IEC Frame 400 Switching capacity class H Icu=85 kA @ 415 V 3-pole, system protection ETU550, LSI, In=400 A Overload protection Ir=160 A...400 A Short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N-conductor protection Optionally with external current transformer, up to 160% Lug terminal Circuit breaker 3VA2 IEC Undervoltage release 208-230 V AC 50/60 Hz 3 auxiliary switches HQ

£1,652.24

EACH

Datasheet
3VA2340-6JP32-0DH0
3VA2340-6JP32-0DH0
3VA2340-6JP32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,645.54

EACH

Datasheet
3VA2340-6JP32-0DL0
3VA2340-6JP32-0DL0
3VA2340-6JP32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,672.31

EACH

Datasheet
3VA2340-6JP32-0HA0
3VA2340-6JP32-0HA0
3VA2340-6JP32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,571.96

EACH

Datasheet
3VA2340-6JP32-0HC0
3VA2340-6JP32-0HC0
3VA2340-6JP32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,605.41

EACH

Datasheet
3VA2340-6JP32-0HH0
3VA2340-6JP32-0HH0
3VA2340-6JP32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0HL0
3VA2340-6JP32-0HL0
3VA2340-6JP32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,652.24

EACH

Datasheet
3VA2340-6JP32-0JA0
3VA2340-6JP32-0JA0
3VA2340-6JP32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,571.96

EACH

Datasheet
3VA2340-6JP32-0JC0
3VA2340-6JP32-0JC0
3VA2340-6JP32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,605.41

EACH

Datasheet
3VA2340-6JP32-0JH0
3VA2340-6JP32-0JH0
3VA2340-6JP32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0JL0
3VA2340-6JP32-0JL0
3VA2340-6JP32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,652.24

EACH

Datasheet
3VA2340-6JP32-0KA0
3VA2340-6JP32-0KA0
3VA2340-6JP32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,571.96

EACH

Datasheet
3VA2340-6JP32-0KC0
3VA2340-6JP32-0KC0
3VA2340-6JP32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,605.41

EACH

Datasheet
3VA2340-6JP32-0KH0
3VA2340-6JP32-0KH0
3VA2340-6JP32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,632.16

EACH

Datasheet
3VA2340-6JP32-0KL0
3VA2340-6JP32-0KL0
3VA2340-6JP32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,652.24

EACH

Datasheet
3VA2340-6JP42-0AA0
3VA2340-6JP42-0AA0
3VA2340-6JP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,907.42

EACH

Datasheet
3VA2340-6JP42-0AJ0
3VA2340-6JP42-0AJ0
3VA2340-6JP42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,946.56

EACH

Datasheet
3VA2340-6JP42-0BC0
3VA2340-6JP42-0BC0
3VA2340-6JP42-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H

£1,983.14

EACH

Datasheet
3VA2340-6JP42-0KE0
3VA2340-6JP42-0KE0
3VA2340-6JP42-0KE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 4 AUXILIARY SWITCH CHANGEOVER H

£2,000.08

EACH

Datasheet
3VA2340-6JQ32-0AA0
3VA2340-6JQ32-0AA0
3VA2340-6JQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,276.40

EACH

Datasheet
3VA2340-6JQ32-0AB0
3VA2340-6JQ32-0AB0
3VA2340-6JQ32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP

£1,759.26

EACH

Datasheet
3VA2340-6JQ32-0AC0
3VA2340-6JQ32-0AC0
3VA2340-6JQ32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ

£1,745.88

EACH

Datasheet
3VA2340-6JQ32-0AD0
3VA2340-6JQ32-0AD0
3VA2340-6JQ32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ

£1,759.26

EACH

Datasheet
3VA2340-6JQ32-0AE0
3VA2340-6JQ32-0AE0
3VA2340-6JQ32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 4 auxiliary switches HQ

£1,772.65

EACH

Datasheet
3VA2340-6JQ32-0AF0
3VA2340-6JQ32-0AF0
3VA2340-6JQ32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,745.88

EACH

Datasheet
3VA2340-6JQ32-0AG0
3VA2340-6JQ32-0AG0
3VA2340-6JQ32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,759.26

EACH

Datasheet
3VA2340-6JQ32-0AH0
3VA2340-6JQ32-0AH0
3VA2340-6JQ32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,759.26

EACH

Datasheet
3VA2340-6JQ32-0AJ0
3VA2340-6JQ32-0AJ0
3VA2340-6JQ32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,786.03

EACH

Datasheet
3VA2340-6JQ32-0BA0
3VA2340-6JQ32-0BA0
3VA2340-6JQ32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC

£1,786.03

EACH

Datasheet
3VA2340-6JQ32-0BC0
3VA2340-6JQ32-0BC0
3VA2340-6JQ32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0BH0
3VA2340-6JQ32-0BH0
3VA2340-6JQ32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,832.85

EACH

Datasheet
3VA2340-6JQ32-0BL0
3VA2340-6JQ32-0BL0
3VA2340-6JQ32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, IN=400A overload protection Ir=160A ...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,859.59

EACH

Datasheet
3VA2340-6JQ32-0CA0
3VA2340-6JQ32-0CA0
3VA2340-6JQ32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,786.03

EACH

Datasheet
3VA2340-6JQ32-0CC0
3VA2340-6JQ32-0CC0
3VA2340-6JQ32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0CH0
3VA2340-6JQ32-0CH0
3VA2340-6JQ32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,832.85

EACH

Datasheet
3VA2340-6JQ32-0CL0
3VA2340-6JQ32-0CL0
3VA2340-6JQ32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,859.59

EACH

Datasheet
3VA2340-6JQ32-0DA0
3VA2340-6JQ32-0DA0
3VA2340-6JQ32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,786.03

EACH

Datasheet
3VA2340-6JQ32-0DC0
3VA2340-6JQ32-0DC0
3VA2340-6JQ32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0DH0
3VA2340-6JQ32-0DH0
3VA2340-6JQ32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,832.85

EACH

Datasheet
3VA2340-6JQ32-0DL0
3VA2340-6JQ32-0DL0
3VA2340-6JQ32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, IN=400A overload protection Ir=160A ...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,859.59

EACH

Datasheet
3VA2340-6JQ32-0HA0
3VA2340-6JQ32-0HA0
3VA2340-6JQ32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,765.95

EACH

Datasheet
3VA2340-6JQ32-0HC0
3VA2340-6JQ32-0HC0
3VA2340-6JQ32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,799.39

EACH

Datasheet
3VA2340-6JQ32-0HH0
3VA2340-6JQ32-0HH0
3VA2340-6JQ32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0HL0
3VA2340-6JQ32-0HL0
3VA2340-6JQ32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,839.52

EACH

Datasheet
3VA2340-6JQ32-0JA0
3VA2340-6JQ32-0JA0
3VA2340-6JQ32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,765.95

EACH

Datasheet
3VA2340-6JQ32-0JC0
3VA2340-6JQ32-0JC0
3VA2340-6JQ32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,799.39

EACH

Datasheet
3VA2340-6JQ32-0JH0
3VA2340-6JQ32-0JH0
3VA2340-6JQ32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0JL0
3VA2340-6JQ32-0JL0
3VA2340-6JQ32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,839.52

EACH

Datasheet
3VA2340-6JQ32-0KA0
3VA2340-6JQ32-0KA0
3VA2340-6JQ32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,765.95

EACH

Datasheet
3VA2340-6JQ32-0KC0
3VA2340-6JQ32-0KC0
3VA2340-6JQ32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,799.39

EACH

Datasheet
3VA2340-6JQ32-0KH0
3VA2340-6JQ32-0KH0
3VA2340-6JQ32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,819.47

EACH

Datasheet
3VA2340-6JQ32-0KL0
3VA2340-6JQ32-0KL0
3VA2340-6JQ32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection, opt. w. ext. curr. transf., up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,839.52

EACH

Datasheet
3VA2340-6JQ42-0AA0
3VA2340-6JQ42-0AA0
3VA2340-6JQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,105.23

EACH

Datasheet
3VA2340-6JQ42-0DJ0
3VA2340-6JQ42-0DJ0
3VA2340-6JQ42-0DJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release 208-230V AC 50/60Hz 2 auxiliary switches 1 trip alarm switch

£2,227.51

EACH

Datasheet
3VA2340-6KP32-0AA0
3VA2340-6KP32-0AA0
3VA2340-6KP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,450.69

EACH

Datasheet
3VA2340-6KP32-0AB0
3VA2340-6KP32-0AB0
3VA2340-6KP32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP

£1,725.82

EACH

Datasheet
3VA2340-6KP32-0AC0
3VA2340-6KP32-0AC0
3VA2340-6KP32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ

£1,712.44

EACH

Datasheet
3VA2340-6KP32-0AD0
3VA2340-6KP32-0AD0
3VA2340-6KP32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 3 auxiliary switches HQ

£1,725.82

EACH

Datasheet
3VA2340-6KP32-0AE0
3VA2340-6KP32-0AE0
3VA2340-6KP32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 4 auxiliary switches HQ

£1,745.88

EACH

Datasheet
3VA2340-6KP32-0AF0
3VA2340-6KP32-0AF0
3VA2340-6KP32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,712.44

EACH

Datasheet
3VA2340-6KP32-0AG0
3VA2340-6KP32-0AG0
3VA2340-6KP32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,725.82

EACH

Datasheet
3VA2340-6KP32-0AH0
3VA2340-6KP32-0AH0
3VA2340-6KP32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,725.82

EACH

Datasheet
3VA2340-6KP32-0AJ0
3VA2340-6KP32-0AJ0
3VA2340-6KP32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,759.26

EACH

Datasheet
3VA2340-6KP32-0BA0
3VA2340-6KP32-0BA0
3VA2340-6KP32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC

£1,759.26

EACH

Datasheet
3VA2340-6KP32-0BC0
3VA2340-6KP32-0BC0
3VA2340-6KP32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0BH0
3VA2340-6KP32-0BH0
3VA2340-6KP32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,806.08

EACH

Datasheet
3VA2340-6KP32-0BL0
3VA2340-6KP32-0BL0
3VA2340-6KP32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,832.85

EACH

Datasheet
3VA2340-6KP32-0CA0
3VA2340-6KP32-0CA0
3VA2340-6KP32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,759.26

EACH

Datasheet
3VA2340-6KP32-0CC0
3VA2340-6KP32-0CC0
3VA2340-6KP32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0CH0
3VA2340-6KP32-0CH0
3VA2340-6KP32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,806.08

EACH

Datasheet
3VA2340-6KP32-0CL0
3VA2340-6KP32-0CL0
3VA2340-6KP32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,832.85

EACH

Datasheet
3VA2340-6KP32-0DA0
3VA2340-6KP32-0DA0
3VA2340-6KP32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,759.26

EACH

Datasheet
3VA2340-6KP32-0DC0
3VA2340-6KP32-0DC0
3VA2340-6KP32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0DH0
3VA2340-6KP32-0DH0
3VA2340-6KP32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,806.08

EACH

Datasheet
3VA2340-6KP32-0DL0
3VA2340-6KP32-0DL0
3VA2340-6KP32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,832.85

EACH

Datasheet
3VA2340-6KP32-0HA0
3VA2340-6KP32-0HA0
3VA2340-6KP32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz

£1,732.51

EACH

Datasheet
3VA2340-6KP32-0HC0
3VA2340-6KP32-0HC0
3VA2340-6KP32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ

£1,772.65

EACH

Datasheet
3VA2340-6KP32-0HH0
3VA2340-6KP32-0HH0
3VA2340-6KP32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0HL0
3VA2340-6KP32-0HL0
3VA2340-6KP32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,812.77

EACH

Datasheet
3VA2340-6KP32-0JA0
3VA2340-6KP32-0JA0
3VA2340-6KP32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,732.51

EACH

Datasheet
3VA2340-6KP32-0JC0
3VA2340-6KP32-0JC0
3VA2340-6KP32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,772.65

EACH

Datasheet
3VA2340-6KP32-0JH0
3VA2340-6KP32-0JH0
3VA2340-6KP32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0JL0
3VA2340-6KP32-0JL0
3VA2340-6KP32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,812.77

EACH

Datasheet
3VA2340-6KP32-0KA0
3VA2340-6KP32-0KA0
3VA2340-6KP32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£1,732.51

EACH

Datasheet
3VA2340-6KP32-0KC0
3VA2340-6KP32-0KC0
3VA2340-6KP32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£1,772.65

EACH

Datasheet
3VA2340-6KP32-0KH0
3VA2340-6KP32-0KH0
3VA2340-6KP32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,792.70

EACH

Datasheet
3VA2340-6KP32-0KL0
3VA2340-6KP32-0KL0
3VA2340-6KP32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6...10 x In, Ii=1.5 x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,812.77

EACH

Datasheet
3VA2340-6KP42-0AA0
3VA2340-6KP42-0AA0
3VA2340-6KP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£1,929.34

EACH

Datasheet
3VA2340-6KP42-0AJ0
3VA2340-6KP42-0AJ0
3VA2340-6KP42-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£2,107.10

EACH

Datasheet
3VA2340-6KQ32-0AA0
3VA2340-6KQ32-0AA0
3VA2340-6KQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,375.62

EACH

Datasheet
3VA2340-6KQ32-0KC0
3VA2340-6KQ32-0KC0
3VA2340-6KQ32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class H SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 2 AUXILIARY SWITCH CHANGEOVER H

£1,879.10

EACH

Datasheet
3VA2340-6KQ42-0AA0
3VA2340-6KQ42-0AA0
3VA2340-6KQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,028.13

EACH

Datasheet
3VA2340-7HL32-0AA0
3VA2340-7HL32-0AA0
3VA2340-7HL32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit

£1,084.07

EACH

Datasheet
3VA2340-7HL32-0AB0
3VA2340-7HL32-0AB0
3VA2340-7HL32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP

£1,270.94

EACH

Datasheet
3VA2340-7HL32-0AC0
3VA2340-7HL32-0AC0
3VA2340-7HL32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ

£1,257.56

EACH

Datasheet
3VA2340-7HL32-0AD0
3VA2340-7HL32-0AD0
3VA2340-7HL32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 3 auxiliary switches HQ

£1,270.94

EACH

Datasheet
3VA2340-7HL32-0AE0
3VA2340-7HL32-0AE0
3VA2340-7HL32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 4 auxiliary switches HQ

£1,291.02

EACH

Datasheet
3VA2340-7HL32-0AF0
3VA2340-7HL32-0AF0
3VA2340-7HL32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,257.56

EACH

Datasheet
3VA2340-7HL32-0AG0
3VA2340-7HL32-0AG0
3VA2340-7HL32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,270.94

EACH

Datasheet
3VA2340-7HL32-0AH0
3VA2340-7HL32-0AH0
3VA2340-7HL32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,270.94

EACH

Datasheet
3VA2340-7HL32-0AJ0
3VA2340-7HL32-0AJ0
3VA2340-7HL32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,304.39

EACH

Datasheet
3VA2340-7HL32-0AL0
3VA2340-7HL32-0AL0
3VA2340-7HL32-0AL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut 2 auxiliary switch changeover H 1 trip alarm switch changeover 1 electrical alarm switch HQ

£1,304.39

EACH

Datasheet
3VA2340-7HL32-0BA0
3VA2340-7HL32-0BA0
3VA2340-7HL32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,304.39

EACH

Datasheet
3VA2340-7HL32-0BC0
3VA2340-7HL32-0BC0
3VA2340-7HL32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0BH0
3VA2340-7HL32-0BH0
3VA2340-7HL32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,364.61

EACH

Datasheet
3VA2340-7HL32-0BL0
3VA2340-7HL32-0BL0
3VA2340-7HL32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,391.36

EACH

Datasheet
3VA2340-7HL32-0CA0
3VA2340-7HL32-0CA0
3VA2340-7HL32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,304.39

EACH

Datasheet
3VA2340-7HL32-0CC0
3VA2340-7HL32-0CC0
3VA2340-7HL32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0CH0
3VA2340-7HL32-0CH0
3VA2340-7HL32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,364.61

EACH

Datasheet
3VA2340-7HL32-0CL0
3VA2340-7HL32-0CL0
3VA2340-7HL32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,391.36

EACH

Datasheet
3VA2340-7HL32-0DA0
3VA2340-7HL32-0DA0
3VA2340-7HL32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,304.39

EACH

Datasheet
3VA2340-7HL32-0DC0
3VA2340-7HL32-0DC0
3VA2340-7HL32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0DH0
3VA2340-7HL32-0DH0
3VA2340-7HL32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,364.61

EACH

Datasheet
3VA2340-7HL32-0DL0
3VA2340-7HL32-0DL0
3VA2340-7HL32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,391.36

EACH

Datasheet
3VA2340-7HL32-0HA0
3VA2340-7HL32-0HA0
3VA2340-7HL32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,277.64

EACH

Datasheet
3VA2340-7HL32-0HC0
3VA2340-7HL32-0HC0
3VA2340-7HL32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-7HL32-0HH0
3VA2340-7HL32-0HH0
3VA2340-7HL32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0HL0
3VA2340-7HL32-0HL0
3VA2340-7HL32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-7HL32-0JA0
3VA2340-7HL32-0JA0
3VA2340-7HL32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,277.64

EACH

Datasheet
3VA2340-7HL32-0JC0
3VA2340-7HL32-0JC0
3VA2340-7HL32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-7HL32-0JH0
3VA2340-7HL32-0JH0
3VA2340-7HL32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0JL0
3VA2340-7HL32-0JL0
3VA2340-7HL32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-7HL32-0KA0
3VA2340-7HL32-0KA0
3VA2340-7HL32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,277.64

EACH

Datasheet
3VA2340-7HL32-0KC0
3VA2340-7HL32-0KC0
3VA2340-7HL32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,324.46

EACH

Datasheet
3VA2340-7HL32-0KH0
3VA2340-7HL32-0KH0
3VA2340-7HL32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,351.22

EACH

Datasheet
3VA2340-7HL32-0KL0
3VA2340-7HL32-0KL0
3VA2340-7HL32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,371.29

EACH

Datasheet
3VA2340-7HL42-0AA0
3VA2340-7HL42-0AA0
3VA2340-7HL42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,420.80

EACH

Datasheet
3VA2340-7HL42-0HB0
3VA2340-7HL42-0HB0
3VA2340-7HL42-0HB0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit shunt trip (STL) 12-30V DC; 24V AC 50/60Hz 2 auxiliary switches HP

£1,719.13

EACH

Datasheet
3VA2340-7HM32-0AA0
3VA2340-7HM32-0AA0
3VA2340-7HM32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,328.10

EACH

Datasheet
3VA2340-7HM42-0AA0
3VA2340-7HM42-0AA0
3VA2340-7HM42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£1,664.81

EACH

Datasheet
3VA2340-7HN32-0AA0
3VA2340-7HN32-0AA0
3VA2340-7HN32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£1,356.43

EACH

Datasheet
3VA2340-7HN32-0AB0
3VA2340-7HN32-0AB0
3VA2340-7HN32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP

£1,351.22

EACH

Datasheet
3VA2340-7HN32-0AC0
3VA2340-7HN32-0AC0
3VA2340-7HN32-0AC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£1,406.91

EACH

Datasheet
3VA2340-7HN32-0AD0
3VA2340-7HN32-0AD0
3VA2340-7HN32-0AD0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£1,351.22

EACH

Datasheet
3VA2340-7HN32-0AE0
3VA2340-7HN32-0AE0
3VA2340-7HN32-0AE0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£1,364.61

EACH

Datasheet
3VA2340-7HN32-0AF0
3VA2340-7HN32-0AF0
3VA2340-7HN32-0AF0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,406.91

EACH

Datasheet
3VA2340-7HN32-0AG0
3VA2340-7HN32-0AG0
3VA2340-7HN32-0AG0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,351.22

EACH

Datasheet
3VA2340-7HN32-0AH0
3VA2340-7HN32-0AH0
3VA2340-7HN32-0AH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,351.22

EACH

Datasheet
3VA2340-7HN32-0AJ0
3VA2340-7HN32-0AJ0
3VA2340-7HN32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,377.98

EACH

Datasheet
3VA2340-7HN32-0BA0
3VA2340-7HN32-0BA0
3VA2340-7HN32-0BA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,377.98

EACH

Datasheet
3VA2340-7HN32-0BC0
3VA2340-7HN32-0BC0
3VA2340-7HN32-0BC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0BH0
3VA2340-7HN32-0BH0
3VA2340-7HN32-0BH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-7HN32-0BL0
3VA2340-7HN32-0BL0
3VA2340-7HN32-0BL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,458.25

EACH

Datasheet
3VA2340-7HN32-0CA0
3VA2340-7HN32-0CA0
3VA2340-7HN32-0CA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,377.98

EACH

Datasheet
3VA2340-7HN32-0CC0
3VA2340-7HN32-0CC0
3VA2340-7HN32-0CC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0CH0
3VA2340-7HN32-0CH0
3VA2340-7HN32-0CH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-7HN32-0CL0
3VA2340-7HN32-0CL0
3VA2340-7HN32-0CL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,458.25

EACH

Datasheet
3VA2340-7HN32-0DA0
3VA2340-7HN32-0DA0
3VA2340-7HN32-0DA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,377.98

EACH

Datasheet
3VA2340-7HN32-0DC0
3VA2340-7HN32-0DC0
3VA2340-7HN32-0DC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0DH0
3VA2340-7HN32-0DH0
3VA2340-7HN32-0DH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,424.81

EACH

Datasheet
3VA2340-7HN32-0DL0
3VA2340-7HN32-0DL0
3VA2340-7HN32-0DL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,458.25

EACH

Datasheet
3VA2340-7HN32-0HA0
3VA2340-7HN32-0HA0
3VA2340-7HN32-0HA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,357.91

EACH

Datasheet
3VA2340-7HN32-0HC0
3VA2340-7HN32-0HC0
3VA2340-7HN32-0HC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2340-7HN32-0HH0
3VA2340-7HN32-0HH0
3VA2340-7HN32-0HH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0HL0
3VA2340-7HN32-0HL0
3VA2340-7HN32-0HL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2340-7HN32-0JA0
3VA2340-7HN32-0JA0
3VA2340-7HN32-0JA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,357.91

EACH

Datasheet
3VA2340-7HN32-0JC0
3VA2340-7HN32-0JC0
3VA2340-7HN32-0JC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2340-7HN32-0JH0
3VA2340-7HN32-0JH0
3VA2340-7HN32-0JH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0JL0
3VA2340-7HN32-0JL0
3VA2340-7HN32-0JL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2340-7HN32-0KA0
3VA2340-7HN32-0KA0
3VA2340-7HN32-0KA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,357.91

EACH

Datasheet
3VA2340-7HN32-0KC0
3VA2340-7HN32-0KC0
3VA2340-7HN32-0KC0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,391.36

EACH

Datasheet
3VA2340-7HN32-0KH0
3VA2340-7HN32-0KH0
3VA2340-7HN32-0KH0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,411.43

EACH

Datasheet
3VA2340-7HN32-0KL0
3VA2340-7HN32-0KL0
3VA2340-7HN32-0KL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,438.18

EACH

Datasheet
3VA2340-7HN42-0AA0
3VA2340-7HN42-0AA0
3VA2340-7HN42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,499.22

EACH

Datasheet
3VA2340-7JP32-0AA0
3VA2340-7JP32-0AA0
3VA2340-7JP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,680.11

EACH

Datasheet
3VA2340-7JP42-0AA0
3VA2340-7JP42-0AA0
3VA2340-7JP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,096.27

EACH

Datasheet
3VA2340-7JQ32-0AA0
3VA2340-7JQ32-0AA0
3VA2340-7JQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,880.49

EACH

Datasheet
3VA2340-7JQ42-0AA0
3VA2340-7JQ42-0AA0
3VA2340-7JQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,131.81

EACH

Datasheet
3VA2340-7KP32-0AA0
3VA2340-7KP32-0AA0
3VA2340-7KP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,675.94

EACH

Datasheet
3VA2340-7KP32-0AB0
3VA2340-7KP32-0AB0
3VA2340-7KP32-0AB0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=400A 2 AUXILIARY SWITCH CHANGEOVER H

£1,820.58

EACH

Datasheet
3VA2340-7KP32-0AL0
3VA2340-7KP32-0AL0
3VA2340-7KP32-0AL0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=400A 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,848.69

EACH

Datasheet
3VA2340-7KP42-0AA0
3VA2340-7KP42-0AA0
3VA2340-7KP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,217.62

EACH

Datasheet
3VA2340-7KQ32-0AA0
3VA2340-7KQ32-0AA0
3VA2340-7KQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,957.57

EACH

Datasheet
3VA2340-7KQ42-0AA0
3VA2340-7KQ42-0AA0
3VA2340-7KQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,373.73

EACH

Datasheet
3VA2340-8HL32-0AA0
3VA2340-8HL32-0AA0
3VA2340-8HL32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit

£1,397.95

EACH

Datasheet
3VA2340-8HL32-0AJ0
3VA2340-8HL32-0AJ0
3VA2340-8HL32-0AJ0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut keeper kit circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In nut 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,475.99

EACH

Datasheet
3VA2340-8HL42-0AA0
3VA2340-8HL42-0AA0
3VA2340-8HL42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,846.59

EACH

Datasheet
3VA2340-8HM32-0AA0
3VA2340-8HM32-0AA0
3VA2340-8HM32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit

£1,586.51

EACH

Datasheet
3VA2340-8HM42-0AA0
3VA2340-8HM42-0AA0
3VA2340-8HM42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU330, LIG, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit

£2,041.67

EACH

Datasheet
3VA2340-8HN32-0AA0
3VA2340-8HN32-0AA0
3VA2340-8HN32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit

£1,469.48

EACH

Datasheet
3VA2340-8HN42-0AA0
3VA2340-8HN42-0AA0
3VA2340-8HN42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU350, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,918.12

EACH

Datasheet
3VA2340-8JP32-0AA0
3VA2340-8JP32-0AA0
3VA2340-8JP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,788.07

EACH

Datasheet
3VA2340-8JP42-0AA0
3VA2340-8JP42-0AA0
3VA2340-8JP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU550, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,243.23

EACH

Datasheet
3VA2340-8JQ32-0AA0
3VA2340-8JQ32-0AA0
3VA2340-8JQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£1,983.14

EACH

Datasheet
3VA2340-8JQ42-0AA0
3VA2340-8JQ42-0AA0
3VA2340-8JQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,412.27

EACH

Datasheet
3VA2340-8KP32-0AA0
3VA2340-8KP32-0AA0
3VA2340-8KP32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,931.13

EACH

Datasheet
3VA2340-8KP42-0AA0
3VA2340-8KP42-0AA0
3VA2340-8KP42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU850, LSI, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,386.26

EACH

Datasheet
3VA2340-8KQ32-0AA0
3VA2340-8KQ32-0AA0
3VA2340-8KQ32-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,048.16

EACH

Datasheet
3VA2340-8KQ42-0AA0
3VA2340-8KQ42-0AA0
3VA2340-8KQ42-0AA0circuit breaker 3VA2 IEC frame 400 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU860, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,503.32

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM