Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3WL11 - Frame Size 11600 A
3WL1116-2AA31-1AA2-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S05= Fortress locking device in OFF position (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2 S33= Locking device Tension lever T40= Door sealing frame

£4,938.52

EACH

Datasheet
3WL1116-2AA32-1AA2
3WL1116-2AA32-1AA2
3WL1116-2AA32-1AA2fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£4,320.25

EACH

Datasheet
3WL1116-2AA33-4AN4-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC T40= Door sealing frame

£6,138.94

EACH

Datasheet
3WL1116-2DG46-5FA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£11,681.35

EACH

Datasheet
3WL1116-2DG47-1AA2
3WL1116-2DG47-1AA2
3WL1116-2DG47-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,578.03

EACH

Datasheet
3WL1116-2DG47-1AA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£10,537.75

EACH

Datasheet
3WL1116-2DG47-1FM2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£11,746.42

EACH

Datasheet
3WL1116-2DG47-1FN2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£11,930.12

EACH

Datasheet
3WL1116-2DG47-3BB2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 230 V AC, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 2NO+2NC S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£10,236.21

EACH

Datasheet
3WL1116-2DG47-4GN4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£12,566.13

EACH

Datasheet
3WL1116-2EB32-4GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£6,986.51

EACH

Datasheet
3WL1116-2EB33-1AA2
3WL1116-2EB33-1AA2
3WL1116-2EB33-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,846.92

EACH

Datasheet
3WL1116-2EB34-1AA2
3WL1116-2EB34-1AA2
3WL1116-2EB34-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,846.92

EACH

Datasheet
3WL1116-2EB36-1GA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC S07= Locking device in OFF position w. 4 bracket locks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£7,422.97

EACH

Datasheet
3WL1116-2EB41-1AA4-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 S30 = LOCKING DEVICE AGAINST OP. T40= Door sealing frame

£8,093.81

EACH

Datasheet
3WL1116-2EB45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI T40= Door sealing frame

£8,526.47

EACH

Datasheet
3WL1116-2EB45-1BA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling F02= COM15 PROFIBUS module with breaker status sensor M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor T40= Door sealing frame

£10,695.04

EACH

Datasheet
3WL1116-2EB45-4BA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI T40= Door sealing frame

£9,736.40

EACH

Datasheet
3WL1116-2EB46-1AA2
3WL1116-2EB46-1AA2
3WL1116-2EB46-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,026.93

EACH

Datasheet
3WL1116-2EB46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC A08= Tin plating of customer terminals in slide-in unit frame for horizontal connection or flange connection F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,689.53

EACH

Datasheet
3WL1116-2EB46-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£11,291.57

EACH

Datasheet
3WL1116-2EB46-4BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£11,047.69

EACH

Datasheet
3WL1116-2EB46-4GA8
3WL1116-2EB46-4GA8
3WL1116-2EB46-4GA8withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 5NO+3NC

£10,425.62

EACH

Datasheet
3WL1116-2EB48-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F12= COM16 Modbus module with breaker status sensor R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,350.87

EACH

Datasheet
3WL1116-2EB72-1AA2-ZFixed-mounted circuit breaker 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B12= Rated current reference module 1250 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F23= Internal current transformers 4-pole switch BGI F35= COM35 module, PROFINET IO - Modbus TCP, with breaker status sensor F36= Metering PLUS Voltage-tap bottom side I, U, P,W, Q, f, cos phi, harmonics, THD, S07= Castell/Fortress in Off position with 4 padlocks S30 = LOCKING DEVICE AGAINST OP. S33= Castell/Fortress Tension lever T40= Door sealing frame

£9,628.09

EACH

Datasheet
3WL1116-2EG32-1FA4-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motorized operating mechanism Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor

£7,701.71

EACH

Datasheet
3WL1116-2EG36-1AA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02

£7,858.48

EACH

Datasheet
3WL1116-2EG36-4BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready indicator F02= COM15 PROFIBUS module with breaker status sensor R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£10,410.42

EACH

Datasheet
3WL1116-2EG42-1GA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£8,183.77

EACH

Datasheet
3WL1116-2EG45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI T40= Door sealing frame

£9,140.94

EACH

Datasheet
3WL1116-2EG45-1BA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling F02= COM15 PROFIBUS module with breaker status sensor F23= Internal current transformers 4-pole switch BGI M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor T40= Door sealing frame

£11,412.76

EACH

Datasheet
3WL1116-2EG45-1CA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI F40= Sealing disc for ETU25-76 for protection against unauthorized operation K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor T40= Door sealing frame

£10,625.18

EACH

Datasheet
3WL1116-2EG46-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£11,590.56

EACH

Datasheet
3WL1116-2EG47-1CA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,713.85

EACH

Datasheet
3WL1116-2EG47-6BB4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 4NO+4NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,888.93

EACH

Datasheet
3WL1116-2DG46-4GN4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC C22= Ready-to-close signaling C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 C27= Auxiliary switching function 2 Auxiliary release not possible with option F02 K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£12,109.14

EACH

Datasheet
3WL1116-2DG46-4BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,238.35

EACH

Datasheet
3WL1116-2DG46-4AN4
3WL1116-2DG46-4AN4
3WL1116-2DG46-4AN4withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC

£10,757.56

EACH

Datasheet
3WL1116-2DG46-1FA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 F23= Internal current transformers 4-pole switch BGI F40= Sealing disc for ETU25-76 for protection against unauthorized operation M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock S33= Castell/Fortress Tension lever T40= Door sealing frame

£11,584.23

EACH

Datasheet
3WL1116-2DG46-1BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£12,047.94

EACH

Datasheet
3WL1116-2DG46-1AA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£9,937.20

EACH

Datasheet
3WL1116-2DG46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock

£9,745.27

EACH

Datasheet
3WL1116-2DG45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£8,720.95

EACH

Datasheet
3WL1116-2DG42-1AA2
3WL1116-2DG42-1AA2
3WL1116-2DG42-1AA2fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,525.60

EACH

Datasheet
3WL1116-2DG36-1BA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R15= Position signaling switch, withdrawable part 3 changeover contacts

£7,810.66

EACH

Datasheet
3WL1116-2DG32-1GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£6,258.03

EACH

Datasheet
3WL1116-2DG32-1AM2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC F40= Sealing disc for ETU25-76 for protection against unauthorized operation S33= Locking device Tension lever T40= Door sealing frame

£6,452.32

EACH

Datasheet
3WL1116-2CB62-5AM2-ZFixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC T40= Door sealing frame

£6,786.35

EACH

Datasheet
3WL1116-2CB61-4AN2-ZFixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear vertical connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC C01= mechanical switching cycle counter C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 K13= Remote reset solenoid 220-240 V DC/250 V DC T40= Door sealing frame

£7,689.67

EACH

Datasheet
3WL1116-2CB48-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC

£9,641.39

EACH

Datasheet
3WL1116-2CB47-1AA4
3WL1116-2CB47-1AA4
3WL1116-2CB47-1AA4withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£9,234.70

EACH

Datasheet
3WL1116-2CB46-4GN2
3WL1116-2CB46-4GN2
3WL1116-2CB46-4GN2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£10,220.38

EACH

Datasheet
3WL1116-2CB46-4BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,813.29

EACH

Datasheet
3WL1116-2CB46-4AN2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£10,787.97

EACH

Datasheet
3WL1116-2CB46-3FG2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 230 V AC, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V

£9,624.92

EACH

Datasheet
3WL1116-2CB46-1AA8-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 5NO+3NC P01= Retrofitted to double hole connection on the front R21= Shutter 2-part can be locked with bracket lock

£9,558.40

EACH

Datasheet
3WL1116-2CB46-1AA2
3WL1116-2CB46-1AA2
3WL1116-2CB46-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£8,792.53

EACH

Datasheet
3WL1116-2CB45-6BJ2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC R57= Mutual mechanical interlock only slide-in circuit breaker 2 m

£9,337.32

EACH

Datasheet
3WL1116-2CB45-5AR4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 110-127 V AC, 110-125 V DC, 100% ED 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£9,953.24

EACH

Datasheet
3WL1116-2CB45-4GA2
3WL1116-2CB45-4GA2
3WL1116-2CB45-4GA2withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£9,052.25

EACH

Datasheet
3WL1116-2CB45-4BJ2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£9,491.25

EACH

Datasheet
3WL1116-2CB45-4BA2
3WL1116-2CB45-4BA2
3WL1116-2CB45-4BA2withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC

£9,052.25

EACH

Datasheet
3WL1116-2CB45-4AA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£9,026.28

EACH

Datasheet
3WL1116-2CB45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£8,188.84

EACH

Datasheet
3WL1116-2CB42-4GA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£8,361.14

EACH

Datasheet
3WL1116-2CB42-4AN2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC T40= Door sealing frame

£8,395.35

EACH

Datasheet
3WL1116-2CB42-4AA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£8,177.44

EACH

Datasheet
3WL1116-2CB42-1AA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£7,151.22

EACH

Datasheet
3WL1116-2CB41-1AA2
3WL1116-2CB41-1AA2
3WL1116-2CB41-1AA2fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,310.23

EACH

Datasheet
3WL1116-2CB37-4GS7-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 6NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,318.31

EACH

Datasheet
3WL1116-2CB37-4GA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£8,705.11

EACH

Datasheet
3WL1116-2CB37-1AA2
3WL1116-2CB37-1AA2
3WL1116-2CB37-1AA2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,012.48

EACH

Datasheet
3WL1116-2CB36-5FM4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts U01= with label for export to USA

£8,865.89

EACH

Datasheet
3WL1116-2CB36-1GA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC P61= Screwless connection method R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£7,685.88

EACH

Datasheet
3WL1116-2CB36-1FA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock S08= RONIS locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£7,756.82

EACH

Datasheet
3WL1116-2CB36-1CA8-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 5NO+3NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£7,640.26

EACH

Datasheet
3WL1116-2CB36-1BA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£7,457.18

EACH

Datasheet
3WL1116-2CB36-1AA2
3WL1116-2CB36-1AA2
3WL1116-2CB36-1AA2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£6,771.77

EACH

Datasheet
3WL1116-2CB35-5AM8
3WL1116-2CB35-5AM8
3WL1116-2CB35-5AM8withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 5NO+3NC

£7,469.86

EACH

Datasheet
3WL1116-2CB35-4GA2
3WL1116-2CB35-4GA2
3WL1116-2CB35-4GA2withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£7,246.88

EACH

Datasheet
3WL1116-2CB35-1AA4-Zwithdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£6,383.45

EACH

Datasheet
3WL1116-2CB35-1AA4
3WL1116-2CB35-1AA4
3WL1116-2CB35-1AA4withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£6,225.72

EACH

Datasheet
3WL1116-2CB35-1AA2-Zwithdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£6,301.74

EACH

Datasheet
3WL1116-2CB35-1AA2
3WL1116-2CB35-1AA2
3WL1116-2CB35-1AA2withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£6,036.95

EACH

Datasheet
3WL1116-2CB34-4GS4-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£7,615.74

EACH

Datasheet
3WL1116-2CB34-4GS4
3WL1116-2CB34-4GS4
3WL1116-2CB34-4GS4fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC

£7,542.70

EACH

Datasheet
3WL1116-2CB34-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) B12= Rated current reference module 1250 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in S33= Locking device Tension lever T40= Door sealing frame U01= with label for export to USA

£5,964.73

EACH

Datasheet
3WL1116-2CB32-2AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£5,725.91

EACH

Datasheet
3WL1116-2CB32-1FA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£5,725.91

EACH

Datasheet
3WL1116-2CB32-1AR2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 110-127 V AC, 110-125 V DC, 100% ED 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£6,137.04

EACH

Datasheet
3WL1116-2CB32-1AN2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC T40= Door sealing frame

£5,760.12

EACH

Datasheet
3WL1116-2CB32-1AN2
3WL1116-2CB32-1AN2
3WL1116-2CB32-1AN2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£5,602.40

EACH

Datasheet
3WL1116-2CB32-1AA2
3WL1116-2CB32-1AA2
3WL1116-2CB32-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,384.48

EACH

Datasheet
3WL1116-2CB31-4AN2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC C01= mechanical switching cycle counter C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 K10= Remote reset solenoid 24 V DC

£7,531.95

EACH

Datasheet
3WL1116-2CB31-4AN2
3WL1116-2CB31-4AN2
3WL1116-2CB31-4AN2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£6,856.66

EACH

Datasheet
3WL1116-2CB31-1AN2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 S07= Locking device in OFF position w. 4 bracket locks (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2

£5,969.18

EACH

Datasheet
3WL1116-2CB31-1AN2
3WL1116-2CB31-1AN2
3WL1116-2CB31-1AN2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£5,830.45

EACH

Datasheet
3WL1116-2CB31-1AA2
3WL1116-2CB31-1AA2
3WL1116-2CB31-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,612.52

EACH

Datasheet
3WL1116-2BB48-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,096.59

EACH

Datasheet
3WL1116-2BB47-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,533.70

EACH

Datasheet
3WL1116-2BB46-4AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC T40= Door sealing frame

£10,717.65

EACH

Datasheet
3WL1116-2BB46-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,280.31

EACH

Datasheet
3WL1116-2BB46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC T40= Door sealing frame

£9,691.43

EACH

Datasheet
3WL1116-2BB46-1AA2
3WL1116-2BB46-1AA2
3WL1116-2BB46-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£8,684.85

EACH

Datasheet
3WL1116-2BB42-4AA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£8,069.75

EACH

Datasheet
3WL1116-2BB42-1AJ2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC T40= Door sealing frame

£7,261.45

EACH

Datasheet
3WL1116-2BB36-4GA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£7,935.18

EACH

Datasheet
3WL1116-2BB36-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S33= Castell/Fortress Tension lever

£6,789.50

EACH

Datasheet
3WL1116-2BB34-4AN2
3WL1116-2BB34-4AN2
3WL1116-2BB34-4AN2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 15 LI protection adjustable 0.5-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£6,748.98

EACH

Datasheet
3WL1116-2BB33-1AA2
3WL1116-2BB33-1AA2
3WL1116-2BB33-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,504.83

EACH

Datasheet
3WL1116-2BB32-4AA2
3WL1116-2BB32-4AA2
3WL1116-2BB32-4AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£6,303.01

EACH

Datasheet
3WL1116-2BB32-1AA2
3WL1116-2BB32-1AA2
3WL1116-2BB32-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,276.80

EACH

Datasheet
3WL1116-2AA48-1GG2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£9,835.23

EACH

Datasheet
3WL1116-2AA47-4GN4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC C22= Ready-to-close signaling R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£10,803.18

EACH

Datasheet
3WL1116-2AA47-1CA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£8,697.52

EACH

Datasheet
3WL1116-2AA47-1AA4
3WL1116-2AA47-1AA4
3WL1116-2AA47-1AA4withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£8,170.46

EACH

Datasheet
3WL1116-2AA47-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£8,393.45

EACH

Datasheet
3WL1116-2AA46-5FA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling K07= Caution!!! Order code K07 with non-automatic circuit breaker not possible!!! R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£10,224.82

EACH

Datasheet
3WL1116-2AA46-4GA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£9,614.14

EACH

Datasheet
3WL1116-2AA46-4AN2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£9,723.75

EACH

Datasheet
3WL1116-2AA45-6BJ2-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC R57= Mutual mechanical interlock only slide-in circuit breaker 2 m

£8,273.09

EACH

Datasheet
3WL1116-2AA45-4GA2-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R57= Mutual mechanical interlock only slide-in circuit breaker 2 m

£8,055.17

EACH

Datasheet
3WL1116-2AA45-1FA4-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor T40= Door sealing frame

£8,484.24

EACH

Datasheet
3WL1116-2AA45-1AA4-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£7,124.62

EACH

Datasheet
3WL1116-2AA42-1AA2-Zfixed-mount non-aut. circuit-b. 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£6,194.06

EACH

Datasheet
3WL1116-2AA37-4GA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£7,640.89

EACH

Datasheet
3WL1116-2AA37-4BJ2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC R21= Shutter 2-part can be locked with padlock

£7,594.03

EACH

Datasheet
3WL1116-2AA37-1FA4-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2

£6,427.80

EACH

Datasheet
3WL1116-2AA37-1FA2
3WL1116-2AA37-1FA2
3WL1116-2AA37-1FA2withdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£6,131.97

EACH

Datasheet
3WL1116-2AA37-1AA2
3WL1116-2AA37-1AA2
3WL1116-2AA37-1AA2withdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,948.26

EACH

Datasheet
3WL1116-2AA36-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£6,083.20

EACH

Datasheet
3WL1116-2AA36-1AA2
3WL1116-2AA36-1AA2
3WL1116-2AA36-1AA2withdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,707.55

EACH

Datasheet
3WL1116-2AA35-1AA4-Zwithdraw. non-aut. circuit-b. without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£5,319.23

EACH

Datasheet
3WL1116-2AA35-1AA4
3WL1116-2AA35-1AA4
3WL1116-2AA35-1AA4withdraw. non-aut. circuit-b. without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£5,161.50

EACH

Datasheet
3WL1116-2AA33-4GA4-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£6,104.73

EACH

Datasheet
3WL1116-2AA33-4GA4
3WL1116-2AA33-4GA4
3WL1116-2AA33-4GA4fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC

£5,947.00

EACH

Datasheet
3WL1116-2EG48-1EG2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 60 V DC, 100% ON period With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£11,824.96

EACH

Datasheet
3WL1116-2EG48-1FA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC F12= COM16 Modbus module with breaker status sensor F23= Internal current transformers 4-pole switch BGI M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£12,612.98

EACH

Datasheet
3WL1116-2FB36-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£7,590.85

EACH

Datasheet
3WL1116-2FB36-1FA2
3WL1116-2FB36-1FA2
3WL1116-2FB36-1FA2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£7,398.91

EACH

Datasheet
3WL1116-2FB36-1FA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,021.60

EACH

Datasheet
3WL1116-2FB46-1GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,508.40

EACH

Datasheet
3WL1116-2FB46-5FF4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 K12= Remote reset solenoid 120 V AC/125 V DC R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,820.51

EACH

Datasheet
3WL1116-2FB46-5FG4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 4NO+4NC F23= Internal current transformers 4-pole switch BGI P19= Retrofitted to connection: Top flange, bottom horizontal R21= Shutter 2-part can be locked with bracket lock

£11,345.41

EACH

Datasheet
3WL1116-2FB48-1AA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F02= COM15 PROFIBUS module with breaker status sensor F23= Internal current transformers 4-pole switch BGI M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M36= Switch-on solenoid, overexcited 208-240 V AC/220-250 V DC M46= Opening solenoid, overexcited 208-240 V AC/220-250 V DC 5% on-load factor, not for continuous operation R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock

£12,049.83

EACH

Datasheet
3WL1116-2FG35-1AA2-Zwithdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£7,290.58

EACH

Datasheet
3WL1116-2FG46-1AA2
3WL1116-2FG46-1AA2
3WL1116-2FG46-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,888.43

EACH

Datasheet
3WL1116-2FG46-1BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£12,612.36

EACH

Datasheet
3WL1116-2FG46-1BB2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£11,838.89

EACH

Datasheet
3WL1116-2FG46-4AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£12,445.91

EACH

Datasheet
3WL1116-2FG66-6BA2-ZDraw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F38= Metering PLUS required ext.VoltageTransformer I, U, P,W, Q, f, cos phi, harmonics, THD, R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£11,252.29

EACH

Datasheet
3WL1116-2NB36-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,719.31

EACH

Datasheet
3WL1116-2NB36-4GN4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC C22= Ready indicator F02= COM15 PROFIBUS module with breaker status sensor R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£11,439.17

EACH

Datasheet
3WL1116-2NB48-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F12= COM16 Modbus module with breaker status sensor R21= Shutter 2-part can be locked with bracket lock

£11,618.44

EACH

Datasheet
3WL1116-3AA32-1AA2-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£4,864.40

EACH

Datasheet
3WL1116-3AA32-5FA4-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC S30 = LOCKING DEVICE AGAINST OPENING OF CABINET T40= Door sealing frame

£6,402.45

EACH

Datasheet
3WL1116-3AA35-4AN4-Zwithdraw. non-aut. circuit-b. without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£6,797.03

EACH

Datasheet
3WL1116-3AA36-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£6,380.92

EACH

Datasheet
3WL1116-3AA37-1FA4-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with padlock R30= Locking device against opening the control cabinet door T40= Door sealing frame

£8,178.71

EACH

Datasheet
3WL1116-3AA37-4BN2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,062.16

EACH

Datasheet
3WL1116-3AA37-4CN2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,075.46

EACH

Datasheet
3WL1116-3AA42-1FM7-Zfixed-mount non-aut. circuit-b. 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 6NO+2NC C20= Spring charge status indicator not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC S30 = LOCKING DEVICE AGAINST OP. T40= Door sealing frame

£7,962.69

EACH

Datasheet
3WL1116-3AA45-1AA2-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£6,999.18

EACH

Datasheet
3WL1116-3AA45-1FA4-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor

£8,246.48

EACH

Datasheet
3WL1116-3AA46-1AA2
3WL1116-3AA46-1AA2
3WL1116-3AA46-1AA2withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,791.66

EACH

Datasheet
3WL1116-3AA46-1FA4
3WL1116-3AA46-1FA4
3WL1116-3AA46-1FA4withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC

£8,164.14

EACH

Datasheet
3WL1116-3AA46-1FA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£9,727.52

EACH

Datasheet
3WL1116-3AA46-4AN2
3WL1116-3AA46-4AN2
3WL1116-3AA46-4AN2withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£9,035.80

EACH

Datasheet
3WL1116-3AA46-4AN2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,447.55

EACH

Datasheet
3WL1116-3AA46-4AN4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£9,711.70

EACH

Datasheet
3WL1116-3AA46-4GA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£9,910.61

EACH

Datasheet
3WL1116-3AA46-5FM4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC C22= Ready-to-close signaling C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 C27= Auxiliary switching function 2 Auxiliary release not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m

£10,791.53

EACH

Datasheet
3WL1116-3AA47-1AA2
3WL1116-3AA47-1AA2
3WL1116-3AA47-1AA2withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£8,108.39

EACH

Datasheet
3WL1116-3AA47-1AA4
3WL1116-3AA47-1AA4
3WL1116-3AA47-1AA4withdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£8,297.16

EACH

Datasheet
3WL1116-3AA47-1BA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,122.18

EACH

Datasheet
3WL1116-3AA48-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V w. connection flange without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£8,203.41

EACH

Datasheet
3WL1116-3AA48-2AA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V w. connection flange without overcurrent release With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R55= Mutual mechanical interlock for switch with frame 2 m

£8,472.64

EACH

Datasheet
3WL1116-3BB32-1AJ2
3WL1116-3BB32-1AJ2
3WL1116-3BB32-1AJ2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC

£5,881.11

EACH

Datasheet
3WL1116-3BB32-1AJ2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC T40= Door sealing frame

£6,038.86

EACH

Datasheet
3WL1116-3BB48-1FA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V w. connection flange Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,343.66

EACH

Datasheet
3WL1116-3BB78-1AA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V with connecting flange Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£9,299.31

EACH

Datasheet
3WL1116-3CB31-4AN4-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC T40= Door sealing frame

£7,589.59

EACH

Datasheet
3WL1116-3CB32-1AA2
3WL1116-3CB32-1AA2
3WL1116-3CB32-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,770.89

EACH

Datasheet
3WL1116-3CB32-1AA4
3WL1116-3CB32-1AA4
3WL1116-3CB32-1AA4fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£5,959.66

EACH

Datasheet
3WL1116-3CB32-1BA2
3WL1116-3CB32-1BA2
3WL1116-3CB32-1BA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC

£5,954.60

EACH

Datasheet
3WL1116-3CB32-4AA2
3WL1116-3CB32-4AA2
3WL1116-3CB32-4AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£6,797.11

EACH

Datasheet
3WL1116-3CB32-4AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£6,954.84

EACH

Datasheet
3WL1116-3CB32-5FA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£7,054.16

EACH

Datasheet
3WL1116-3CB32-5FM2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02

£7,365.35

EACH

Datasheet
3WL1116-3CB34-4GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 S55= Mutual mechanical Interlock 2 m T40= Door sealing frame

£7,927.22

EACH

Datasheet
3WL1116-3CB35-1AA2
3WL1116-3CB35-1AA2
3WL1116-3CB35-1AA2withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£6,360.02

EACH

Datasheet
3WL1116-3CB36-1AA2
3WL1116-3CB36-1AA2
3WL1116-3CB36-1AA2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,069.50

EACH

Datasheet
3WL1116-3CB36-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£7,445.14

EACH

Datasheet
3WL1116-3CB36-5FA8-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 5NO+3NC R21= Shutter 2-part can be locked with padlock

£8,686.12

EACH

Datasheet
3WL1116-3CB37-5FA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) B16= Rated current reference module 1600 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V S07= Locking device in OFF position w. 4 bracket locks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£9,048.27

EACH

Datasheet
3WL1116-3CB37-5FM2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC C20= Spring charge status indicator not possible with option F02 C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 C27= Auxiliary switching function 2 Auxiliary release not possible with option F02 K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,529.03

EACH

Datasheet
3WL1116-3CB42-1AA2
3WL1116-3CB42-1AA2
3WL1116-3CB42-1AA2fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£7,215.20

EACH

Datasheet
3WL1116-3CB42-1AA2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC N20= Retrofitted to connection: top vertical, bottom horizontal S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£7,492.03

EACH

Datasheet
3WL1116-3CB42-4AA4
3WL1116-3CB42-4AA4
3WL1116-3CB42-4AA4fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£8,430.19

EACH

Datasheet
3WL1116-3CB42-4GA2
3WL1116-3CB42-4GA2
3WL1116-3CB42-4GA2fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£8,425.12

EACH

Datasheet
3WL1116-3CB42-4GN2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC T40= Door sealing frame

£8,800.78

EACH

Datasheet
3WL1116-3CB45-4BA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC C22= Ready-to-close signaling T40= Door sealing frame

£9,376.60

EACH

Datasheet
3WL1116-3CB46-1GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,703.46

EACH

Datasheet
3WL1116-3CB46-4GA2
3WL1116-3CB46-4GA2
3WL1116-3CB46-4GA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£10,065.80

EACH

Datasheet
3WL1116-3CB46-4GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£10,223.53

EACH

Datasheet
3WL1116-3CB47-1AA2
3WL1116-3CB47-1AA2
3WL1116-3CB47-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,172.61

EACH

Datasheet
3WL1116-3CB47-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£9,802.30

EACH

Datasheet
3WL1116-3CB47-1AN2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,112.05

EACH

Datasheet
3WL1116-3CB62-5AM2-ZFixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£7,339.37

EACH

Datasheet
3WL1116-3CB72-1AA2-ZFixed-mounted circuit breaker 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£7,372.93

EACH

Datasheet
3WL1116-3DG32-1FA2
3WL1116-3DG32-1FA2
3WL1116-3DG32-1FA2fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£6,486.71

EACH

Datasheet
3WL1116-3DG32-5FJ4-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame U01= with label for export to USA

£8,203.34

EACH

Datasheet
3WL1116-3DG35-1AP2
3WL1116-3DG35-1AP2
3WL1116-3DG35-1AP2withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 50/60 Hz 380-415 V AC 2NO+2NC

£7,135.39

EACH

Datasheet
3WL1116-3DG43-2AR2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 110-127 V AC, 110-125 V DC, 100% ED 2NO+2NC C11= Electrical On with sealing cap not possible with option F02 F23= Internal current transformers 4-pole switch BGI N61= Cage spring connections for auxiliary S01= CES locking device in Off position Disconnector condition Safe Off/disconnector function S33= Castell/Fortress Tension lever

£9,277.34

EACH

Datasheet
3WL1116-3DG45-1FA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor

£9,906.17

EACH

Datasheet
3WL1116-3DG46-1AA2
3WL1116-3DG46-1AA2
3WL1116-3DG46-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,388.00

EACH

Datasheet
3WL1116-3DG46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£9,875.13

EACH

Datasheet
3WL1116-3DG46-1CA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 M01= Motorized operating mechanism Drive operating mechanism 24-30 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£11,907.31

EACH

Datasheet
3WL1116-3DG46-1CN4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door

£10,618.19

EACH

Datasheet
3WL1116-3DG46-1GA8-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 5NO+3NC K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£10,247.60

EACH

Datasheet
3WL1116-3DG46-4CN2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC B06= Rated current reference module 630 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£11,359.99

EACH

Datasheet
3WL1116-3DG46-4GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock

£11,224.42

EACH

Datasheet
3WL1116-3DG46-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£11,377.08

EACH

Datasheet
3WL1116-3DG46-5FA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£11,389.12

EACH

Datasheet
3WL1116-3DG46-6BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£11,456.89

EACH

Datasheet
3WL1116-3DG46-6BJ4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£11,674.82

EACH

Datasheet
3WL1116-3DG47-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B16= Rated current reference module 1600 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£10,422.45

EACH

Datasheet
3WL1116-3DG48-1CA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V w. connection flange Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£10,494.03

EACH

Datasheet
3WL1116-3DG77-1AA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear vertical connection Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,544.71

EACH

Datasheet
3WL1116-3EB35-1AA4-Zwithdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC T40= Door sealing frame

£6,940.91

EACH

Datasheet
3WL1116-3EB36-1BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F40= Sealing disc for ETU25-76 for protection against unauthorized operation K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,150.02

EACH

Datasheet
3WL1116-3EB36-5FR4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 110-127 V AC, 110-125 V DC, 100% ED 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) F02= COM15 PROFIBUS module with breaker status sensor U01= with label for export to USA

£10,215.76

EACH

Datasheet
3WL1116-3EB37-1CA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with padlock R30= Locking device against opening the control cabinet door T40= Door sealing frame

£8,764.67

EACH

Datasheet
3WL1116-3EB37-6BJ4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) T40= Door sealing frame U01= with label for export to USA

£9,393.50

EACH

Datasheet
3WL1116-3EB45-1AA2
3WL1116-3EB45-1AA2
3WL1116-3EB45-1AA2withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£8,140.07

EACH

Datasheet
3WL1116-3EB45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI T40= Door sealing frame

£8,589.83

EACH

Datasheet
3WL1116-3EB45-1CA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£8,494.81

EACH

Datasheet
3WL1116-3EB45-4CA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC R57= Mutual mechanical interlock only slide-in circuit breaker 2 m T40= Door sealing frame

£9,588.17

EACH

Datasheet
3WL1116-3EB46-4BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,711.95

EACH

Datasheet
3WL1116-3EB47-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,174.38

EACH

Datasheet
3WL1116-3EB47-1BB2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£11,560.79

EACH

Datasheet
3WL1116-3EB47-4CK2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. DC 30V 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£11,698.27

EACH

Datasheet
3WL1116-3EG32-4GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator F40= Sealing disc for ETU25-76 for protection against unauthorized operation K07= Tripped signaling contact, 1 CO not possible with option F02

£8,050.80

EACH

Datasheet
3WL1116-3EG36-1CA2
3WL1116-3EG36-1CA2
3WL1116-3EG36-1CA2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC

£8,115.36

EACH

Datasheet
3WL1116-3EG37-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock R30= Locking device against opening the control cabinet door T40= Door sealing frame

£8,750.10

EACH

Datasheet
3WL1116-3EG37-1CA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock R30= Locking device against opening the control cabinet door S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£9,242.92

EACH

Datasheet
3WL1116-3EG37-1FA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with padlock R30= Locking device against opening the control cabinet door T40= Door sealing frame

£9,966.36

EACH

Datasheet
3WL1116-3EG41-1GA2
3WL1116-3EG41-1GA2
3WL1116-3EG41-1GA2fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£8,558.15

EACH

Datasheet
3WL1116-3EG45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02

£9,006.64

EACH

Datasheet
3WL1116-3EG45-3BA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 230 V AC, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£9,446.29

EACH

Datasheet
3WL1116-3EG46-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£11,821.78

EACH

Datasheet
3WL1116-3EG46-4GJ4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£12,039.70

EACH

Datasheet
3WL1116-3EG46-4GN4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£12,333.63

EACH

Datasheet
3WL1116-3EG47-1CC2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£11,240.26

EACH

Datasheet
3WL1116-3EG47-4BA4
3WL1116-3EG47-4BA4
3WL1116-3EG47-4BA4withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC

£11,420.15

EACH

Datasheet
3WL1116-3EG47-6BJ4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£13,028.56

EACH

Datasheet
3WL1116-3EG47-6CC2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£12,266.48

EACH

Datasheet
3WL1116-3EG47-6CC4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 4NO+4NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£12,348.19

EACH

Datasheet
3WL1116-3EG48-1FA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V w. connection flange Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,300.19

EACH

Datasheet
3WL1116-3EG76-1AA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,426.24

EACH

Datasheet
3WL1116-3EG78-1FA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=66 kA at 500 V with connecting flange Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£10,606.16

EACH

Datasheet
3WL1116-3FB36-1AA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 P18= Retrofitted to connection: top vertical, bottom horizontal R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,266.76

EACH

Datasheet
3WL1116-3FB36-4AN2
3WL1116-3FB36-4AN2
3WL1116-3FB36-4AN2withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC

£8,757.06

EACH

Datasheet
3WL1116-3FB45-1AA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B08= Rated current reference module 800 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion F12= COM16 Modbus module with breaker status sensor

£9,958.89

EACH

Datasheet
3WL1116-3FB46-1AA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 P18= Retrofitted to connection: top vertical, bottom horizontal R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,132.95

EACH

Datasheet
3WL1116-3FB46-4GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£10,666.96

EACH

Datasheet
3WL1116-3FB47-1FA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,064.54

EACH

Datasheet
3WL1116-3FB47-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£11,596.90

EACH

Datasheet
3WL1116-3FG36-4AP2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 50/60 Hz 380-415 V AC 2NO+2NC C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,977.13

EACH

Datasheet
3WL1116-3FG45-2FA2-Zwithdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F23= Internal current transformers 4-pole switch BGI S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£10,491.50

EACH

Datasheet
3WL1116-3FG46-4AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£11,505.67

EACH

Datasheet
3WL1116-3FG46-6BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock

£12,307.02

EACH

Datasheet
3WL1116-3FG47-5FM2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£13,123.56

EACH

Datasheet
3WL1116-3NB46-4GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£12,200.59

EACH

Datasheet
3WL1116-4AA31-4AN4fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC

£6,735.03

EACH

Datasheet
3WL1116-4AA32-1AB2-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 2NO+2NC S07= Locking device in OFF position w. 4 bracket locks (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2 S30 = LOCKING DEVICE AGAINST OPENING OF CABINET S33= Locking device Tension lever

£5,559.94

EACH

Datasheet
3WL1116-4AA37-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£7,090.41

EACH

Datasheet
3WL1116-4CB37-5BM2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,582.48

EACH

Datasheet
3WL1116-4CB46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B12= Rated current reference module 1250 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£9,849.79

EACH

Datasheet
3WL1116-4DG71-1FA2-ZFixed-mounted circuit breaker 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear vertical connection Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F23= Internal current transformers 4-pole switch BGI S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£9,084.57

EACH

Datasheet
3WL1116-4EB38-1AA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£8,527.12

EACH

Datasheet
3WL1116-4EB48-1AA4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,503.54

EACH

Datasheet
3WL1116-4EG36-1DL7
3WL1116-4EG36-1DL7
3WL1116-4EG36-1DL7withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 48 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 48 V DC 6NO+2NC

£9,003.48

EACH

Datasheet
3WL1116-4EG36-1DL7-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 48 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 48 V DC 6NO+2NC C22= Ready indicator K06= 2nd tripped signaling contact, 1 NO (S25) not possible with option F02 or F12 only possible with Z option K07 K07= Tripped signaling contact, 1 CO not possible with option F02 M03= Motor drive, Drive motor 48-60 V DC M23= Switch-on solenoid 48 V DC 100% on-load factor P01= Retrofitted to Connection on front double hole R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£11,099.01

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM