Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3VA24500 A
3VA2450-0MN32-0AA0
3VA2450-0MN32-0AA0
3VA2450-0MN32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=500A overload protection Ir=160A ... 500A short circuit protection Isd=3...12xIr, Ii=12xIn busbar connection

£2,197.71

EACH

Datasheet
3VA2450-0MQ32-0AA0
3VA2450-0MQ32-0AA0
3VA2450-0MQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=500A overload protection Ir=160A ... 500A short circuit protection Isd=1,2...12xIn, Ii=3...12xIn busbar connection

£2,509.82

EACH

Datasheet
3VA2450-0MS32-0AA0
3VA2450-0MS32-0AA0
3VA2450-0MS32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=500A short circuit protection Ii=3...12 x In busbar connection

£1,853.09

EACH

Datasheet
3VA2450-5HK32-0AA0
3VA2450-5HK32-0AA0
3VA2450-5HK32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit

£1,460.61

EACH

Datasheet
3VA2450-5HK32-0AB0
3VA2450-5HK32-0AB0
3VA2450-5HK32-0AB0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut 2 AUXILIARY SWITCH CHANGEOVER H

£1,406.68

EACH

Datasheet
3VA2450-5HK32-0AC0
3VA2450-5HK32-0AC0
3VA2450-5HK32-0AC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415 V 3-pole, line protection ETU340, elisa li, In=500A overload protection ir=200A ...500A short circuit protection iI=14 x In busbar connection circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415 V 3-pole, line protection ETU340, elisa li, In=500A overload protection ir=200A ...500A short circuit protection iI=14 x In busbar 2 auxiliary switch changeover H

£1,391.36

EACH

Datasheet
3VA2450-5HK32-0CC0
3VA2450-5HK32-0CC0
3VA2450-5HK32-0CC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415 V 3-pole, line protection ETU340, elisa li, In=500A overload protection ir=200A ...500A short circuit protection iI=14 x In busbar connection circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415 V 3-pole, line protection ETU340, elisa li, In=500A overload protection ir=200A ...500A short circuit protection iI=14 x In busbar undervoltage release 120-127 V AC 50/60 Hz ACcessory for 3VA1 2 auxiliary switch changeover H

£1,478.32

EACH

Datasheet
3VA2450-5HK32-0DC0
3VA2450-5HK32-0DC0
3VA2450-5HK32-0DC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit Undervoltage release 208-230 V AC 50/60 Hz accessory for 3VA1 2 Auxiliary switch changeover H

£1,478.96

EACH

Datasheet
3VA2450-5HK32-0KK0
3VA2450-5HK32-0KK0
3VA2450-5HK32-0KK0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,482.48

EACH

Datasheet
3VA2450-5HK42-0AA0
3VA2450-5HK42-0AA0
3VA2450-5HK42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£1,880.49

EACH

Datasheet
3VA2450-5HK42-0AF0
3VA2450-5HK42-0AF0
3VA2450-5HK42-0AF0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,826.15

EACH

Datasheet
3VA2450-5JP32-0AA0
3VA2450-5JP32-0AA0
3VA2450-5JP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,829.60

EACH

Datasheet
3VA2450-5JP32-0AF0
3VA2450-5JP32-0AF0
3VA2450-5JP32-0AF0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,772.65

EACH

Datasheet
3VA2450-5JP32-0AH0
3VA2450-5JP32-0AH0
3VA2450-5JP32-0AH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,798.06

EACH

Datasheet
3VA2450-5JP32-0DH0
3VA2450-5JP32-0DH0
3VA2450-5JP32-0DH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,872.97

EACH

Datasheet
3VA2450-5JP32-0KH0
3VA2450-5JP32-0KH0
3VA2450-5JP32-0KH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,852.91

EACH

Datasheet
3VA2450-5JP32-0KK0
3VA2450-5JP32-0KK0
3VA2450-5JP32-0KK0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit shunt trip left 208-277V AC 50/60Hz 1 auxiliary switch 1 trip alarm switch 1 electrical alarm switch

£1,866.29

EACH

Datasheet
3VA2450-5JP32-0LA0
3VA2450-5JP32-0LA0
3VA2450-5JP32-0LA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=500A UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up

£1,893.01

EACH

Datasheet
3VA2450-5JP42-0AA0
3VA2450-5JP42-0AA0
3VA2450-5JP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,279.73

EACH

Datasheet
3VA2450-5JP42-0AF0
3VA2450-5JP42-0AF0
3VA2450-5JP42-0AF0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU550, LSI, In=500A overload protection 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£2,210.71

EACH

Datasheet
3VA2450-5JQ32-0AA0
3VA2450-5JQ32-0AA0
3VA2450-5JQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,018.38

EACH

Datasheet
3VA2450-5JQ32-0LC0
3VA2450-5JQ32-0LC0
3VA2450-5JQ32-0LC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H

£2,101.68

EACH

Datasheet
3VA2450-5JQ42-0AA0
3VA2450-5JQ42-0AA0
3VA2450-5JQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,475.77

EACH

Datasheet
3VA2450-5KP32-0AA0
3VA2450-5KP32-0AA0
3VA2450-5KP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£1,974.81

EACH

Datasheet
3VA2450-5KP42-0AA0
3VA2450-5KP42-0AA0
3VA2450-5KP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,439.47

EACH

Datasheet
3VA2450-5KQ32-0AA0
3VA2450-5KQ32-0AA0
3VA2450-5KQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,105.50

EACH

Datasheet
3VA2450-5KQ42-0AA0
3VA2450-5KQ42-0AA0
3VA2450-5KQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,548.39

EACH

Datasheet
3VA2450-5MN32-0AA0
3VA2450-5MN32-0AA0
3VA2450-5MN32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit

£1,503.88

EACH

Datasheet
3VA2450-5MN32-0AB0
3VA2450-5MN32-0AB0
3VA2450-5MN32-0AB0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP

£1,786.03

EACH

Datasheet
3VA2450-5MN32-0AC0
3VA2450-5MN32-0AC0
3VA2450-5MN32-0AC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ

£1,772.65

EACH

Datasheet
3VA2450-5MN32-0AD0
3VA2450-5MN32-0AD0
3VA2450-5MN32-0AD0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 3 auxiliary switches HQ

£1,786.03

EACH

Datasheet
3VA2450-5MN32-0AE0
3VA2450-5MN32-0AE0
3VA2450-5MN32-0AE0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 4 auxiliary switches HQ

£1,806.08

EACH

Datasheet
3VA2450-5MN32-0AF0
3VA2450-5MN32-0AF0
3VA2450-5MN32-0AF0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£1,772.65

EACH

Datasheet
3VA2450-5MN32-0AG0
3VA2450-5MN32-0AG0
3VA2450-5MN32-0AG0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£1,786.03

EACH

Datasheet
3VA2450-5MN32-0AH0
3VA2450-5MN32-0AH0
3VA2450-5MN32-0AH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,786.03

EACH

Datasheet
3VA2450-5MN32-0AJ0
3VA2450-5MN32-0AJ0
3VA2450-5MN32-0AJ0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£1,812.77

EACH

Datasheet
3VA2450-5MN32-0BA0
3VA2450-5MN32-0BA0
3VA2450-5MN32-0BA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,812.77

EACH

Datasheet
3VA2450-5MN32-0BC0
3VA2450-5MN32-0BC0
3VA2450-5MN32-0BC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0BE0
3VA2450-5MN32-0BE0
3VA2450-5MN32-0BE0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 4 AUXILIARY SWITCH CHANGEOVER H

£1,893.01

EACH

Datasheet
3VA2450-5MN32-0BF0
3VA2450-5MN32-0BF0
3VA2450-5MN32-0BF0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£1,853.09

EACH

Datasheet
3VA2450-5MN32-0BH0
3VA2450-5MN32-0BH0
3VA2450-5MN32-0BH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,866.29

EACH

Datasheet
3VA2450-5MN32-0BL0
3VA2450-5MN32-0BL0
3VA2450-5MN32-0BL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,893.04

EACH

Datasheet
3VA2450-5MN32-0CA0
3VA2450-5MN32-0CA0
3VA2450-5MN32-0CA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,812.77

EACH

Datasheet
3VA2450-5MN32-0CC0
3VA2450-5MN32-0CC0
3VA2450-5MN32-0CC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0CH0
3VA2450-5MN32-0CH0
3VA2450-5MN32-0CH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,866.29

EACH

Datasheet
3VA2450-5MN32-0CL0
3VA2450-5MN32-0CL0
3VA2450-5MN32-0CL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,893.04

EACH

Datasheet
3VA2450-5MN32-0DA0
3VA2450-5MN32-0DA0
3VA2450-5MN32-0DA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£1,812.77

EACH

Datasheet
3VA2450-5MN32-0DC0
3VA2450-5MN32-0DC0
3VA2450-5MN32-0DC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0DE0
3VA2450-5MN32-0DE0
3VA2450-5MN32-0DE0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V undervoltage release 208-230V AC 50/60Hz 4 auxiliary switches HQ

£1,893.04

EACH

Datasheet
3VA2450-5MN32-0DH0
3VA2450-5MN32-0DH0
3VA2450-5MN32-0DH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,866.29

EACH

Datasheet
3VA2450-5MN32-0DL0
3VA2450-5MN32-0DL0
3VA2450-5MN32-0DL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,893.04

EACH

Datasheet
3VA2450-5MN32-0HA0
3VA2450-5MN32-0HA0
3VA2450-5MN32-0HA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£1,799.39

EACH

Datasheet
3VA2450-5MN32-0HC0
3VA2450-5MN32-0HC0
3VA2450-5MN32-0HC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£1,832.85

EACH

Datasheet
3VA2450-5MN32-0HH0
3VA2450-5MN32-0HH0
3VA2450-5MN32-0HH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0HL0
3VA2450-5MN32-0HL0
3VA2450-5MN32-0HL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,872.97

EACH

Datasheet
3VA2450-5MN32-0JA0
3VA2450-5MN32-0JA0
3VA2450-5MN32-0JA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£1,799.39

EACH

Datasheet
3VA2450-5MN32-0JC0
3VA2450-5MN32-0JC0
3VA2450-5MN32-0JC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£1,832.85

EACH

Datasheet
3VA2450-5MN32-0JH0
3VA2450-5MN32-0JH0
3VA2450-5MN32-0JH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0JL0
3VA2450-5MN32-0JL0
3VA2450-5MN32-0JL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,872.97

EACH

Datasheet
3VA2450-5MN32-0KA0
3VA2450-5MN32-0KA0
3VA2450-5MN32-0KA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£1,799.39

EACH

Datasheet
3VA2450-5MN32-0KC0
3VA2450-5MN32-0KC0
3VA2450-5MN32-0KC0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£1,832.85

EACH

Datasheet
3VA2450-5MN32-0KH0
3VA2450-5MN32-0KH0
3VA2450-5MN32-0KH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£1,846.22

EACH

Datasheet
3VA2450-5MN32-0KJ0
3VA2450-5MN32-0KJ0
3VA2450-5MN32-0KJ0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HP 1 trip alarm switch HP

£1,872.97

EACH

Datasheet
3VA2450-5MN32-0KL0
3VA2450-5MN32-0KL0
3VA2450-5MN32-0KL0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£1,872.97

EACH

Datasheet
3VA2450-5MP32-0AA0
3VA2450-5MP32-0AA0
3VA2450-5MP32-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=500A OVERLOAD PROTECTION IR=200A ...500A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION

£1,806.08

EACH

Datasheet
3VA2450-5MP32-0AE0
3VA2450-5MP32-0AE0
3VA2450-5MP32-0AE0CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=500A OVERLOAD PROTECTION IR=200A ...500A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION 4 AUXILIARY SWITCH CHANGEOVER H

£2,524.24

EACH

Datasheet
3VA2450-5MP32-0DH0
3VA2450-5MP32-0DH0
3VA2450-5MP32-0DH0CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=500A OVERLOAD PROTECTION IR=200A ...500A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=500A OVERLOAD PROTECTION IR=200A ...500A SHORT CIRCUIT UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£3,184.57

EACH

Datasheet
3VA2450-5MQ32-0AA0
3VA2450-5MQ32-0AA0
3VA2450-5MQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,063.93

EACH

Datasheet
3VA2450-5MQ32-0DH0
3VA2450-5MQ32-0DH0
3VA2450-5MQ32-0DH0circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15x In, Ii=3..15x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 2 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£2,051.64

EACH

Datasheet
3VA2450-6HK32-0AA0
3VA2450-6HK32-0AA0
3VA2450-6HK32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit

£1,618.46

EACH

Datasheet
3VA2450-6HK42-0AA0
3VA2450-6HK42-0AA0
3VA2450-6HK42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£2,142.51

EACH

Datasheet
3VA2450-6JP32-0AA0
3VA2450-6JP32-0AA0
3VA2450-6JP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£2,018.38

EACH

Datasheet
3VA2450-6JP42-0AA0
3VA2450-6JP42-0AA0
3VA2450-6JP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,541.11

EACH

Datasheet
3VA2450-6JQ32-0AA0
3VA2450-6JQ32-0AA0
3VA2450-6JQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,207.14

EACH

Datasheet
3VA2450-6JQ32-0DK0
3VA2450-6JQ32-0DK0
3VA2450-6JQ32-0DK0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A ...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection opt. w. ext. CT, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,254.27

EACH

Datasheet
3VA2450-6JQ32-0KA0
3VA2450-6JQ32-0KA0
3VA2450-6JQ32-0KA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£2,173.99

EACH

Datasheet
3VA2450-6JQ42-0AA0
3VA2450-6JQ42-0AA0
3VA2450-6JQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,744.41

EACH

Datasheet
3VA2450-6KP32-0AA0
3VA2450-6KP32-0AA0
3VA2450-6KP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£2,178.11

EACH

Datasheet
3VA2450-6KP32-0DA0
3VA2450-6KP32-0DA0
3VA2450-6KP32-0DA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU850, LSI, In=500A UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1

£2,165.20

EACH

Datasheet
3VA2450-6KP42-0AA0
3VA2450-6KP42-0AA0
3VA2450-6KP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,715.37

EACH

Datasheet
3VA2450-6KQ32-0AA0
3VA2450-6KQ32-0AA0
3VA2450-6KQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,287.00

EACH

Datasheet
3VA2450-6KQ42-0AA0
3VA2450-6KQ42-0AA0
3VA2450-6KQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,817.01

EACH

Datasheet
3VA2450-7HK32-0AA0
3VA2450-7HK32-0AA0
3VA2450-7HK32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In nut keeper kit

£1,749.48

EACH

Datasheet
3VA2450-7HK42-0AA0
3VA2450-7HK42-0AA0
3VA2450-7HK42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=14 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£2,319.78

EACH

Datasheet
3VA2450-7JP32-0AA0
3VA2450-7JP32-0AA0
3VA2450-7JP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£2,149.07

EACH

Datasheet
3VA2450-7JP42-0AA0
3VA2450-7JP42-0AA0
3VA2450-7JP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,722.63

EACH

Datasheet
3VA2450-7JQ32-0AA0
3VA2450-7JQ32-0AA0
3VA2450-7JQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,352.35

EACH

Datasheet
3VA2450-7JQ42-0AA0
3VA2450-7JQ42-0AA0
3VA2450-7JQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU560, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,918.67

EACH

Datasheet
3VA2450-7KP32-0AA0
3VA2450-7KP32-0AA0
3VA2450-7KP32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% nut keeper kit

£2,316.04

EACH

Datasheet
3VA2450-7KP42-0AA0
3VA2450-7KP42-0AA0
3VA2450-7KP42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU850, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit

£2,882.36

EACH

Datasheet
3VA2450-7KQ32-0AA0
3VA2450-7KQ32-0AA0
3VA2450-7KQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,424.95

EACH

Datasheet
3VA2450-7KQ42-0AA0
3VA2450-7KQ42-0AA0
3VA2450-7KQ42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=0.6..10x In, Ii=1.5..14x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit

£2,998.52

EACH

Datasheet
3VA2450-7MN32-0AA0
3VA2450-7MN32-0AA0
3VA2450-7MN32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit

£2,156.33

EACH

Datasheet
3VA2450-7MN32-0AB0
3VA2450-7MN32-0AB0
3VA2450-7MN32-0AB0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP

£2,107.10

EACH

Datasheet
3VA2450-7MN32-0AC0
3VA2450-7MN32-0AC0
3VA2450-7MN32-0AC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ

£2,093.72

EACH

Datasheet
3VA2450-7MN32-0AD0
3VA2450-7MN32-0AD0
3VA2450-7MN32-0AD0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 3 auxiliary switches HQ

£2,107.10

EACH

Datasheet
3VA2450-7MN32-0AE0
3VA2450-7MN32-0AE0
3VA2450-7MN32-0AE0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 4 auxiliary switches HQ

£2,127.17

EACH

Datasheet
3VA2450-7MN32-0AF0
3VA2450-7MN32-0AF0
3VA2450-7MN32-0AF0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£2,093.72

EACH

Datasheet
3VA2450-7MN32-0AG0
3VA2450-7MN32-0AG0
3VA2450-7MN32-0AG0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£2,107.10

EACH

Datasheet
3VA2450-7MN32-0AH0
3VA2450-7MN32-0AH0
3VA2450-7MN32-0AH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,107.10

EACH

Datasheet
3VA2450-7MN32-0AJ0
3VA2450-7MN32-0AJ0
3VA2450-7MN32-0AJ0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit 2 auxiliary switches HP 1 trip alarm switch HP

£2,133.85

EACH

Datasheet
3VA2450-7MN32-0BA0
3VA2450-7MN32-0BA0
3VA2450-7MN32-0BA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£2,133.85

EACH

Datasheet
3VA2450-7MN32-0BC0
3VA2450-7MN32-0BC0
3VA2450-7MN32-0BC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0BH0
3VA2450-7MN32-0BH0
3VA2450-7MN32-0BH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,194.06

EACH

Datasheet
3VA2450-7MN32-0BL0
3VA2450-7MN32-0BL0
3VA2450-7MN32-0BL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,220.81

EACH

Datasheet
3VA2450-7MN32-0CA0
3VA2450-7MN32-0CA0
3VA2450-7MN32-0CA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£2,133.85

EACH

Datasheet
3VA2450-7MN32-0CC0
3VA2450-7MN32-0CC0
3VA2450-7MN32-0CC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0CH0
3VA2450-7MN32-0CH0
3VA2450-7MN32-0CH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,194.06

EACH

Datasheet
3VA2450-7MN32-0CL0
3VA2450-7MN32-0CL0
3VA2450-7MN32-0CL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,220.81

EACH

Datasheet
3VA2450-7MN32-0DA0
3VA2450-7MN32-0DA0
3VA2450-7MN32-0DA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£2,133.85

EACH

Datasheet
3VA2450-7MN32-0DC0
3VA2450-7MN32-0DC0
3VA2450-7MN32-0DC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0DH0
3VA2450-7MN32-0DH0
3VA2450-7MN32-0DH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,194.06

EACH

Datasheet
3VA2450-7MN32-0DL0
3VA2450-7MN32-0DL0
3VA2450-7MN32-0DL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,220.81

EACH

Datasheet
3VA2450-7MN32-0HA0
3VA2450-7MN32-0HA0
3VA2450-7MN32-0HA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£2,120.48

EACH

Datasheet
3VA2450-7MN32-0HC0
3VA2450-7MN32-0HC0
3VA2450-7MN32-0HC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£2,160.61

EACH

Datasheet
3VA2450-7MN32-0HH0
3VA2450-7MN32-0HH0
3VA2450-7MN32-0HH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0HL0
3VA2450-7MN32-0HL0
3VA2450-7MN32-0HL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,207.44

EACH

Datasheet
3VA2450-7MN32-0JA0
3VA2450-7MN32-0JA0
3VA2450-7MN32-0JA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£2,120.48

EACH

Datasheet
3VA2450-7MN32-0JC0
3VA2450-7MN32-0JC0
3VA2450-7MN32-0JC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£2,160.61

EACH

Datasheet
3VA2450-7MN32-0JH0
3VA2450-7MN32-0JH0
3VA2450-7MN32-0JH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0JL0
3VA2450-7MN32-0JL0
3VA2450-7MN32-0JL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,207.44

EACH

Datasheet
3VA2450-7MN32-0KA0
3VA2450-7MN32-0KA0
3VA2450-7MN32-0KA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£2,120.48

EACH

Datasheet
3VA2450-7MN32-0KC0
3VA2450-7MN32-0KC0
3VA2450-7MN32-0KC0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£2,160.61

EACH

Datasheet
3VA2450-7MN32-0KH0
3VA2450-7MN32-0KH0
3VA2450-7MN32-0KH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£2,173.99

EACH

Datasheet
3VA2450-7MN32-0KL0
3VA2450-7MN32-0KL0
3VA2450-7MN32-0KL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU350M, LSI, In=500A overload protection Ir=200A...500A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,207.44

EACH

Datasheet
3VA2450-7MP32-0AA0
3VA2450-7MP32-0AA0
3VA2450-7MP32-0AA0CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=500A OVERLOAD PROTECTION IR=200A ...500A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION

£2,127.17

EACH

Datasheet
3VA2450-7MQ32-0AA0
3VA2450-7MQ32-0AA0
3VA2450-7MQ32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15 x In, Ii=3..15 x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit

£2,345.08

EACH

Datasheet
3VA2450-7MQ32-0BK0
3VA2450-7MQ32-0BK0
3VA2450-7MQ32-0BK0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15 x In, Ii=3..15 x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£2,379.68

EACH

Datasheet
3VA2450-7MQ32-0BL0
3VA2450-7MQ32-0BL0
3VA2450-7MQ32-0BL0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2...15 x In, Ii=15 x In gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch

£2,394.73

EACH

Datasheet
3VA2450-7MQ32-0JH0
3VA2450-7MQ32-0JH0
3VA2450-7MQ32-0JH0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15 x In, Ii=3..15 x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit shunt trip left 110-127V AC 50/60Hz/DC 2 auxiliary switches 1 trip alarm switch

£2,347.91

EACH

Datasheet
3VA2450-7MQ32-0LK0
3VA2450-7MQ32-0LK0
3VA2450-7MQ32-0LK0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection Ir=200A...500A short-circuit protection Isd=1.2..15 x In, Ii=3..15 x In gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, motor protection ETU860M, LSIG, In=500A overload protection UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£2,441.56

EACH

Datasheet
3VA2450-7MS32-0AA0
3VA2450-7MS32-0AA0
3VA2450-7MS32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=500A without overload protection short-circuit protection Ii=3...15 x In nut keeper kit

£1,695.52

EACH

Datasheet
3VA2450-7MS32-0DK0
3VA2450-7MS32-0DK0
3VA2450-7MS32-0DK0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=500A without overload protection short-circuit protection Ii=3...15 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=500A without overload protection short-circuit protection Ii=3...15 x In nut UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER 1 electrical alarm switch HQ

£1,766.39

EACH

Datasheet
3VA2450-7MS32-0KG0
3VA2450-7MS32-0KG0
3VA2450-7MS32-0KG0circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection ETU310M, I, In=500A without overload protection short-circuit protection Ii=3...15 x In nut keeper kit circuit breaker 3VA2 IEC frame 630 breaking capacity class C Icu=110kA @ 415V 3-pole, starter protection shunt trip left 208-277V AC 50/60Hz 1 auxiliary switch HP 1 trip alarm switch HP

£1,739.20

EACH

Datasheet
3VA2450-8HK32-0AA0
3VA2450-8HK32-0AA0
3VA2450-8HK32-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class L Icu=150kA @ 415V 3-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=11 x In nut keeper kit

£1,918.12

EACH

Datasheet
3VA2450-8HK42-0AA0
3VA2450-8HK42-0AA0
3VA2450-8HK42-0AA0circuit breaker 3VA2 IEC frame 630 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU340, ELISA LI, In=500A overload protection Ir=200A...500A short-circuit protection Ii=11 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit

£2,548.83

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM