CataloguesSiemensPower Breakers3WL13 - Frame Size 34000 A
3WL1340-4AA36-4GS2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 2NO+2NC P23= Retrofitted to Connection: Top horizontal, bottom vertical

£21,534.75

EACH

Datasheet
3WL1340-4AA37-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£21,026.71

EACH

Datasheet
3WL1340-4AA37-4GS2
3WL1340-4AA37-4GS2
3WL1340-4AA37-4GS2withdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 2NO+2NC

£22,075.72

EACH

Datasheet
3WL1340-4AA37-5AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£21,945.87

EACH

Datasheet
3WL1340-4AA38-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£20,013.16

EACH

Datasheet
3WL1340-4AA38-4GA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door

£21,097.67

EACH

Datasheet
3WL1340-4AA45-1FA4-Zwithdraw. non-aut. circuit-b. without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor T40= Door sealing frame

£25,841.26

EACH

Datasheet
3WL1340-4AA46-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£28,521.89

EACH

Datasheet
3WL1340-4AA46-1CA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£30,422.93

EACH

Datasheet
3WL1340-4AA46-1FA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling K07= Caution!!! Order code K07 with non-automatic circuit breaker not possible!!! M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor P18= Retrofitted to connection: top vertical, bottom horizontal R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£30,540.95

EACH

Datasheet
3WL1340-4AA48-4GA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door

£29,606.39

EACH

Datasheet
3WL1340-4AA76-1BJ2-ZWithdrawable non-automatic air circuit breaker with slide-in module frame 4-pole, Size 3, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear horizontal connection without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£28,955.82

EACH

Datasheet
3WL1340-4AA78-1AA2-ZWithdrawable non-automatic air circuit breaker with slide-in module frame 4-pole, Size 3, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=100 kA at 500 V with connecting flange without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£29,352.36

EACH

Datasheet
3WL1340-4CB31-4GA4-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC A05= Version for 1000 V K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame

£20,440.11

EACH

Datasheet
3WL1340-4CB31-5FA2-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC S30 = LOCKING DEVICE AGAINST OP.

£17,870.14

EACH

Datasheet
3WL1340-4CB32-5FA4
3WL1340-4CB32-5FA4
3WL1340-4CB32-5FA4fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC

£16,905.99

EACH

Datasheet
3WL1340-4CB32-5FA4-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 K07= Tripped signaling contact, 1 CO not possible with option F02 S30 = LOCKING DEVICE AGAINST OP.

£17,148.81

EACH

Datasheet
3WL1340-4CB35-4GA2
3WL1340-4CB35-4GA2
3WL1340-4CB35-4GA2withdrawable circuit breaker without guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£18,871.01

EACH

Datasheet
3WL1340-4CB36-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock

£20,812.59

EACH

Datasheet
3WL1340-4CB36-4GA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£22,180.26

EACH

Datasheet
3WL1340-4CB36-4GB4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 24 V DC; 100% on-load factor 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£22,616.09

EACH

Datasheet
3WL1340-4CB36-4GN2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC A08= Tin plating of customer terminals in slide-in unit frame for horizontal connection or flange connection K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R30= Locking device against opening of the control cabinet door S07= Castell/Fortress in Off position with 4 padlocks S33= Castell/Fortress Tension lever T40= Door sealing frame

£22,987.29

EACH

Datasheet
3WL1340-4CB36-4GN4
3WL1340-4CB36-4GN4
3WL1340-4CB36-4GN4withdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC

£22,001.60

EACH

Datasheet
3WL1340-4CB36-5AM2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£22,417.18

EACH

Datasheet
3WL1340-4CB37-4GS2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 2NO+2NC R21= Shutter 2-part can be locked with padlock

£23,567.54

EACH

Datasheet
3WL1340-4CB37-5BM2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£23,411.72

EACH

Datasheet
3WL1340-4CB41-1AA2-Zfixed-mounted circuit breaker 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£20,922.81

EACH

Datasheet
3WL1340-5CB31-1AA2
3WL1340-5CB31-1AA2
3WL1340-5CB31-1AA2fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 1150V, AC50/60Hz Icu=150kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£20,448.34

EACH

Datasheet
3WL1340-5AA32-4GG4-Zfixed-mount non-aut. circuit-b. 3-pole, size III, IEC In=4000A to 1150V, AC50/60Hz Icu=150kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 4NO+4NC S07= Locking device in OFF position w. 4 padlock (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2

£20,155.05

EACH

Datasheet
3WL1340-5AA32-4GG4
3WL1340-5AA32-4GG4
3WL1340-5AA32-4GG4fixed-mount non-aut. circuit-b. 3-pole, size III, IEC In=4000A to 1150V, AC50/60Hz Icu=150kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 4NO+4NC

£20,079.66

EACH

Datasheet
3WL1340-4NG37-6BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 76 LSING protection adjustable 0.4-1 in with graphic display U cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSI Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F01= Breaker status sensor without COM15 PROFIBUS module F40= Sealing disc for ETU25-76 for protection against unauthorized operation R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock S33= Castell/Fortress Tension lever T40= Door sealing frame

£26,353.97

EACH

Datasheet
3WL1340-4NG31-6BA4-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 76 LSING protection adjustable 0.4-1 in with graphic display U cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSI Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F01= Breaker status sensor without COM15 PROFIBUS module F40= Sealing disc for ETU25-76 for protection against unauthorized operation K10= Remote reset magnet 24 V DC S05= Fortress locking device in OFF position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 S30 = LOCKING DEVICE AGAINST OP. S33= Locking device Tension lever T40= Door sealing frame

£21,439.52

EACH

Datasheet
3WL1340-4NG31-1AA4-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 76 LSING protection adjustable 0.4-1 in with graphic display U cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSI With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F01= Breaker status sensor without COM15 PROFIBUS module F40= Sealing disc for ETU25-76 for protection against unauthorized operation K10= Remote reset magnet 24 V DC S05= Fortress locking device in OFF position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 S30 = LOCKING DEVICE AGAINST OP. S33= Locking device Tension lever T40= Door sealing frame

£20,229.61

EACH

Datasheet
3WL1340-4NB46-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£33,341.32

EACH

Datasheet
3WL1340-4NB37-5FA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A05= Version for 1000 V B16= Rated current reference module 1600 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F01= Breaker status sensor without COM15 PROFIBUS module F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion U01= with label for export to USA

£27,893.86

EACH

Datasheet
3WL1340-4NB35-5FA2-Zwithdrawable circuit breaker without guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A05= Version for 1000 V B16= Rated current reference module 1600 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F01= Breaker status sensor without COM15 PROFIBUS module F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion U01= with label for export to USA

£24,169.27

EACH

Datasheet
3WL1340-4FG46-4GC8-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 5NO+3NC R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£32,520.98

EACH

Datasheet
3WL1340-4FG46-1BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R21= Shutter 2-part can be locked with bracket lock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£32,559.68

EACH

Datasheet
3WL1340-4FG32-4GN2-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC A05= Version for 1000 V K07= Tripped signaling contact, 1 CO not possible with option F02 S07= Locking device in OFF position w. 4 padlock (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£20,626.99

EACH

Datasheet
3WL1340-4FB67-1FA2-ZDraw-out circuit breaker with slide-in module frame 3-pole, Size 3, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear vertical connection Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£22,611.01

EACH

Datasheet
3WL1340-4FB42-4GS4-Zfixed-mounted circuit breaker 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC T40= Door sealing frame

£22,029.48

EACH

Datasheet
3WL1340-4FB38-1BA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£21,704.52

EACH

Datasheet
3WL1340-4FB37-5BM4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion F12= COM16 Modbus module with breaker status sensor S07= Castell/Fortress in Off position with 4 padlocks U01= with label for export to USA

£25,517.40

EACH

Datasheet
3WL1340-4FB37-4GA4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£24,235.86

EACH

Datasheet
3WL1340-4EG47-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC F23= Internal current converter 4-pole switch BGIII K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks

£31,883.70

EACH

Datasheet
3WL1340-4EG46-1FA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor P23= Retrofitted to Connection: Top horizontal, bottom vertical R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£32,517.38

EACH

Datasheet
3WL1340-4EG45-1AA4-Zwithdrawable circuit breaker without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC F23= Internal current converter 4-pole switch BGIII T40= Door sealing frame

£26,582.20

EACH

Datasheet
3WL1340-4EG41-1GA2
3WL1340-4EG41-1GA2
3WL1340-4EG41-1GA2fixed-mounted circuit breaker 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£21,797.64

EACH

Datasheet
3WL1340-4EG37-1AC2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£23,200.14

EACH

Datasheet
3WL1340-4EB76-6BJ2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 3, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear horizontal connection Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC C22= Ready-to-close signaling R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£31,383.92

EACH

Datasheet
3WL1340-4EB38-5FM4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£23,024.03

EACH

Datasheet
3WL1340-4EB37-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£22,218.27

EACH

Datasheet
3WL1340-4EB36-5BM4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame U01= with label for export to USA

£23,328.07

EACH

Datasheet
3WL1340-4EB36-5BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame U01= with label for export to USA

£23,110.32

EACH

Datasheet
3WL1340-4EB36-4GA4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door

£22,891.64

EACH

Datasheet
3WL1340-4EB36-4BN4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts U01= with label for export to USA

£22,740.02

EACH

Datasheet
3WL1340-4EB36-4AS4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 S07= Castell/Fortress in Off position with 4 padlocks

£22,504.58

EACH

Datasheet
3WL1340-4EB36-1AA4-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£20,897.48

EACH

Datasheet
3WL1340-4EB35-5FA2-Zwithdrawable circuit breaker without guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02

£19,272.01

EACH

Datasheet
3WL1340-4EB32-1AG2
3WL1340-4EB32-1AG2
3WL1340-4EB32-1AG2fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "F", F2 Shunt release 230 V AC/220 V DC, 100% on-load factor 2NO+2NC

£15,925.39

EACH

Datasheet
3WL1340-4EB31-6BA2
3WL1340-4EB31-6BA2
3WL1340-4EB31-6BA2fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC

£17,965.15

EACH

Datasheet
3WL1340-4DG78-1AA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 3, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=100 kA at 500 V with connecting flange Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£30,948.70

EACH

Datasheet
3WL1340-4DG48-5CM7-Zwithdrawable circuit breaker with guide frame 4-pole, size iii, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 6NO+2NC B32= Rated current reference module 3200 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£31,793.12

EACH

Datasheet
3WL1340-4DG46-4DA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 48 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£31,703.81

EACH

Datasheet
3WL1340-4DG46-1CA4-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC B32= Rated current reference module 3200 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in C20= Spring charge status indicator not possible with option F02 F23= Internal current converter 4-pole switch BGIII M01= Motorized operating mechanism Drive operating mechanism 24-30 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£31,705.70

EACH

Datasheet
3WL1340-4DG46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B32= Rated current reference module 3200 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in P23= Retrofitted to Connection: Top horizontal, bottom vertical R21= Shutter 2-part can be locked with bracket lock

£30,480.58

EACH

Datasheet
3WL1340-4DG45-1FA4-Zwithdrawable circuit breaker without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C11= Electrical On with sealing cap not possible with option F02 C22= Ready-to-close signaling F23= Internal current converter 4-pole switch BGIII K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor T40= Door sealing frame

£27,688.44

EACH

Datasheet
3WL1340-4DG45-1CA2
3WL1340-4DG45-1CA2
3WL1340-4DG45-1CA2withdrawable circuit breaker without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC

£25,928.48

EACH

Datasheet
3WL1340-4DG45-1AA4
3WL1340-4DG45-1AA4
3WL1340-4DG45-1AA4withdrawable circuit breaker without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£25,920.23

EACH

Datasheet
3WL1340-4DG38-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£21,609.50

EACH

Datasheet
3WL1340-4DG35-4GP2
3WL1340-4DG35-4GP2
3WL1340-4DG35-4GP2withdrawable circuit breaker without guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 50/60 Hz 380-415 V AC 2NO+2NC

£19,646.38

EACH

Datasheet
3WL1340-4DG32-4GA4-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC A05= Version for 1000 V K07= Tripped signaling contact, 1 CO not possible with option F02 N20= Retrofitted to Connection: top vertical, bottom horizontal T40= Door sealing frame

£20,431.24

EACH

Datasheet
3WL1340-4DG32-1FA2
3WL1340-4DG32-1FA2
3WL1340-4DG32-1FA2fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£16,223.12

EACH

Datasheet
3WL1340-4DG32-1AA2-Zfixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC N24= Retrofitted to Connection: top horizontal, bottom vertical

£16,511.97

EACH

Datasheet
3WL1340-4DG32-1AA2
3WL1340-4DG32-1AA2
3WL1340-4DG32-1AA2fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£16,039.41

EACH

Datasheet
3WL1340-4CB46-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m

£31,523.91

EACH

Datasheet
3WL1340-4CB46-4GA4
3WL1340-4CB46-4GA4
3WL1340-4CB46-4GA4withdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC

£30,208.82

EACH

Datasheet
3WL1340-4CB46-4GA2
3WL1340-4CB46-4GA2
3WL1340-4CB46-4GA2withdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£30,020.05

EACH

Datasheet
3WL1340-4CB46-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with bracket lock S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£30,215.15

EACH

Datasheet
3WL1340-4CB46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock

£29,321.33

EACH

Datasheet
3WL1340-4CB42-4GA2-Zfixed-mounted circuit breaker 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC N20= Retrofitted to connection: top vertical, bottom horizontal T40= Door sealing frame

£21,492.93

EACH

Datasheet
3WL1340-4CB42-1FF4-Zfixed-mounted circuit breaker 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 4NO+4NC C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 S07= Castell/Fortress in Off position with 4 padlocks S30 = LOCKING DEVICE AGAINST OP. S33= Castell/Fortress Tension lever T40= Door sealing frame

£20,718.83

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM