Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3WL11 - Frame Size 12000 A
3WL1120-2AA34-4GA2-Zfixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£6,409.52

EACH

Datasheet
3WL1120-2AA46-4AN4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC C22= Ready-to-close signaling R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£10,733.49

EACH

Datasheet
3WL1120-2BB32-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC N61= Cage spring connections for auxiliary S30 = LOCKING DEVICE AGAINST OPENING OF CABINET

£6,048.99

EACH

Datasheet
3WL1120-2BB47-1BA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,547.24

EACH

Datasheet
3WL1120-2BB48-1AA2
3WL1120-2BB48-1AA2
3WL1120-2BB48-1AA2withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£9,635.05

EACH

Datasheet
3WL1120-2CB32-1AA2
3WL1120-2CB32-1AA2
3WL1120-2CB32-1AA2fixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£5,941.93

EACH

Datasheet
3WL1120-2CB32-1AM2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 2NO+2NC T40= Door sealing frame

£6,317.58

EACH

Datasheet
3WL1120-2CB32-1AN2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC T40= Door sealing frame

£6,317.58

EACH

Datasheet
3WL1120-2CB32-1GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£6,283.37

EACH

Datasheet
3WL1120-2CB34-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) B12= Rated current reference module 1250 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in S33= Locking device Tension lever T40= Door sealing frame U01= with label for export to USA

£6,544.91

EACH

Datasheet
3WL1120-2CB36-5FM4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 R16= Position signaling switch, withdrawable part 6 changeover contacts U01= with label for export to USA

£9,603.65

EACH

Datasheet
3WL1120-2CB72-1AA2-ZFixed-mounted circuit breaker 4-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC B16= Rated current reference module 1600 A for ETU25, 27, 45, 55, 75, 76 for setting rated current in F40= Sealing disc for ETU25-76 for protection against unauthorized operation S30 = LOCKING DEVICE AGAINST OP. S33= Castell/Fortress Tension lever T40= Door sealing frame

£8,236.16

EACH

Datasheet
3WL1120-2DG41-1AN2-Zfixed-mounted circuit breaker 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC F23= Internal current transformers 4-pole switch BGI T40= Door sealing frame

£9,170.09

EACH

Datasheet
3WL1120-2EB32-4GN2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC S30 = LOCKING DEVICE AGAINST OPENING OF CABINET S55= Mutual mechanical Interlock 2 m T40= Door sealing frame

£8,398.53

EACH

Datasheet
3WL1120-2EB34-4GA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator K07= Tripped signaling contact, 1 CO not possible with option F02 U01= with label for export to USA

£7,873.16

EACH

Datasheet
3WL1120-2EB36-4GS4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 P23= Retrofitted to Connection: Top horizontal, bottom vertical

£9,906.17

EACH

Datasheet
3WL1120-3AA41-4FA2-Zfixed-mount non-aut. circuit-b. 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£8,665.20

EACH

Datasheet
3WL1120-3AA42-1FA7-Zfixed-mount non-aut. circuit-b. 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 6NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor T40= Door sealing frame

£8,530.90

EACH

Datasheet
3WL1120-3AA76-5FF2-ZWithdrawable non-automatic air circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 2NO+2NC C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£10,802.09

EACH

Datasheet
3WL1120-3AA77-1BA4-ZWithdrawable non-automatic air circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear vertical connection without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R86= RONIS locking device against in isolated position

£11,534.82

EACH

Datasheet
3WL1120-3CB32-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S30 = LOCKING DEVICE AGAINST OPENING OF CABINET

£6,512.05

EACH

Datasheet
3WL1120-3CB32-4AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£7,556.63

EACH

Datasheet
3WL1120-3CB47-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with bracket lock

£10,784.79

EACH

Datasheet
3WL1120-3EB37-6BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 U01= with label for export to USA

£9,891.59

EACH

Datasheet
3WL1120-3EB37-6BJ4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 U01= with label for export to USA

£10,109.34

EACH

Datasheet
3WL1120-3EG46-6BJ2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover On not possible with option A05 Rated voltage 1000 V R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock

£12,964.57

EACH

Datasheet
3WL1120-3EG77-1BC4-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear vertical connection Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 4NO+4NC C22= Ready-to-close signaling F23= Internal current transformers 4-pole switch BGI K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock R86= RONIS locking device against in isolated position

£13,811.50

EACH

Datasheet
3WL1120-3FB32-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S07= Locking device in OFF position w. 4 bracket locks (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2 T40= Door sealing frame

£7,049.23

EACH

Datasheet
3WL1120-3FB35-4GA8
3WL1120-3FB35-4GA8
3WL1120-3FB35-4GA8withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 5NO+3NC

£8,879.95

EACH

Datasheet
3WL1120-3FB46-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£10,661.27

EACH

Datasheet
3WL1120-3FG46-6AJ2-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 2NO+2NC F23= Internal current transformers 4-pole switch BGI R21= Shutter 2-part can be locked with bracket lock S05= Castell/Fortress locking device in Off position Disconnector condition Safe Off/disconnector function S07= Castell/Fortress in Off position with 4 padlocks

£12,685.84

EACH

Datasheet
3WL1120-3FG62-1CA4-ZFixed-mounted circuit breaker 3-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready indicator C26= Auxiliary switching function 1st auxiliary release not possible with option F02 F40= Sealing disc for ETU25-76 for protection against unauthorized operation K07= Tripped signaling contact, 1 CO not possible with option F02 S05= Fortress locking device in OFF position (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2 S33= Locking device Tension lever T40= Door sealing frame

£8,485.95

EACH

Datasheet
3WL1120-3NB35-1BA2-Zwithdrawable circuit breaker without guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor T40= Door sealing frame

£10,071.51

EACH

Datasheet
3WL1120-4BB32-1AA2-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC S07= Locking device in OFF position w. 4 bracket locks (safe OFF/disconnector functionality) Disconnector condition IEC 60947-2 S30 = LOCKING DEVICE AGAINST OPENING OF CABINET T40= Door sealing frame

£6,960.55

EACH

Datasheet
3WL1120-4BB32-1GA2
3WL1120-4BB32-1GA2
3WL1120-4BB32-1GA2fixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

£6,771.77

EACH

Datasheet
3WL1120-4BB78-1AA2-ZDraw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=2000 A to 690 V, 50/60 Hz AC Icu=85 kA at 500 V with connecting flange Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£10,882.98

EACH

Datasheet
3WL1120-4CB46-4GN4-Zwithdrawable circuit breaker with guide frame 4-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 4NO+4NC R21= Shutter 2-part can be locked with bracket lock R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£12,965.20

EACH

Datasheet
3WL1120-4EB32-6AJ4-Zfixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£8,437.28

EACH

Datasheet
3WL1120-4EB37-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£9,212.53

EACH

Datasheet
3WL1120-4EB37-6BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame U01= with label for export to USA

£10,514.02

EACH

Datasheet
3WL1120-4EB38-5FA4-Zwithdrawable circuit breaker with guide frame 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=85kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock U01= with label for export to USA

£10,288.40

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM