• Electrika Logo
  • Company
    • About Us
    • Contact Us
  • Products
    • Catalogues
    • Favourites
  • Price Downloads
  • Software
    • Online Estimating
    • Desktop Estimating
    • Desktop Downloads
  • News
  • Blog
  • Sign In
  • |
  • Register

All Companies

Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3WL12 - Frame Size 24000 A
3WL1240-2AA47-1AA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function

£22,086.49

EACH

Datasheet
3WL1240-2BB31-1BA2-Zfixed-mounted circuit breaker 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£12,078.97

EACH

Datasheet
3WL1240-2DG37-1AA2
3WL1240-2DG37-1AA2
3WL1240-2DG37-1AA2withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£17,306.34

EACH

Datasheet
3WL1240-2EB37-6BJ4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) T40= Door sealing frame U01= with label for export to USA

£18,762.29

EACH

Datasheet
3WL1240-2EG37-1FA4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2

£18,551.74

EACH

Datasheet
3WL1240-2FB41-4GA2-Zfixed-mounted circuit breaker 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£17,951.84

EACH

Datasheet
3WL1240-3AA31-4GN2-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC S55= Mutual mechanical Interlock 2 m

£13,770.97

EACH

Datasheet
3WL1240-3AA47-1FA4-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£25,170.86

EACH

Datasheet
3WL1240-3AA77-5FF2-ZWithdrawable non-automatic air circuit breaker with slide-in module frame 4-pole, Size 2, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear vertical connection without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 2NO+2NC C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock S07= Castell/Fortress in Off position with 4 padlocks T40= Door sealing frame

£24,534.40

EACH

Datasheet
3WL1240-3CB37-1AM4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock S07= Castell/Fortress in Off position with 4 padlock (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame U01= with label for export to USA

£18,776.17

EACH

Datasheet
3WL1240-3CB37-6BJ4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock T40= Door sealing frame

£19,491.81

EACH

Datasheet
3WL1240-3CB41-1AA2
3WL1240-3CB41-1AA2
3WL1240-3CB41-1AA2fixed-mounted circuit breaker 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£17,027.62

EACH

Datasheet
3WL1240-3CB41-1AA2-Zfixed-mounted circuit breaker 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£17,185.35

EACH

Datasheet
3WL1240-3CB47-1AA2
3WL1240-3CB47-1AA2
3WL1240-3CB47-1AA2withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£23,488.99

EACH

Datasheet
3WL1240-3EB37-5BA4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) U01= with label for export to USA

£19,103.95

EACH

Datasheet
3WL1240-3EB37-5BM4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period With 2nd auxiliary release "R", F3 Undervoltage, instant. 110-127 V AC, 110-125 V DC 4NO+4NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 R10= Arc chute cover withdrawable part not possible with option A05 Rated voltage 1000 V R21= Shutter 2-part can be locked with padlock S07= Castell/Fortress in Off position with 4 padlock (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame U01= with label for export to USA

£20,081.20

EACH

Datasheet
3WL1240-3EB47-1FA4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£25,792.28

EACH

Datasheet
3WL1240-3EG37-1FA2-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door T40= Door sealing frame

£19,047.12

EACH

Datasheet
3WL1240-3EG41-1AA2
3WL1240-3EG41-1AA2
3WL1240-3EG41-1AA2fixed-mounted circuit breaker 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£17,876.47

EACH

Datasheet
3WL1240-3EG41-1AA2-Zfixed-mounted circuit breaker 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£18,034.19

EACH

Datasheet
3WL1240-3EG47-1FF4
3WL1240-3EG47-1FF4
3WL1240-3EG47-1FF4withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 4NO+4NC

£24,894.02

EACH

Datasheet
3WL1240-3EG47-1FF4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 4NO+4NC F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£27,456.42

EACH

Datasheet
3WL1240-3FB31-1FA2-Zfixed-mounted circuit breaker 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£13,694.95

EACH

Datasheet
3WL1240-3FB47-1FA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F23= Internal current converter 4-pole switch BGII R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£24,842.08

EACH

Datasheet
3WL1240-3FB47-4GA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=80kA at 500V rear connection vertical Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£25,300.07

EACH

Datasheet
3WL1240-4AA37-1AA2-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£17,868.23

EACH

Datasheet
3WL1240-4AA47-1CA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£24,786.33

EACH

Datasheet
3WL1240-4AA47-1FA2-Zwithdraw. non-aut. circuit-b. with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC M05= Motor drive, Drive motor AC 50/60 Hz 110-127 V AC or 110-125 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£25,698.53

EACH

Datasheet
3WL1240-4CB37-1AA2-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door T40= Door sealing frame

£18,964.76

EACH

Datasheet
3WL1240-4CB47-1CA4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£27,717.40

EACH

Datasheet
3WL1240-4DG31-1FA2-Zfixed-mounted circuit breaker 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

£14,860.52

EACH

Datasheet
3WL1240-4DG37-1FA4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 M05= Motor drive, Drive motor AC 50/60 Hz 110-127 V AC or 110-125 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door T40= Door sealing frame

£21,104.62

EACH

Datasheet
3WL1240-4EB37-6BA2-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor 24-30 V DC Activation 24 V DC With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 2NO+2NC A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) K07= Tripped signaling contact, 1 CO not possible with option F02 T40= Door sealing frame U01= with label for export to USA

£20,138.53

EACH

Datasheet
3WL1240-4EB47-1FF4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "F", F2 Shunt release 110 V AC/DC 100% on-load factor 4NO+4NC K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£27,432.96

EACH

Datasheet
3WL1240-4EG37-1AC2-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release With 2nd auxiliary release "F", F2 Shunt release 30 V DC, 100% on-load factor 2NO+2NC K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with padlock S05= Fortress locking device in Off position (safe OFF/disconnector functionality) Disconnector condition in compliance with IEC 60947-2 T40= Door sealing frame

£20,041.65

EACH

Datasheet
3WL1240-4EG37-1FR4-Zwithdrawable circuit breaker with guide frame 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 110-127 V AC, 110-125 V DC, 100% ED 4NO+4NC C26= Auxiliary switching function 1 Auxiliary release not possible with option F02 C27= Auxiliary switching function 2 Auxiliary release not possible with option F02 K07= Tripped signaling contact, 1 CO not possible with option F02 M05= Motor drive, Drive motor AC 50/60 Hz 110-127 V AC or 110-125 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor R15= Position signaling switch, withdrawable part 3 changeover contacts R21= Shutter 2-part can be locked with padlock R30= Locking device against opening of the control cabinet door T40= Door sealing frame

£22,033.03

EACH

Datasheet
3WL1240-4EG45-1AA4draw-out circuit breaker without guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear terminals horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC

£21,422.61

EACH

Datasheet
3WL1240-4EG47-1AA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£26,691.17

EACH

Datasheet
3WL1240-4EG47-1BA4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 24 V DC; 100% ON period without 2nd auxiliary release 4NO+4NC C22= Ready-to-close signaling K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M21= Switch-on solenoid 24 V DC 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£28,571.31

EACH

Datasheet
3WL1240-4EG47-1CA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£26,888.17

EACH

Datasheet
3WL1240-4EG47-1CA4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 4NO+4NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M22= Switch-on solenoid 30 V DC 100% on-load factor R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£28,691.67

EACH

Datasheet
3WL1240-4EG47-1DA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 48 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC C20= Spring charge status indicator not possible with option F02 C22= Ready-to-close signaling F23= Internal current converter 4-pole switch BGII M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M23= Switch-on solenoid 48 V DC 100% on-load factor R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door R55= Mutual mechanical interlock for switch with frame 2 m T40= Door sealing frame

£28,682.81

EACH

Datasheet
3WL1240-4EG47-1GA7-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 6NO+2NC C22= Ready-to-close signaling F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M26= Switch-on solenoid 208-240 V AC/220-250 V DC, 100% on-load factor R16= Position signaling switch, withdrawable part 6 changeover contacts R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door T40= Door sealing frame

£29,587.00

EACH

Datasheet
3WL1240-4EG47-4GA4-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock T40= Door sealing frame

£27,843.44

EACH

Datasheet
3WL1240-4FG47-1CA2-Zwithdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with display and cubicle bus with ground fault protection Opt.: Comm./measuring func./ZSS With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 30 V DC, 100% ON period without 2nd auxiliary release 2NO+2NC F23= Internal current converter 4-pole switch BGII K07= Tripped signaling contact, 1 CO not possible with option F02 R21= Shutter 2-part can be locked with bracket lock R30= Locking device against opening of the Control cabinet door S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function T40= Door sealing frame

£27,135.23

EACH

Datasheet
3WL1240-4NB31-1AA2
3WL1240-4NB31-1AA2
3WL1240-4NB31-1AA2fixed-mounted circuit breaker 3-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical Overcurrent release ETU 76 LSI protection adjustable 0.4-1 in with graphic display U cubicle bus Communication/ground fault/ ZSS option With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC

£15,646.66

EACH

Datasheet
3WL1240-8AA31-5AJ4-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 600V DC rear connection vertical without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£17,949.31

EACH

Datasheet
3WL1240-8AA32-1AA4-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 600V DC rear connection horizontal without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£15,912.25

EACH

Datasheet
3WL1240-8AA32-3FA4-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 600V DC rear connection horizontal without overcurrent release With manual operating mechanism with storage with electrical + mechanical request 50/60 Hz 230 V AC, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC A05= Version for 1000 V S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2

£16,101.72

EACH

Datasheet
3WL1240-8AA32-4GN2-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 600V DC rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V DC 2NO+2NC A05= Version for 1000 V C01= mechanical switching cycle counter N61= Cage spring connections for auxiliary S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2

£17,380.47

EACH

Datasheet
3WL1240-8AA32-5AJ4-Zfixed-mount non-aut. circuit-b. 3-pole, size II, IEC In=4000A to 600V DC rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator S07= Castell/Fortress in Off position with 4 padlocks (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£17,161.43

EACH

Datasheet
3WL1240-8AA38-1AA4-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size II, IEC In=4000A to 600V DC w. connection flange without overcurrent release With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) S07= Castell/Fortress in Off position with 4 padlock (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£21,108.77

EACH

Datasheet
3WL1240-8AA38-5AJ4-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size II, IEC In=4000A to 600V DC w. connection flange without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator S07= Castell/Fortress in Off position with 4 padlock (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£22,461.81

EACH

Datasheet
3WL1240-8AA38-5FJ4-Zwithdraw. non-aut. circuit-b. with guide frame 3-pole, size II, IEC In=4000A to 600V DC w. connection flange without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor With 2nd auxiliary release "R", F3 Undervoltage, instant. 24 V DC 4NO+4NC A05= Version for 1000 V A61= Special packaging for increased transport requirements, for foam packaging carton packaging with wax coating (moisture protection) C22= Ready indicator S07= Castell/Fortress in Off position with 4 padlock (Safe Off/disconnector function) Disconnector condition in compliance with IEC 60947-2 U01= with label for export to USA

£22,645.17

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM