• Electrika Logo
  • Company
    • About Us
    • Contact Us
  • Products
    • Catalogues
    • Favourites
  • Price Downloads
  • Software
    • Online Estimating
    • Desktop Estimating
    • Desktop Downloads
  • News
  • Blog
  • Sign In
  • |
  • Register

All Companies

Siemens

Siemens

https://mall.industry.siemens.com/goos/WelcomePage.aspx?language=en&regionUrl=/uk0161 446 6400adukmarketing@siemens.comWhere To Buy
CataloguesTrade Price List01/01/2024
CataloguesSiemensPower Breakers3VA11125 A
3VA1112-4EF32-0JH0
3VA1112-4EF32-0JH0
3VA1112-4EF32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£485.95

EACH

Datasheet
3VA1112-4EF32-0JC0
3VA1112-4EF32-0JC0
3VA1112-4EF32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£467.92

EACH

Datasheet
3VA1112-4EF32-0JA0
3VA1112-4EF32-0JA0
3VA1112-4EF32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£431.17

EACH

Datasheet
3VA1112-4EF32-0HH0
3VA1112-4EF32-0HH0
3VA1112-4EF32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£485.95

EACH

Datasheet
3VA1112-4EF32-0HC0
3VA1112-4EF32-0HC0
3VA1112-4EF32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£467.92

EACH

Datasheet
3VA1112-4EF32-0HA0
3VA1112-4EF32-0HA0
3VA1112-4EF32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£431.17

EACH

Datasheet
3VA1112-4EF32-0DH0
3VA1112-4EF32-0DH0
3VA1112-4EF32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£505.94

EACH

Datasheet
3VA1112-4EF32-0DC0
3VA1112-4EF32-0DC0
3VA1112-4EF32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£486.60

EACH

Datasheet
3VA1112-4EF32-0DA0
3VA1112-4EF32-0DA0
3VA1112-4EF32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£450.50

EACH

Datasheet
3VA1112-4EF32-0CH0
3VA1112-4EF32-0CH0
3VA1112-4EF32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£505.94

EACH

Datasheet
3VA1112-4EF32-0CC0
3VA1112-4EF32-0CC0
3VA1112-4EF32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£486.60

EACH

Datasheet
3VA1112-4EF32-0CA0
3VA1112-4EF32-0CA0
3VA1112-4EF32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£450.50

EACH

Datasheet
3VA1112-4EF32-0BH0
3VA1112-4EF32-0BH0
3VA1112-4EF32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£505.94

EACH

Datasheet
3VA1112-4EF32-0BC0
3VA1112-4EF32-0BC0
3VA1112-4EF32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£486.60

EACH

Datasheet
3VA1112-4EF32-0BA0
3VA1112-4EF32-0BA0
3VA1112-4EF32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£450.50

EACH

Datasheet
3VA1112-4EF32-0AH0
3VA1112-4EF32-0AH0
3VA1112-4EF32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£420.86

EACH

Datasheet
3VA1112-4EF32-0AG0
3VA1112-4EF32-0AG0
3VA1112-4EF32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£420.86

EACH

Datasheet
3VA1112-4EF32-0AF0
3VA1112-4EF32-0AF0
3VA1112-4EF32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£401.53

EACH

Datasheet
3VA1112-4EF32-0AE0
3VA1112-4EF32-0AE0
3VA1112-4EF32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 4 auxiliary switches HQ

£440.20

EACH

Datasheet
3VA1112-4EF32-0AD0
3VA1112-4EF32-0AD0
3VA1112-4EF32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 3 auxiliary switches HQ

£420.86

EACH

Datasheet
3VA1112-4EF32-0AC0
3VA1112-4EF32-0AC0
3VA1112-4EF32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ

£401.53

EACH

Datasheet
3VA1112-4EF32-0AB0
3VA1112-4EF32-0AB0
3VA1112-4EF32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HP

£420.86

EACH

Datasheet
3VA1112-4EF32-0AA0
3VA1112-4EF32-0AA0
3VA1112-4EF32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit

£270.31

EACH

Datasheet
3VA1112-4EE46-0AA0
3VA1112-4EE46-0AA0
3VA1112-4EE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£407.50

EACH

Datasheet
3VA1112-4EE42-0AA0
3VA1112-4EE42-0AA0
3VA1112-4EE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£390.07

EACH

Datasheet
3VA1112-4EE36-0AA0
3VA1112-4EE36-0AA0
3VA1112-4EE36-0AA0MCCB_IEC_FS160_125A_3P_36KA_TM_ ATFM

£278.17

EACH

Catalogue
Datasheet
3VA1112-4EE32-0BF0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£469.21

EACH

Datasheet
3VA1112-4EF32-0KA0
3VA1112-4EF32-0KA0
3VA1112-4EF32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£431.17

EACH

Datasheet
3VA1112-4EF32-0KC0
3VA1112-4EF32-0KC0
3VA1112-4EF32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£467.92

EACH

Datasheet
3VA1112-4EF32-0KH0
3VA1112-4EF32-0KH0
3VA1112-4EF32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£485.95

EACH

Datasheet
3VA1112-4EF36-0AA0
3VA1112-4EF36-0AA0
3VA1112-4EF36-0AA0MCCB_IEC_FS160_125A_3P_36KA_TM_ ATAM

£298.37

EACH

Catalogue
Datasheet
3VA1112-4FD42-0AA0
3VA1112-4FD42-0AA0
3VA1112-4FD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£344.81

EACH

Datasheet
3VA1112-4EF46-0AA0
3VA1112-4EF46-0AA0
3VA1112-4EF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

£441.01

EACH

Datasheet
3VA1112-4EF42-0AA0
3VA1112-4EF42-0AA0
3VA1112-4EF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

£410.73

EACH

Datasheet
3VA1112-4EF36-0KH0
3VA1112-4EF36-0KH0
3VA1112-4EF36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£504.00

EACH

Datasheet
3VA1112-4EF36-0KC0
3VA1112-4EF36-0KC0
3VA1112-4EF36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£485.32

EACH

Datasheet
3VA1112-4EF36-0KA0
3VA1112-4EF36-0KA0
3VA1112-4EF36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC

£449.22

EACH

Datasheet
3VA1112-4EF36-0JH0
3VA1112-4EF36-0JH0
3VA1112-4EF36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£504.00

EACH

Datasheet
3VA1112-4EF36-0JC0
3VA1112-4EF36-0JC0
3VA1112-4EF36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£485.32

EACH

Datasheet
3VA1112-4EF36-0JA0
3VA1112-4EF36-0JA0
3VA1112-4EF36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£449.22

EACH

Datasheet
3VA1112-4EF36-0HH0
3VA1112-4EF36-0HH0
3VA1112-4EF36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£504.00

EACH

Datasheet
3VA1112-4EF36-0HC0
3VA1112-4EF36-0HC0
3VA1112-4EF36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£485.32

EACH

Datasheet
3VA1112-4EF36-0HA0
3VA1112-4EF36-0HA0
3VA1112-4EF36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£449.22

EACH

Datasheet
3VA1112-4EF36-0DH0
3VA1112-4EF36-0DH0
3VA1112-4EF36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-4EE32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit

£236.20

EACH

Datasheet
3VA1112-4EF36-0DC0
3VA1112-4EF36-0DC0
3VA1112-4EF36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-4EF36-0CH0
3VA1112-4EF36-0CH0
3VA1112-4EF36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-4EF36-0CC0
3VA1112-4EF36-0CC0
3VA1112-4EF36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-4EF36-0CA0
3VA1112-4EF36-0CA0
3VA1112-4EF36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£469.20

EACH

Datasheet
3VA1112-4EF36-0BH0
3VA1112-4EF36-0BH0
3VA1112-4EF36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-4EF36-0BC0
3VA1112-4EF36-0BC0
3VA1112-4EF36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-4EF36-0BA0
3VA1112-4EF36-0BA0
3VA1112-4EF36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC

£469.20

EACH

Datasheet
3VA1112-4EF36-0AH0
3VA1112-4EF36-0AH0
3VA1112-4EF36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£439.55

EACH

Datasheet
3VA1112-4EF36-0AG0
3VA1112-4EF36-0AG0
3VA1112-4EF36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£439.55

EACH

Datasheet
3VA1112-4EF36-0AF0
3VA1112-4EF36-0AF0
3VA1112-4EF36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£420.22

EACH

Datasheet
3VA1112-4EF36-0AE0
3VA1112-4EF36-0AE0
3VA1112-4EF36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 4 auxiliary switches HQ

£456.94

EACH

Datasheet
3VA1112-4EF36-0AD0
3VA1112-4EF36-0AD0
3VA1112-4EF36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 3 auxiliary switches HQ

£439.55

EACH

Datasheet
3VA1112-4EF36-0AC0
3VA1112-4EF36-0AC0
3VA1112-4EF36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ

£420.22

EACH

Datasheet
3VA1112-4EF36-0AB0
3VA1112-4EF36-0AB0
3VA1112-4EF36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HP

£439.55

EACH

Datasheet
3VA1112-4EF36-0DA0
3VA1112-4EF36-0DA0
3VA1112-4EF36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£469.20

EACH

Datasheet
3VA1112-4FD46-0AA0
3VA1112-4FD46-0AA0
3VA1112-4FD46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£362.23

EACH

Datasheet
3VA1112-4ED46-0AA0
3VA1112-4ED46-0AA0
3VA1112-4ED46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£399.34

EACH

Datasheet
3VA1112-4ED36-0AC0
3VA1112-4ED36-0AC0
3VA1112-4ED36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection 2 auxiliary switch changeover H

£393.80

EACH

Datasheet
3VA1112-3EF36-0DC0
3VA1112-3EF36-0DC0
3VA1112-3EF36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£475.00

EACH

Datasheet
3VA1112-3EF36-0DA0
3VA1112-3EF36-0DA0
3VA1112-3EF36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£439.55

EACH

Datasheet
3VA1112-3EF36-0CH0
3VA1112-3EF36-0CH0
3VA1112-3EF36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£494.33

EACH

Datasheet
3VA1112-3EF36-0CC0
3VA1112-3EF36-0CC0
3VA1112-3EF36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£475.00

EACH

Datasheet
3VA1112-3EF36-0CA0
3VA1112-3EF36-0CA0
3VA1112-3EF36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£439.55

EACH

Datasheet
3VA1112-3EF36-0BH0
3VA1112-3EF36-0BH0
3VA1112-3EF36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£494.33

EACH

Datasheet
3VA1112-3EF36-0BC0
3VA1112-3EF36-0BC0
3VA1112-3EF36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£475.00

EACH

Datasheet
3VA1112-3EF36-0BA0
3VA1112-3EF36-0BA0
3VA1112-3EF36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC

£439.55

EACH

Datasheet
3VA1112-3EF36-0AH0
3VA1112-3EF36-0AH0
3VA1112-3EF36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£408.61

EACH

Datasheet
3VA1112-3EF36-0AG0
3VA1112-3EF36-0AG0
3VA1112-3EF36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£408.61

EACH

Datasheet
3VA1112-3EF36-0AF0
3VA1112-3EF36-0AF0
3VA1112-3EF36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£390.58

EACH

Datasheet
3VA1112-3EF36-0AE0
3VA1112-3EF36-0AE0
3VA1112-3EF36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 4 auxiliary switches HQ

£426.02

EACH

Datasheet
3VA1112-3EF36-0AD0
3VA1112-3EF36-0AD0
3VA1112-3EF36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 3 auxiliary switches HQ

£408.61

EACH

Datasheet
3VA1112-3EF36-0AC0
3VA1112-3EF36-0AC0
3VA1112-3EF36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ

£390.58

EACH

Datasheet
3VA1112-3EF36-0AB0
3VA1112-3EF36-0AB0
3VA1112-3EF36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HP

£408.61

EACH

Datasheet
3VA1112-3EF36-0AA0
3VA1112-3EF36-0AA0
3VA1112-3EF36-0AA0MCCB_IEC_FS160_125A_3P_25KA_TM_ ATAM

£329.40

EACH

Catalogue
Datasheet
3VA1112-3EF32-0KH0
3VA1112-3EF32-0KH0
3VA1112-3EF32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£456.94

EACH

Datasheet
3VA1112-3EF32-0KC0
3VA1112-3EF32-0KC0
3VA1112-3EF32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£439.55

EACH

Datasheet
3VA1112-3EF32-0KA0
3VA1112-3EF32-0KA0
3VA1112-3EF32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£401.53

EACH

Datasheet
3VA1112-3EF32-0JH0
3VA1112-3EF32-0JH0
3VA1112-3EF32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£456.94

EACH

Datasheet
3VA1112-3EF32-0JC0
3VA1112-3EF32-0JC0
3VA1112-3EF32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£439.55

EACH

Datasheet
3VA1112-3EF32-0JA0
3VA1112-3EF32-0JA0
3VA1112-3EF32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£401.53

EACH

Datasheet
3VA1112-3EF32-0HH0
3VA1112-3EF32-0HH0
3VA1112-3EF32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£456.94

EACH

Datasheet
3VA1112-3EF32-0HC0
3VA1112-3EF32-0HC0
3VA1112-3EF32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£439.55

EACH

Datasheet
3VA1112-3EF32-0HA0
3VA1112-3EF32-0HA0
3VA1112-3EF32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£401.53

EACH

Datasheet
3VA1112-3EF32-0DH0
3VA1112-3EF32-0DH0
3VA1112-3EF32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£476.28

EACH

Datasheet
3VA1112-3EF32-0DC0
3VA1112-3EF32-0DC0
3VA1112-3EF32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£457.60

EACH

Datasheet
3VA1112-3EF36-0DH0
3VA1112-3EF36-0DH0
3VA1112-3EF36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£494.33

EACH

Datasheet
3VA1112-3EF36-0HA0
3VA1112-3EF36-0HA0
3VA1112-3EF36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£419.58

EACH

Datasheet
3VA1112-3EF36-0HC0
3VA1112-3EF36-0HC0
3VA1112-3EF36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£455.66

EACH

Datasheet
3VA1112-3EF36-0HH0
3VA1112-3EF36-0HH0
3VA1112-3EF36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£474.35

EACH

Datasheet
3VA1112-4ED36-0AA0
3VA1112-4ED36-0AA0
3VA1112-4ED36-0AA0MCCB_IEC_FS160_125A_3P_36KA_TM_ FTFM

£257.32

EACH

Catalogue
Datasheet
3VA1112-4ED32-0KF0
3VA1112-4ED32-0KF0
3VA1112-4ED32-0KF0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ

£442.77

EACH

Datasheet
3VA1112-4ED32-0AA0
3VA1112-4ED32-0AA0
3VA1112-4ED32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£224.39

EACH

Datasheet
3VA1112-4ED26-0AA0
3VA1112-4ED26-0AA0
3VA1112-4ED26-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection

£265.01

EACH

Datasheet
3VA1112-4ED22-0AA0
3VA1112-4ED22-0AA0
3VA1112-4ED22-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£252.52

EACH

Datasheet
3VA1112-4ED16-0AA0
3VA1112-4ED16-0AA0
3VA1112-4ED16-0AA0MCCB_IEC_FS160_125A_1P_36KA_TM_ FTFM

£139.48

EACH

Catalogue
Datasheet
3VA1112-4ED12-0AA0
3VA1112-4ED12-0AA0
3VA1112-4ED12-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 240V 1-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£129.25

EACH

Datasheet
3VA1112-3GF46-0AA0
3VA1112-3GF46-0AA0
3VA1112-3GF46-0AA0MCCB_IEC_FS160_125A_4P_25KA_TM_ ATAM

£458.69

EACH

Catalogue
Datasheet
3VA1112-3GF42-0AA0
3VA1112-3GF42-0AA0
3VA1112-3GF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit

£407.67

EACH

Datasheet
3VA1112-3GE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£345.92

EACH

Datasheet
3VA1112-3GD46-0AA0
3VA1112-3GD46-0AA0
3VA1112-3GD46-0AA0MCCB_IEC_FS160_125A_4P_25KA_TM_ FTFM

£373.41

EACH

Catalogue
Datasheet
3VA1112-3GD42-0AA0
3VA1112-3GD42-0AA0
3VA1112-3GD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£328.63

EACH

Datasheet
3VA1112-4ED42-0AA0
3VA1112-4ED42-0AA0
3VA1112-4ED42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£381.93

EACH

Datasheet
3VA1112-3FF46-0AA0
3VA1112-3FF46-0AA0
3VA1112-3FF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% clamp connection

£416.36

EACH

Datasheet
3VA1112-3FE46-0AA0
3VA1112-3FE46-0AA0
3VA1112-3FE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£363.35

EACH

Datasheet
3VA1112-3FE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£345.92

EACH

Datasheet
3VA1112-3FD46-0AA0
3VA1112-3FD46-0AA0
3VA1112-3FD46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£346.05

EACH

Datasheet
3VA1112-3FD42-0AA0
3VA1112-3FD42-0AA0
3VA1112-3FD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£328.63

EACH

Datasheet
3VA1112-3EF46-0AA0
3VA1112-3EF46-0AA0
3VA1112-3EF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

£407.63

EACH

Datasheet
3VA1112-3EF42-0AA0
3VA1112-3EF42-0AA0
3VA1112-3EF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

£390.20

EACH

Datasheet
3VA1112-3EF36-0KH0
3VA1112-3EF36-0KH0
3VA1112-3EF36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£474.35

EACH

Datasheet
3VA1112-3EF36-0KC0
3VA1112-3EF36-0KC0
3VA1112-3EF36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£455.66

EACH

Datasheet
3VA1112-3EF36-0KA0
3VA1112-3EF36-0KA0
3VA1112-3EF36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC

£419.58

EACH

Datasheet
3VA1112-3EF36-0JM0
3VA1112-3EF36-0JM0
3VA1112-3EF36-0JM0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip left 110-127V AC 50/60Hz/DC 2 auxiliary switches 1 short circuit alarm switch

£483.38

EACH

Datasheet
3VA1112-3EF36-0JH0
3VA1112-3EF36-0JH0
3VA1112-3EF36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£474.35

EACH

Datasheet
3VA1112-3EF36-0JC0
3VA1112-3EF36-0JC0
3VA1112-3EF36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£455.66

EACH

Datasheet
3VA1112-3EF36-0JA0
3VA1112-3EF36-0JA0
3VA1112-3EF36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£419.58

EACH

Datasheet
3VA1112-3FF42-0AA0
3VA1112-3FF42-0AA0
3VA1112-3FF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% nut keeper kit

£398.93

EACH

Datasheet
3VA1112-4FE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£362.97

EACH

Datasheet
3VA1112-4FE46-0AA0
3VA1112-4FE46-0AA0
3VA1112-4FE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£380.39

EACH

Datasheet
3VA1112-4FF42-0AA0
3VA1112-4FF42-0AA0
3VA1112-4FF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% nut keeper kit

£403.29

EACH

Datasheet
3VA1112-5EF36-0DA0
3VA1112-5EF36-0DA0
3VA1112-5EF36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£504.66

EACH

Datasheet
3VA1112-5EF36-0CH0
3VA1112-5EF36-0CH0
3VA1112-5EF36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-5EF36-0CC0
3VA1112-5EF36-0CC0
3VA1112-5EF36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-5EF36-0CA0
3VA1112-5EF36-0CA0
3VA1112-5EF36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£504.66

EACH

Datasheet
3VA1112-5EF36-0BH0
3VA1112-5EF36-0BH0
3VA1112-5EF36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-5EF36-0BC0
3VA1112-5EF36-0BC0
3VA1112-5EF36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-5EF36-0BA0
3VA1112-5EF36-0BA0
3VA1112-5EF36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC

£504.66

EACH

Datasheet
3VA1112-5EF36-0AH0
3VA1112-5EF36-0AH0
3VA1112-5EF36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£475.00

EACH

Datasheet
3VA1112-5EF36-0AG0
3VA1112-5EF36-0AG0
3VA1112-5EF36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£475.00

EACH

Datasheet
3VA1112-5EF36-0AF0
3VA1112-5EF36-0AF0
3VA1112-5EF36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£456.31

EACH

Datasheet
3VA1112-5EF36-0AE0
3VA1112-5EF36-0AE0
3VA1112-5EF36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 4 auxiliary switches HQ

£494.33

EACH

Datasheet
3VA1112-5EF36-0AD0
3VA1112-5EF36-0AD0
3VA1112-5EF36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 3 auxiliary switches HQ

£475.00

EACH

Datasheet
3VA1112-5EF36-0AC0
3VA1112-5EF36-0AC0
3VA1112-5EF36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ

£456.31

EACH

Datasheet
3VA1112-5EF36-0AB0
3VA1112-5EF36-0AB0
3VA1112-5EF36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HP

£475.00

EACH

Datasheet
3VA1112-5EF36-0AA0
3VA1112-5EF36-0AA0
3VA1112-5EF36-0AA0MCCB_IEC_FS160_125A_3P_55KA_TM_ ATAM

£330.33

EACH

Catalogue
Datasheet
3VA1112-5EF32-0KH0
3VA1112-5EF32-0KH0
3VA1112-5EF32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5EF32-0KC0
3VA1112-5EF32-0KC0
3VA1112-5EF32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-5EF32-0KA0
3VA1112-5EF32-0KA0
3VA1112-5EF32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£469.20

EACH

Datasheet
3VA1112-5EF32-0JH0
3VA1112-5EF32-0JH0
3VA1112-5EF32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5EF32-0JC0
3VA1112-5EF32-0JC0
3VA1112-5EF32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-5EF32-0JA0
3VA1112-5EF32-0JA0
3VA1112-5EF32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£469.20

EACH

Datasheet
3VA1112-5EF32-0HH0
3VA1112-5EF32-0HH0
3VA1112-5EF32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5EF32-0HF0
3VA1112-5EF32-0HF0
3VA1112-5EF32-0HF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut shunt trip left 24V AC 50/60Hz/24-30V DC accessory 1 auxiliary switch changeover H 1 trip alarm switch changeover

£504.00

EACH

Datasheet
3VA1112-5EF32-0HC0
3VA1112-5EF32-0HC0
3VA1112-5EF32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-5EF32-0HA0
3VA1112-5EF32-0HA0
3VA1112-5EF32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£469.20

EACH

Datasheet
3VA1112-5EF32-0DH0
3VA1112-5EF32-0DH0
3VA1112-5EF32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5EF32-0DC0
3VA1112-5EF32-0DC0
3VA1112-5EF32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5EF36-0DC0
3VA1112-5EF36-0DC0
3VA1112-5EF36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-5EF36-0DF0
3VA1112-5EF36-0DF0
3VA1112-5EF36-0DF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 1 auxiliary switch HQ 1 trip alarm switch HQ

£541.38

EACH

Datasheet
3VA1112-5EF36-0DH0
3VA1112-5EF36-0DH0
3VA1112-5EF36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-5EF36-0HA0
3VA1112-5EF36-0HA0
3VA1112-5EF36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£485.32

EACH

Datasheet
3VA1112-5MH32-0AD0
3VA1112-5MH32-0AD0
3VA1112-5MH32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 3 auxiliary switches HQ

£457.60

EACH

Datasheet
3VA1112-5MH32-0AC0
3VA1112-5MH32-0AC0
3VA1112-5MH32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HQ

£440.20

EACH

Datasheet
3VA1112-5MH32-0AB0
3VA1112-5MH32-0AB0
3VA1112-5MH32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HP

£457.60

EACH

Datasheet
3VA1112-5MH32-0AA0
3VA1112-5MH32-0AA0
3VA1112-5MH32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=7...16 x In nut keeper kit

£447.21

EACH

Datasheet
3VA1112-5GF42-0AA0
3VA1112-5GF42-0AA0
3VA1112-5GF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit

£439.37

EACH

Datasheet
3VA1112-5GE46-0AA0
3VA1112-5GE46-0AA0
3VA1112-5GE46-0AA0MCCB_IEC_FS160_125A_4P_55KA_TM_ ATFM

£445.53

EACH

Catalogue
Datasheet
3VA1112-5GE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£395.46

EACH

Datasheet
3VA1112-5GD46-0AA0
3VA1112-5GD46-0AA0
3VA1112-5GD46-0AA0MCCB_IEC_FS160_125A_4P_55KA_TM_ FTFM

£424.19

EACH

Catalogue
Datasheet
3VA1112-5GD42-0AA0
3VA1112-5GD42-0AA0
3VA1112-5GD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£375.67

EACH

Datasheet
3VA1112-5FF46-0AA0
3VA1112-5FF46-0AA0
3VA1112-5FF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% clamp connection

£456.81

EACH

Datasheet
3VA1112-5FF42-0AA0
3VA1112-5FF42-0AA0
3VA1112-5FF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% nut keeper kit

£439.37

EACH

Datasheet
3VA1112-5FE46-0AA0
3VA1112-5FE46-0AA0
3VA1112-5FE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£412.88

EACH

Datasheet
3VA1112-5EF32-0DA0
3VA1112-5EF32-0DA0
3VA1112-5EF32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£487.24

EACH

Datasheet
3VA1112-5FE42-0AA0
3VA1112-5FE42-0AA0
3VA1112-5FE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£395.46

EACH

Datasheet
3VA1112-5FD42-0AA0
3VA1112-5FD42-0AA0
3VA1112-5FD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£375.67

EACH

Datasheet
3VA1112-5EF46-0DC0
3VA1112-5EF46-0DC0
3VA1112-5EF46-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection circuit breaker 3VA1 IEC frame 160 undervoltage release 208-230V AC 50/60Hz 2 auxiliary switches HQ

£704.88

EACH

Datasheet
3VA1112-5EF46-0AA0
3VA1112-5EF46-0AA0
3VA1112-5EF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

£469.24

EACH

Datasheet
3VA1112-5EF42-0DC0
3VA1112-5EF42-0DC0
3VA1112-5EF42-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit circuit breaker 3VA1 IEC frame 160 undervoltage release 208-230V AC 50/60Hz 2 auxiliary switches HQ

£677.77

EACH

Datasheet
3VA1112-5EF42-0AA0
3VA1112-5EF42-0AA0
3VA1112-5EF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

£451.81

EACH

Datasheet
3VA1112-5EF36-0KH0
3VA1112-5EF36-0KH0
3VA1112-5EF36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5EF36-0KC0
3VA1112-5EF36-0KC0
3VA1112-5EF36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5EF36-0KA0
3VA1112-5EF36-0KA0
3VA1112-5EF36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC

£485.32

EACH

Datasheet
3VA1112-5EF36-0JH0
3VA1112-5EF36-0JH0
3VA1112-5EF36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5EF36-0JC0
3VA1112-5EF36-0JC0
3VA1112-5EF36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5EF36-0JA0
3VA1112-5EF36-0JA0
3VA1112-5EF36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£485.32

EACH

Datasheet
3VA1112-5EF36-0HH0
3VA1112-5EF36-0HH0
3VA1112-5EF36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5EF36-0HC0
3VA1112-5EF36-0HC0
3VA1112-5EF36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5FD46-0AA0
3VA1112-5FD46-0AA0
3VA1112-5FD46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£393.10

EACH

Datasheet
3VA1112-5EF32-0CH0
3VA1112-5EF32-0CH0
3VA1112-5EF32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5EF32-0CC0
3VA1112-5EF32-0CC0
3VA1112-5EF32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5EF32-0CA0
3VA1112-5EF32-0CA0
3VA1112-5EF32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£487.24

EACH

Datasheet
3VA1112-5ED32-0DC0
3VA1112-5ED32-0DC0
3VA1112-5ED32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£496.27

EACH

Datasheet
3VA1112-5ED32-0DA0
3VA1112-5ED32-0DA0
3VA1112-5ED32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£459.53

EACH

Datasheet
3VA1112-5ED32-0CH0
3VA1112-5ED32-0CH0
3VA1112-5ED32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£514.32

EACH

Datasheet
3VA1112-5ED32-0CC0
3VA1112-5ED32-0CC0
3VA1112-5ED32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£496.27

EACH

Datasheet
3VA1112-5ED32-0CA0
3VA1112-5ED32-0CA0
3VA1112-5ED32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£459.53

EACH

Datasheet
3VA1112-5ED32-0BH0
3VA1112-5ED32-0BH0
3VA1112-5ED32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£514.32

EACH

Datasheet
3VA1112-5ED32-0BC0
3VA1112-5ED32-0BC0
3VA1112-5ED32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£496.27

EACH

Datasheet
3VA1112-5ED32-0BA0
3VA1112-5ED32-0BA0
3VA1112-5ED32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 24V DC

£459.53

EACH

Datasheet
3VA1112-5ED32-0AH0
3VA1112-5ED32-0AH0
3VA1112-5ED32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£428.59

EACH

Datasheet
3VA1112-5ED32-0AG0
3VA1112-5ED32-0AG0
3VA1112-5ED32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£428.59

EACH

Datasheet
3VA1112-5ED32-0AF0
3VA1112-5ED32-0AF0
3VA1112-5ED32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£410.54

EACH

Datasheet
3VA1112-5ED32-0AE0
3VA1112-5ED32-0AE0
3VA1112-5ED32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 4 auxiliary switches HQ

£447.28

EACH

Datasheet
3VA1112-5ED32-0AD0
3VA1112-5ED32-0AD0
3VA1112-5ED32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 3 auxiliary switches HQ

£428.59

EACH

Datasheet
3VA1112-5ED32-0DH0
3VA1112-5ED32-0DH0
3VA1112-5ED32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£514.32

EACH

Datasheet
3VA1112-5ED32-0AC0
3VA1112-5ED32-0AC0
3VA1112-5ED32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 2 auxiliary switches HQ

£410.54

EACH

Datasheet
3VA1112-5ED32-0AA0
3VA1112-5ED32-0AA0
3VA1112-5ED32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£249.68

EACH

Datasheet
3VA1112-5ED26-0AA0
3VA1112-5ED26-0AA0
3VA1112-5ED26-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection

£296.09

EACH

Datasheet
3VA1112-5ED22-0AA0
3VA1112-5ED22-0AA0
3VA1112-5ED22-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£285.37

EACH

Datasheet
3VA1112-5ED16-0AA0
3VA1112-5ED16-0AA0
3VA1112-5ED16-0AA0MCCB_IEC_FS160_125A_1P_55KA_TM_ FTFM

£177.45

EACH

Catalogue
Datasheet
3VA1112-5ED12-0AA0
3VA1112-5ED12-0AA0
3VA1112-5ED12-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 240V 1-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£157.89

EACH

Datasheet
3VA1112-4GF46-0AA0
3VA1112-4GF46-0AA0
3VA1112-4GF46-0AA0MCCB_IEC_FS160_125A_4P_36KA_TM_ ATAM

£454.03

EACH

Catalogue
Datasheet
3VA1112-4GF42-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit UNDERVOLTAGE RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up

£560.91

EACH

Datasheet
3VA1112-4GF42-0AA0
3VA1112-4GF42-0AA0
3VA1112-4GF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit

£403.29

EACH

Datasheet
3VA1112-4GE46-0AA0
3VA1112-4GE46-0AA0
3VA1112-4GE46-0AA0MCCB_IEC_FS160_125A_4P_36KA_TM_ ATFM

£410.47

EACH

Catalogue
Datasheet
3VA1112-4GE42-0AA0
3VA1112-4GE42-0AA0
3VA1112-4GE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£362.97

EACH

Datasheet
3VA1112-4GD46-0AA0
3VA1112-4GD46-0AA0
3VA1112-4GD46-0AA0MCCB_IEC_FS160_125A_4P_36KA_TM_ FTFM

£390.87

EACH

Catalogue
Datasheet
3VA1112-4GD42-0AA0
3VA1112-4GD42-0AA0
3VA1112-4GD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£344.81

EACH

Datasheet
3VA1112-4FF46-0AA0
3VA1112-4FF46-0AA0
3VA1112-4FF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% clamp connection

£420.75

EACH

Datasheet
3VA1112-5ED32-0AB0
3VA1112-5ED32-0AB0
3VA1112-5ED32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit 2 auxiliary switches HP

£428.59

EACH

Datasheet
3VA1112-3EF32-0DA0
3VA1112-3EF32-0DA0
3VA1112-3EF32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£421.50

EACH

Datasheet
3VA1112-5ED32-0HA0
3VA1112-5ED32-0HA0
3VA1112-5ED32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£440.83

EACH

Datasheet
3VA1112-5ED32-0HH0
3VA1112-5ED32-0HH0
3VA1112-5ED32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£495.61

EACH

Datasheet
3VA1112-5EF32-0BH0
3VA1112-5EF32-0BH0
3VA1112-5EF32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5EF32-0BC0
3VA1112-5EF32-0BC0
3VA1112-5EF32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5EF32-0BA0
3VA1112-5EF32-0BA0
3VA1112-5EF32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£487.24

EACH

Datasheet
3VA1112-5EF32-0AH0
3VA1112-5EF32-0AH0
3VA1112-5EF32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£457.60

EACH

Datasheet
3VA1112-5EF32-0AG0
3VA1112-5EF32-0AG0
3VA1112-5EF32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£457.60

EACH

Datasheet
3VA1112-5EF32-0AF0
3VA1112-5EF32-0AF0
3VA1112-5EF32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£440.20

EACH

Datasheet
3VA1112-5EF32-0AE0
3VA1112-5EF32-0AE0
3VA1112-5EF32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 4 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-5EF32-0AD0
3VA1112-5EF32-0AD0
3VA1112-5EF32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 3 auxiliary switches HQ

£457.60

EACH

Datasheet
3VA1112-5EF32-0AC0
3VA1112-5EF32-0AC0
3VA1112-5EF32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ

£440.20

EACH

Datasheet
3VA1112-5EF32-0AB0
3VA1112-5EF32-0AB0
3VA1112-5EF32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HP

£457.60

EACH

Datasheet
3VA1112-5EF32-0AA0
3VA1112-5EF32-0AA0
3VA1112-5EF32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit

£300.78

EACH

Datasheet
3VA1112-5EE46-0AA0
3VA1112-5EE46-0AA0
3VA1112-5EE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£446.48

EACH

Datasheet
3VA1112-5EE42-0AA0
3VA1112-5EE42-0AA0
3VA1112-5EE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£429.06

EACH

Datasheet
3VA1112-5ED32-0HC0
3VA1112-5ED32-0HC0
3VA1112-5ED32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-5EE36-0HC0
3VA1112-5EE36-0HC0
3VA1112-5EE36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp connection circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp SHUNT TRIP LEFT 24 V AC 50/60 HZ / 24-30 V DC ACCESSORY FOR 2 AUXILIARY SWITCH CHANGEOVER H

£500.78

EACH

Datasheet
3VA1112-5EE36-0AA0
3VA1112-5EE36-0AA0
3VA1112-5EE36-0AA0MCCB_IEC_FS160_125A_3P_55KA_TM_ ATFM

£298.80

EACH

Catalogue
Datasheet
3VA1112-5EE32-0LC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut UNIVERSAL RELEASE 24 V DC ACCESSORY FOR 3VA1 and 3VA20 up 2 AUXILIARY SWITCH CHANGEOVER H

£569.74

EACH

Datasheet
3VA1112-5EE32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit

£270.70

EACH

Datasheet
3VA1112-5ED46-0AA0
3VA1112-5ED46-0AA0
3VA1112-5ED46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£437.55

EACH

Datasheet
3VA1112-5ED42-0AA0
3VA1112-5ED42-0AA0
3VA1112-5ED42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£420.12

EACH

Datasheet
3VA1112-5ED36-0AC0
3VA1112-5ED36-0AC0
3VA1112-5ED36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection 2 AUXILIARY SWITCH CHANGEOVER H

£427.31

EACH

Datasheet
3VA1112-5ED36-0AA0
3VA1112-5ED36-0AA0
3VA1112-5ED36-0AA0MCCB_IEC_FS160_125A_3P_55KA_TM_ FTFM

£284.61

EACH

Catalogue
Datasheet
3VA1112-5ED32-0KH0
3VA1112-5ED32-0KH0
3VA1112-5ED32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£495.61

EACH

Datasheet
3VA1112-5ED32-0KC0
3VA1112-5ED32-0KC0
3VA1112-5ED32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-5ED32-0KA0
3VA1112-5ED32-0KA0
3VA1112-5ED32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£440.83

EACH

Datasheet
3VA1112-5ED32-0JH0
3VA1112-5ED32-0JH0
3VA1112-5ED32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£495.61

EACH

Datasheet
3VA1112-5ED32-0JC0
3VA1112-5ED32-0JC0
3VA1112-5ED32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-5ED32-0JA0
3VA1112-5ED32-0JA0
3VA1112-5ED32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£440.83

EACH

Datasheet
3VA1112-5EE36-0AC0
3VA1112-5EE36-0AC0
3VA1112-5EE36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp connection circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp 2 AUXILIARY SWITCH CHANGEOVER H

£436.33

EACH

Datasheet
3VA1112-3EF32-0CH0
3VA1112-3EF32-0CH0
3VA1112-3EF32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£476.28

EACH

Datasheet
3VA1112-3EF32-0CC0
3VA1112-3EF32-0CC0
3VA1112-3EF32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£457.60

EACH

Datasheet
3VA1112-3EF32-0CA0
3VA1112-3EF32-0CA0
3VA1112-3EF32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£421.50

EACH

Datasheet
3VA1112-5MH32-0AE0
3VA1112-5MH32-0AE0
3VA1112-5MH32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 4 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-1AA42-0HH0
3VA1112-1AA42-0HH0
3VA1112-1AA42-0HH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£406.69

EACH

Datasheet
3VA1112-3EE36-0AA0
3VA1112-3EE36-0AA0
3VA1112-3EE36-0AA0MCCB_IEC_FS160_125A_3P_25KA_TM_ ATFM

£265.25

EACH

Catalogue
Datasheet
3VA1112-3GE46-0AA0
3VA1112-3GE46-0AA0
3VA1112-3GE46-0AA0MCCB_IEC_FS160_125A_4P_25KA_TM_ ATFM

£392.08

EACH

Catalogue
Datasheet
3VA1112-5GF46-0AA0
3VA1112-5GF46-0AA0
3VA1112-5GF46-0AA0MCCB_IEC_FS160_125A_4P_55KA_TM_ ATAM

£492.94

EACH

Catalogue
Datasheet
3VA1112-1AA42-0HC0
3VA1112-1AA42-0HC0
3VA1112-1AA42-0HC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£388.64

EACH

Datasheet
3VA1112-1AA42-0HA0
3VA1112-1AA42-0HA0
3VA1112-1AA42-0HA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz

£351.25

EACH

Datasheet
3VA1112-1AA42-0DH0
3VA1112-1AA42-0DH0
3VA1112-1AA42-0DH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£424.72

EACH

Datasheet
3VA1112-1AA42-0DD0
3VA1112-1AA42-0DD0
3VA1112-1AA42-0DD0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release 208-230V AC 50/60Hz 3 auxiliary switches HQ

£426.66

EACH

Datasheet
3VA1112-1AA42-0DC0
3VA1112-1AA42-0DC0
3VA1112-1AA42-0DC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£407.32

EACH

Datasheet
3VA1112-1AA42-0DA0
3VA1112-1AA42-0DA0
3VA1112-1AA42-0DA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£370.59

EACH

Datasheet
3VA1112-1AA42-0CH0
3VA1112-1AA42-0CH0
3VA1112-1AA42-0CH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£424.72

EACH

Datasheet
3VA1112-1AA42-0CC0
3VA1112-1AA42-0CC0
3VA1112-1AA42-0CC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£407.32

EACH

Datasheet
3VA1112-1AA42-0CA0
3VA1112-1AA42-0CA0
3VA1112-1AA42-0CA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£370.59

EACH

Datasheet
3VA1112-1AA42-0BH0
3VA1112-1AA42-0BH0
3VA1112-1AA42-0BH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£424.72

EACH

Datasheet
3VA1112-1AA42-0BC0
3VA1112-1AA42-0BC0
3VA1112-1AA42-0BC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£407.32

EACH

Datasheet
3VA1112-1AA42-0BA0
3VA1112-1AA42-0BA0
3VA1112-1AA42-0BA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC

£370.59

EACH

Datasheet
3VA1112-1AA42-0AH0
3VA1112-1AA42-0AH0
3VA1112-1AA42-0AH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£340.94

EACH

Datasheet
3VA1112-1AA42-0AG0
3VA1112-1AA42-0AG0
3VA1112-1AA42-0AG0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£340.94

EACH

Datasheet
3VA1112-1AA42-0AF0
3VA1112-1AA42-0AF0
3VA1112-1AA42-0AF0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£322.25

EACH

Datasheet
3VA1112-1AA42-0AE0
3VA1112-1AA42-0AE0
3VA1112-1AA42-0AE0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 4 auxiliary switches HQ

£359.64

EACH

Datasheet
3VA1112-1AA42-0AD0
3VA1112-1AA42-0AD0
3VA1112-1AA42-0AD0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 3 auxiliary switches HQ

£340.94

EACH

Datasheet
3VA1112-1AA42-0AC0
3VA1112-1AA42-0AC0
3VA1112-1AA42-0AC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HQ

£322.25

EACH

Datasheet
3VA1112-1AA42-0AB0
3VA1112-1AA42-0AB0
3VA1112-1AA42-0AB0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HP

£340.94

EACH

Datasheet
3VA1112-1AA42-0AA0
3VA1112-1AA42-0AA0
3VA1112-1AA42-0AA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit

£295.21

EACH

Datasheet
3VA1112-1AA36-0KH0
3VA1112-1AA36-0KH0
3VA1112-1AA36-0KH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£357.05

EACH

Datasheet
3VA1112-1AA36-0KC0
3VA1112-1AA36-0KC0
3VA1112-1AA36-0KC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£338.36

EACH

Datasheet
3VA1112-1AA36-0KA0
3VA1112-1AA36-0KA0
3VA1112-1AA36-0KA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 220-250V DC; 208-277V AC

£301.62

EACH

Datasheet
3VA1112-1AA36-0JH0
3VA1112-1AA36-0JH0
3VA1112-1AA36-0JH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£357.05

EACH

Datasheet
3VA1112-1AA36-0JC0
3VA1112-1AA36-0JC0
3VA1112-1AA36-0JC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£338.36

EACH

Datasheet
3VA1112-1AA36-0JA0
3VA1112-1AA36-0JA0
3VA1112-1AA36-0JA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£301.62

EACH

Datasheet
3VA1112-1AA42-0JA0
3VA1112-1AA42-0JA0
3VA1112-1AA42-0JA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£351.25

EACH

Datasheet
3VA1112-1AA42-0JC0
3VA1112-1AA42-0JC0
3VA1112-1AA42-0JC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£388.64

EACH

Datasheet
3VA1112-1AA42-0JH0
3VA1112-1AA42-0JH0
3VA1112-1AA42-0JH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£406.69

EACH

Datasheet
3VA1112-1AA42-0KA0
3VA1112-1AA42-0KA0
3VA1112-1AA42-0KA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£351.25

EACH

Datasheet
3VA1112-3EF32-0BH0
3VA1112-3EF32-0BH0
3VA1112-3EF32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£476.28

EACH

Datasheet
3VA1112-3EF32-0BC0
3VA1112-3EF32-0BC0
3VA1112-3EF32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£457.60

EACH

Datasheet
3VA1112-3EF32-0BA0
3VA1112-3EF32-0BA0
3VA1112-3EF32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£421.50

EACH

Datasheet
3VA1112-3EF32-0AH0
3VA1112-3EF32-0AH0
3VA1112-3EF32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£391.86

EACH

Datasheet
3VA1112-3EF32-0AG0
3VA1112-3EF32-0AG0
3VA1112-3EF32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£391.86

EACH

Datasheet
3VA1112-3EF32-0AF0
3VA1112-3EF32-0AF0
3VA1112-3EF32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£373.16

EACH

Datasheet
3VA1112-3EF32-0AE0
3VA1112-3EF32-0AE0
3VA1112-3EF32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 4 auxiliary switches HQ

£409.91

EACH

Datasheet
3VA1112-3EF32-0AD0
3VA1112-3EF32-0AD0
3VA1112-3EF32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 3 auxiliary switches HQ

£391.86

EACH

Datasheet
3VA1112-3EF32-0AC0
3VA1112-3EF32-0AC0
3VA1112-3EF32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ

£373.16

EACH

Datasheet
3VA1112-3EF32-0AB0
3VA1112-3EF32-0AB0
3VA1112-3EF32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HP

£391.86

EACH

Datasheet
3VA1112-3EF32-0AA0
3VA1112-3EF32-0AA0
3VA1112-3EF32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit

£291.18

EACH

Datasheet
3VA1112-3EE46-0AA0
3VA1112-3EE46-0AA0
3VA1112-3EE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£387.97

EACH

Datasheet
3VA1112-3EE42-0AA0
3VA1112-3EE42-0AA0
3VA1112-3EE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£370.55

EACH

Datasheet
3VA1112-1AA36-0HH0
3VA1112-1AA36-0HH0
3VA1112-1AA36-0HH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£357.05

EACH

Datasheet
3VA1112-3ED46-0AA0
3VA1112-3ED46-0AA0
3VA1112-3ED46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£391.66

EACH

Datasheet
3VA1112-3ED42-0AA0
3VA1112-3ED42-0AA0
3VA1112-3ED42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£373.71

EACH

Datasheet
3VA1112-3ED36-0AA0
3VA1112-3ED36-0AA0
3VA1112-3ED36-0AA0MCCB_IEC_FS160_125A_3P_25KA_TM_ FTFM

£252.78

EACH

Catalogue
Datasheet
3VA1112-3ED32-0AA0
3VA1112-3ED32-0AA0
3VA1112-3ED32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£213.37

EACH

Datasheet
3VA1112-3ED26-0AA0
3VA1112-3ED26-0AA0
3VA1112-3ED26-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection

£259.90

EACH

Datasheet
3VA1112-3ED22-0AA0
3VA1112-3ED22-0AA0
3VA1112-3ED22-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£247.40

EACH

Datasheet
3VA1112-3ED16-0AA0
3VA1112-3ED16-0AA0
3VA1112-3ED16-0AA0MCCB_IEC_FS160_125A_1P_25KA_TM_ FTFM

£121.27

EACH

Catalogue
Datasheet
3VA1112-3ED12-0AA0
3VA1112-3ED12-0AA0
3VA1112-3ED12-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 240V 1-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£112.39

EACH

Datasheet
3VA1112-1AA46-0AC0
3VA1112-1AA46-0AC0
3VA1112-1AA46-0AC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 2 auxiliary switches HQ

£346.09

EACH

Datasheet
3VA1112-1AA46-0AA0
3VA1112-1AA46-0AA0
3VA1112-1AA46-0AA0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection

£312.63

EACH

Datasheet
3VA1112-1AA42-0KH0
3VA1112-1AA42-0KH0
3VA1112-1AA42-0KH0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£406.69

EACH

Datasheet
3VA1112-1AA42-0KD0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit SHUNT TRIP LEFT 208-277 V AC 50/60 HZ 220-250 V DC ACCESSORY 3 AUXILIARY SWITCH CHANGEOVER H

£406.69

EACH

Datasheet
3VA1112-1AA42-0KC0
3VA1112-1AA42-0KC0
3VA1112-1AA42-0KC0switch disconnector 3VA1 IEC frame 160 4-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£388.64

EACH

Datasheet
3VA1112-3EE32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit

£231.32

EACH

Datasheet
3VA1112-1AA36-0HC0
3VA1112-1AA36-0HC0
3VA1112-1AA36-0HC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£338.36

EACH

Datasheet
3VA1112-1AA36-0HA0
3VA1112-1AA36-0HA0
3VA1112-1AA36-0HA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz

£301.62

EACH

Datasheet
3VA1112-1AA36-0DH0
3VA1112-1AA36-0DH0
3VA1112-1AA36-0DH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£376.37

EACH

Datasheet
3VA1112-1AA32-0BH0
3VA1112-1AA32-0BH0
3VA1112-1AA32-0BH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£359.64

EACH

Datasheet
3VA1112-1AA32-0BC0
3VA1112-1AA32-0BC0
3VA1112-1AA32-0BC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£340.94

EACH

Datasheet
3VA1112-1AA32-0BA0
3VA1112-1AA32-0BA0
3VA1112-1AA32-0BA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 24V DC

£304.20

EACH

Datasheet
3VA1112-1AA32-0AH0
3VA1112-1AA32-0AH0
3VA1112-1AA32-0AH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£274.56

EACH

Datasheet
3VA1112-1AA32-0AG0
3VA1112-1AA32-0AG0
3VA1112-1AA32-0AG0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£274.56

EACH

Datasheet
3VA1112-1AA32-0AF0
3VA1112-1AA32-0AF0
3VA1112-1AA32-0AF0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£256.51

EACH

Datasheet
3VA1112-1AA32-0AE0
3VA1112-1AA32-0AE0
3VA1112-1AA32-0AE0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 4 auxiliary switches HQ

£293.25

EACH

Datasheet
3VA1112-1AA32-0AD0
3VA1112-1AA32-0AD0
3VA1112-1AA32-0AD0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 3 auxiliary switches HQ

£274.56

EACH

Datasheet
3VA1112-1AA32-0AC0
3VA1112-1AA32-0AC0
3VA1112-1AA32-0AC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HQ

£256.51

EACH

Datasheet
3VA1112-1AA32-0AB0
3VA1112-1AA32-0AB0
3VA1112-1AA32-0AB0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit 2 auxiliary switches HP

£274.56

EACH

Datasheet
3VA1112-1AA32-0AA0
3VA1112-1AA32-0AA0
3VA1112-1AA32-0AA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit

£226.59

EACH

Datasheet
3VA1112-1AA32-0CA0
3VA1112-1AA32-0CA0
3VA1112-1AA32-0CA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£304.20

EACH

Datasheet
3VA1112-1AA32-0CC0
3VA1112-1AA32-0CC0
3VA1112-1AA32-0CC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£340.94

EACH

Datasheet
3VA1112-1AA32-0DA0
3VA1112-1AA32-0DA0
3VA1112-1AA32-0DA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£304.20

EACH

Datasheet
3VA1112-1AA36-0DF0
3VA1112-1AA36-0DF0
3VA1112-1AA36-0DF0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 1 AUXILIARY SWITCH CHANGEOVER H 1 TRIP ALARM SWITCH CHANGEOVER

£358.84

EACH

Datasheet
3VA1112-1AA36-0DC0
3VA1112-1AA36-0DC0
3VA1112-1AA36-0DC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£357.70

EACH

Datasheet
3VA1112-1AA36-0DA0
3VA1112-1AA36-0DA0
3VA1112-1AA36-0DA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£321.60

EACH

Datasheet
3VA1112-1AA36-0CH0
3VA1112-1AA36-0CH0
3VA1112-1AA36-0CH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£376.37

EACH

Datasheet
3VA1112-1AA36-0CC0
3VA1112-1AA36-0CC0
3VA1112-1AA36-0CC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£357.70

EACH

Datasheet
3VA1112-1AA36-0CA0
3VA1112-1AA36-0CA0
3VA1112-1AA36-0CA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£321.60

EACH

Datasheet
3VA1112-1AA36-0BH0
3VA1112-1AA36-0BH0
3VA1112-1AA36-0BH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£376.37

EACH

Datasheet
3VA1112-1AA36-0BC0
3VA1112-1AA36-0BC0
3VA1112-1AA36-0BC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£357.70

EACH

Datasheet
3VA1112-1AA36-0BA0
3VA1112-1AA36-0BA0
3VA1112-1AA36-0BA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection undervoltage release (UVR) 24V DC

£321.60

EACH

Datasheet
3VA1112-1AA36-0AH0
3VA1112-1AA36-0AH0
3VA1112-1AA36-0AH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£291.32

EACH

Datasheet
3VA1112-1AA36-0AG0
3VA1112-1AA36-0AG0
3VA1112-1AA36-0AG0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£291.32

EACH

Datasheet
3VA1112-1AA36-0AF0
3VA1112-1AA36-0AF0
3VA1112-1AA36-0AF0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£273.27

EACH

Datasheet
3VA1112-1AA36-0AE0
3VA1112-1AA36-0AE0
3VA1112-1AA36-0AE0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 4 auxiliary switches HQ

£310.01

EACH

Datasheet
3VA1112-1AA32-0CH0
3VA1112-1AA32-0CH0
3VA1112-1AA32-0CH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£359.64

EACH

Datasheet
3VA1112-1AA36-0AD0
3VA1112-1AA36-0AD0
3VA1112-1AA36-0AD0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 3 auxiliary switches HQ

£291.32

EACH

Datasheet
3VA1112-1AA36-0AB0
3VA1112-1AA36-0AB0
3VA1112-1AA36-0AB0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 2 auxiliary switches HP

£291.32

EACH

Datasheet
3VA1112-1AA36-0AA0
3VA1112-1AA36-0AA0
3VA1112-1AA36-0AA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection

£240.67

EACH

Datasheet
3VA1112-1AA32-0KH0
3VA1112-1AA32-0KH0
3VA1112-1AA32-0KH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£339.65

EACH

Datasheet
3VA1112-1AA32-0KC0
3VA1112-1AA32-0KC0
3VA1112-1AA32-0KC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC 2 auxiliary switches HQ

£321.60

EACH

Datasheet
3VA1112-1AA32-0KA0
3VA1112-1AA32-0KA0
3VA1112-1AA32-0KA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 220-250V DC; 208-277V AC

£286.16

EACH

Datasheet
3VA1112-1AA32-0JH0
3VA1112-1AA32-0JH0
3VA1112-1AA32-0JH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£339.65

EACH

Datasheet
3VA1112-1AA32-0JC0
3VA1112-1AA32-0JC0
3VA1112-1AA32-0JC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£321.60

EACH

Datasheet
3VA1112-1AA32-0JA0
3VA1112-1AA32-0JA0
3VA1112-1AA32-0JA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£286.16

EACH

Datasheet
3VA1112-1AA32-0HH0
3VA1112-1AA32-0HH0
3VA1112-1AA32-0HH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£339.65

EACH

Datasheet
3VA1112-1AA32-0HC0
3VA1112-1AA32-0HC0
3VA1112-1AA32-0HC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£321.60

EACH

Datasheet
3VA1112-1AA32-0HA0
3VA1112-1AA32-0HA0
3VA1112-1AA32-0HA0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit shunt trip (STL) 12-30V DC; 24 V AC 50/60 Hz

£286.16

EACH

Datasheet
3VA1112-1AA32-0DH0
3VA1112-1AA32-0DH0
3VA1112-1AA32-0DH0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£359.64

EACH

Datasheet
3VA1112-1AA32-0DC0
3VA1112-1AA32-0DC0
3VA1112-1AA32-0DC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£340.94

EACH

Datasheet
3VA1112-1AA36-0AC0
3VA1112-1AA36-0AC0
3VA1112-1AA36-0AC0switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=125A without overload protection w/o short-circuit protection clamp connection 2 auxiliary switches HQ

£273.27

EACH

Datasheet
3VA1112-5MH32-0AF0
3VA1112-5MH32-0AF0
3VA1112-5MH32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£440.20

EACH

Datasheet
3VA1112-5MH32-0AG0
3VA1112-5MH32-0AG0
3VA1112-5MH32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£457.60

EACH

Datasheet
3VA1112-5MH32-0AH0
3VA1112-5MH32-0AH0
3VA1112-5MH32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£457.60

EACH

Datasheet
3VA1112-6EF36-0CA0
3VA1112-6EF36-0CA0
3VA1112-6EF36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£541.38

EACH

Datasheet
3VA1112-6EF36-0BH0
3VA1112-6EF36-0BH0
3VA1112-6EF36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
3VA1112-6EF36-0BC0
3VA1112-6EF36-0BC0
3VA1112-6EF36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6EF36-0BA0
3VA1112-6EF36-0BA0
3VA1112-6EF36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 24V DC

£541.38

EACH

Datasheet
3VA1112-6EF36-0AH0
3VA1112-6EF36-0AH0
3VA1112-6EF36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£511.73

EACH

Datasheet
3VA1112-6EF36-0AG0
3VA1112-6EF36-0AG0
3VA1112-6EF36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£511.73

EACH

Datasheet
3VA1112-6EF36-0AF0
3VA1112-6EF36-0AF0
3VA1112-6EF36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£494.33

EACH

Datasheet
3VA1112-6EF36-0AE0
3VA1112-6EF36-0AE0
3VA1112-6EF36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 4 auxiliary switches HQ

£530.43

EACH

Datasheet
3VA1112-6EF36-0AD0
3VA1112-6EF36-0AD0
3VA1112-6EF36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 3 auxiliary switches HQ

£511.73

EACH

Datasheet
3VA1112-6EF36-0AC0
3VA1112-6EF36-0AC0
3VA1112-6EF36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HQ

£494.33

EACH

Datasheet
3VA1112-6EF36-0AB0
3VA1112-6EF36-0AB0
3VA1112-6EF36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection 2 auxiliary switches HP

£511.73

EACH

Datasheet
3VA1112-6EF36-0AA0
3VA1112-6EF36-0AA0
3VA1112-6EF36-0AA0MCCB_IEC_FS160_125A_3P_70KA_TM_ ATAM

£365.32

EACH

Catalogue
Datasheet
3VA1112-6EF32-0KH0
3VA1112-6EF32-0KH0
3VA1112-6EF32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6EF32-0KC0
3VA1112-6EF32-0KC0
3VA1112-6EF32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6EF32-0KA0
3VA1112-6EF32-0KA0
3VA1112-6EF32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC

£505.94

EACH

Datasheet
3VA1112-6EF32-0JH0
3VA1112-6EF32-0JH0
3VA1112-6EF32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6EF32-0JC0
3VA1112-6EF32-0JC0
3VA1112-6EF32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6EF32-0JA0
3VA1112-6EF32-0JA0
3VA1112-6EF32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£505.94

EACH

Datasheet
3VA1112-6EF32-0HH0
3VA1112-6EF32-0HH0
3VA1112-6EF32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6EF32-0HC0
3VA1112-6EF32-0HC0
3VA1112-6EF32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6EF32-0HA0
3VA1112-6EF32-0HA0
3VA1112-6EF32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£505.94

EACH

Datasheet
3VA1112-6EF32-0DH0
3VA1112-6EF32-0DH0
3VA1112-6EF32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6EF32-0DC0
3VA1112-6EF32-0DC0
3VA1112-6EF32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6EF32-0DA0
3VA1112-6EF32-0DA0
3VA1112-6EF32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£524.62

EACH

Datasheet
3VA1112-6EF32-0CH0
3VA1112-6EF32-0CH0
3VA1112-6EF32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6EF32-0CC0
3VA1112-6EF32-0CC0
3VA1112-6EF32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6EF32-0CA0
3VA1112-6EF32-0CA0
3VA1112-6EF32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£524.62

EACH

Datasheet
3VA1112-6EF36-0CC0
3VA1112-6EF36-0CC0
3VA1112-6EF36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6EF36-0CH0
3VA1112-6EF36-0CH0
3VA1112-6EF36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
3VA1112-6EF36-0DA0
3VA1112-6EF36-0DA0
3VA1112-6EF36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£541.38

EACH

Datasheet
3VA1112-6EF36-0DC0
3VA1112-6EF36-0DC0
3VA1112-6EF36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6MH32-0AC0
3VA1112-6MH32-0AC0
3VA1112-6MH32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-6MH32-0AB0
3VA1112-6MH32-0AB0
3VA1112-6MH32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HP

£495.61

EACH

Datasheet
3VA1112-6MH32-0AA0
3VA1112-6MH32-0AA0
3VA1112-6MH32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=7...16 x In nut keeper kit

£484.99

EACH

Datasheet
3VA1112-6GF46-0KF0
3VA1112-6GF46-0KF0
3VA1112-6GF46-0KF0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% clamp connection shunt trip (STL) 220-250V DC; 208-277V AC 1 auxiliary switch HQ 1 trip alarm switch HQ

£696.06

EACH

Datasheet
3VA1112-6GF46-0AA0
3VA1112-6GF46-0AA0
3VA1112-6GF46-0AA0MCCB_IEC_FS160_125A_4P_70KA_TM_ ATAM

£545.62

EACH

Catalogue
Datasheet
3VA1112-6GF42-0AA0
3VA1112-6GF42-0AA0
3VA1112-6GF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit

£488.20

EACH

Datasheet
3VA1112-6GE46-0AA0
3VA1112-6GE46-0AA0
3VA1112-6GE46-0AA0MCCB_IEC_FS160_125A_4P_70KA_TM_ ATFM

£492.94

EACH

Catalogue
Datasheet
3VA1112-6GE42-0AA0
3VA1112-6GE42-0AA0
3VA1112-6GE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£439.37

EACH

Datasheet
3VA1112-6GD46-0AA0
3VA1112-6GD46-0AA0
3VA1112-6GD46-0AA0MCCB_IEC_FS160_125A_4P_70KA_TM_ FTFM

£469.22

EACH

Catalogue
Datasheet
3VA1112-6GD42-0AA0
3VA1112-6GD42-0AA0
3VA1112-6GD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit

£417.41

EACH

Datasheet
3VA1112-6FF46-0AA0
3VA1112-6FF46-0AA0
3VA1112-6FF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% clamp connection

£505.63

EACH

Datasheet
3VA1112-6FF42-0AA0
3VA1112-6FF42-0AA0
3VA1112-6FF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor protection 50% nut keeper kit

£488.20

EACH

Datasheet
3VA1112-6FE46-0AA0
3VA1112-6FE46-0AA0
3VA1112-6FE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£456.81

EACH

Datasheet
3VA1112-6EF32-0BH0
3VA1112-6EF32-0BH0
3VA1112-6EF32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6FE42-0AA0
3VA1112-6FE42-0AA0
3VA1112-6FE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£439.37

EACH

Datasheet
3VA1112-6FD42-0AA0
3VA1112-6FD42-0AA0
3VA1112-6FD42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit

£417.41

EACH

Datasheet
3VA1112-6EF46-0AA0
3VA1112-6EF46-0AA0
3VA1112-6EF46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

£522.63

EACH

Datasheet
3VA1112-6EF42-0AA0
3VA1112-6EF42-0AA0
3VA1112-6EF42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

£505.21

EACH

Datasheet
3VA1112-6EF36-0KH0
3VA1112-6EF36-0KH0
3VA1112-6EF36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6EF36-0KC0
3VA1112-6EF36-0KC0
3VA1112-6EF36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6EF36-0KA0
3VA1112-6EF36-0KA0
3VA1112-6EF36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 220-250V DC, 208-277V AC

£522.05

EACH

Datasheet
3VA1112-6EF36-0JH0
3VA1112-6EF36-0JH0
3VA1112-6EF36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6EF36-0JC0
3VA1112-6EF36-0JC0
3VA1112-6EF36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6EF36-0JA0
3VA1112-6EF36-0JA0
3VA1112-6EF36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£522.05

EACH

Datasheet
3VA1112-6EF36-0HH0
3VA1112-6EF36-0HH0
3VA1112-6EF36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6EF36-0HC0
3VA1112-6EF36-0HC0
3VA1112-6EF36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6EF36-0HA0
3VA1112-6EF36-0HA0
3VA1112-6EF36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 12-30V DC, 24V AC 50/60Hz

£522.05

EACH

Datasheet
3VA1112-6EF36-0DH0
3VA1112-6EF36-0DH0
3VA1112-6EF36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
3VA1112-6FD46-0AA0
3VA1112-6FD46-0AA0
3VA1112-6FD46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor protection 50% clamp connection

£434.83

EACH

Datasheet
3VA1112-6EF32-0BC0
3VA1112-6EF32-0BC0
3VA1112-6EF32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6EF32-0BA0
3VA1112-6EF32-0BA0
3VA1112-6EF32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit undervoltage release (UVR) 24V DC

£524.62

EACH

Datasheet
3VA1112-6EF32-0AH0
3VA1112-6EF32-0AH0
3VA1112-6EF32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£495.61

EACH

Datasheet
3VA1112-5MH36-0BC0
3VA1112-5MH36-0BC0
3VA1112-5MH36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-5MH36-0BA0
3VA1112-5MH36-0BA0
3VA1112-5MH36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC

£504.66

EACH

Datasheet
3VA1112-5MH36-0AH0
3VA1112-5MH36-0AH0
3VA1112-5MH36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£475.00

EACH

Datasheet
3VA1112-5MH36-0AG0
3VA1112-5MH36-0AG0
3VA1112-5MH36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£475.00

EACH

Datasheet
3VA1112-5MH36-0AF0
3VA1112-5MH36-0AF0
3VA1112-5MH36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£456.31

EACH

Datasheet
3VA1112-5MH36-0AE0
3VA1112-5MH36-0AE0
3VA1112-5MH36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 4 auxiliary switches HQ

£494.33

EACH

Datasheet
3VA1112-5MH36-0AD0
3VA1112-5MH36-0AD0
3VA1112-5MH36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 3 auxiliary switches HQ

£475.00

EACH

Datasheet
3VA1112-5MH36-0AC0
3VA1112-5MH36-0AC0
3VA1112-5MH36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HQ

£456.31

EACH

Datasheet
3VA1112-5MH36-0AB0
3VA1112-5MH36-0AB0
3VA1112-5MH36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HP

£475.00

EACH

Datasheet
3VA1112-5MH36-0AA0
3VA1112-5MH36-0AA0
3VA1112-5MH36-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=7...16 x In clamp connection

£433.14

EACH

Datasheet
3VA1112-5MH32-0KH0
3VA1112-5MH32-0KH0
3VA1112-5MH32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5MH32-0KC0
3VA1112-5MH32-0KC0
3VA1112-5MH32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-5MH32-0KA0
3VA1112-5MH32-0KA0
3VA1112-5MH32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC

£469.20

EACH

Datasheet
3VA1112-5MH36-0BH0
3VA1112-5MH36-0BH0
3VA1112-5MH36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-5MH32-0JH0
3VA1112-5MH32-0JH0
3VA1112-5MH32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5MH32-0JA0
3VA1112-5MH32-0JA0
3VA1112-5MH32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£469.20

EACH

Datasheet
3VA1112-5MH32-0HH0
3VA1112-5MH32-0HH0
3VA1112-5MH32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£523.33

EACH

Datasheet
3VA1112-5MH32-0HC0
3VA1112-5MH32-0HC0
3VA1112-5MH32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-5MH32-0HA0
3VA1112-5MH32-0HA0
3VA1112-5MH32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz

£469.20

EACH

Datasheet
3VA1112-5MH32-0DH0
3VA1112-5MH32-0DH0
3VA1112-5MH32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5MH32-0DC0
3VA1112-5MH32-0DC0
3VA1112-5MH32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5MH32-0DA0
3VA1112-5MH32-0DA0
3VA1112-5MH32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£487.24

EACH

Datasheet
3VA1112-5MH32-0CH0
3VA1112-5MH32-0CH0
3VA1112-5MH32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5MH32-0CC0
3VA1112-5MH32-0CC0
3VA1112-5MH32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5MH32-0CA0
3VA1112-5MH32-0CA0
3VA1112-5MH32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£487.24

EACH

Datasheet
3VA1112-5MH32-0BH0
3VA1112-5MH32-0BH0
3VA1112-5MH32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£542.03

EACH

Datasheet
3VA1112-5MH32-0BC0
3VA1112-5MH32-0BC0
3VA1112-5MH32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£523.99

EACH

Datasheet
3VA1112-5MH32-0BA0
3VA1112-5MH32-0BA0
3VA1112-5MH32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC

£487.24

EACH

Datasheet
3VA1112-5MH32-0JC0
3VA1112-5MH32-0JC0
3VA1112-5MH32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£504.66

EACH

Datasheet
3VA1112-6MH32-0AD0
3VA1112-6MH32-0AD0
3VA1112-6MH32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 3 auxiliary switches HQ

£495.61

EACH

Datasheet
3VA1112-5MH36-0CA0
3VA1112-5MH36-0CA0
3VA1112-5MH36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£504.66

EACH

Datasheet
3VA1112-5MH36-0CH0
3VA1112-5MH36-0CH0
3VA1112-5MH36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-6EF32-0AG0
3VA1112-6EF32-0AG0
3VA1112-6EF32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£495.61

EACH

Datasheet
3VA1112-6EF32-0AF0
3VA1112-6EF32-0AF0
3VA1112-6EF32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£476.28

EACH

Datasheet
3VA1112-6EF32-0AE0
3VA1112-6EF32-0AE0
3VA1112-6EF32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 4 auxiliary switches HQ

£513.02

EACH

Datasheet
3VA1112-6EF32-0AD0
3VA1112-6EF32-0AD0
3VA1112-6EF32-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 3 auxiliary switches HQ

£495.61

EACH

Datasheet
3VA1112-6EF32-0AC0
3VA1112-6EF32-0AC0
3VA1112-6EF32-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HQ

£476.28

EACH

Datasheet
3VA1112-6EF32-0AB0
3VA1112-6EF32-0AB0
3VA1112-6EF32-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit 2 auxiliary switches HP

£495.61

EACH

Datasheet
3VA1112-6EF32-0AA0
3VA1112-6EF32-0AA0
3VA1112-6EF32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In nut keeper kit

£324.47

EACH

Datasheet
3VA1112-6EE46-0AA0
3VA1112-6EE46-0AA0
3VA1112-6EE46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£497.18

EACH

Datasheet
3VA1112-6EE42-0AA0
3VA1112-6EE42-0AA0
3VA1112-6EE42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£479.77

EACH

Datasheet
3VA1112-6EE36-0AC0
3VA1112-6EE36-0AC0
3VA1112-6EE36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp connection circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In clamp 2 AUXILIARY SWITCH CHANGEOVER H

£471.14

EACH

Datasheet
3VA1112-6EE36-0AA0
3VA1112-6EE36-0AA0
3VA1112-6EE36-0AA0MCCB_IEC_FS160_125A_3P_70KA_TM_ ATFM

£330.32

EACH

Catalogue
Datasheet
3VA1112-6EE32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In nut keeper kit

£292.01

EACH

Datasheet
3VA1112-6ED46-0AA0
3VA1112-6ED46-0AA0
3VA1112-6ED46-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected clamp connection

£487.19

EACH

Datasheet
3VA1112-5MH36-0CC0
3VA1112-5MH36-0CC0
3VA1112-5MH36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-6ED42-0AA0
3VA1112-6ED42-0AA0
3VA1112-6ED42-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

£469.77

EACH

Datasheet
3VA1112-6ED32-0AA0
3VA1112-6ED32-0AA0
3VA1112-6ED32-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

£285.75

EACH

Datasheet
3VA1112-5MH36-0KH0
3VA1112-5MH36-0KH0
3VA1112-5MH36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5MH36-0KC0
3VA1112-5MH36-0KC0
3VA1112-5MH36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5MH36-0KA0
3VA1112-5MH36-0KA0
3VA1112-5MH36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC

£485.32

EACH

Datasheet
3VA1112-5MH36-0JH0
3VA1112-5MH36-0JH0
3VA1112-5MH36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5MH36-0JC0
3VA1112-5MH36-0JC0
3VA1112-5MH36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5MH36-0JA0
3VA1112-5MH36-0JA0
3VA1112-5MH36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£485.32

EACH

Datasheet
3VA1112-5MH36-0HH0
3VA1112-5MH36-0HH0
3VA1112-5MH36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£540.10

EACH

Datasheet
3VA1112-5MH36-0HC0
3VA1112-5MH36-0HC0
3VA1112-5MH36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£521.39

EACH

Datasheet
3VA1112-5MH36-0HA0
3VA1112-5MH36-0HA0
3VA1112-5MH36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz

£485.32

EACH

Datasheet
3VA1112-5MH36-0DH0
3VA1112-5MH36-0DH0
3VA1112-5MH36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.07

EACH

Datasheet
3VA1112-5MH36-0DC0
3VA1112-5MH36-0DC0
3VA1112-5MH36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£540.73

EACH

Datasheet
3VA1112-5MH36-0DA0
3VA1112-5MH36-0DA0
3VA1112-5MH36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£504.66

EACH

Datasheet
3VA1112-6ED36-0AA0
3VA1112-6ED36-0AA0
3VA1112-6ED36-0AA0MCCB_IEC_FS160_125A_3P_70KA_TM_ FTFM

£314.55

EACH

Catalogue
Datasheet
3VA1112-6MH32-0AE0
3VA1112-6MH32-0AE0
3VA1112-6MH32-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 4 auxiliary switches HQ

£513.02

EACH

Datasheet
3VA1112-6MH32-0AG0
3VA1112-6MH32-0AG0
3VA1112-6MH32-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 1 auxiliary switch HP 1 trip alarm switch HP

£495.61

EACH

Datasheet
3VA1112-6MH36-0BA0
3VA1112-6MH36-0BA0
3VA1112-6MH36-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC

£541.38

EACH

Datasheet
3VA1112-6MH36-0AH0
3VA1112-6MH36-0AH0
3VA1112-6MH36-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HQ 1 trip alarm switch HQ

£511.73

EACH

Datasheet
3VA1112-6MH36-0AG0
3VA1112-6MH36-0AG0
3VA1112-6MH36-0AG0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 1 auxiliary switch HP 1 trip alarm switch HP

£511.73

EACH

Datasheet
3VA1112-6MH36-0AF0
3VA1112-6MH36-0AF0
3VA1112-6MH36-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switch HQ

£494.33

EACH

Datasheet
3VA1112-6MH36-0AE0
3VA1112-6MH36-0AE0
3VA1112-6MH36-0AE0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 4 auxiliary switches HQ

£530.43

EACH

Datasheet
3VA1112-6MH36-0AD0
3VA1112-6MH36-0AD0
3VA1112-6MH36-0AD0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 3 auxiliary switches HQ

£511.73

EACH

Datasheet
3VA1112-6MH36-0AC0
3VA1112-6MH36-0AC0
3VA1112-6MH36-0AC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HQ

£494.33

EACH

Datasheet
3VA1112-6MH36-0AB0
3VA1112-6MH36-0AB0
3VA1112-6MH36-0AB0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection 2 auxiliary switches HP

£511.73

EACH

Datasheet
3VA1112-6MH36-0AA0
3VA1112-6MH36-0AA0
3VA1112-6MH36-0AA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=7...16 x In clamp connection

£470.91

EACH

Datasheet
3VA1112-6MH32-0KH0
3VA1112-6MH32-0KH0
3VA1112-6MH32-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6MH32-0KC0
3VA1112-6MH32-0KC0
3VA1112-6MH32-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6MH32-0KA0
3VA1112-6MH32-0KA0
3VA1112-6MH32-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 220-250 V DC; 208-277 V AC

£505.94

EACH

Datasheet
3VA1112-6MH32-0JH0
3VA1112-6MH32-0JH0
3VA1112-6MH32-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6MH36-0BC0
3VA1112-6MH36-0BC0
3VA1112-6MH36-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6MH32-0JC0
3VA1112-6MH32-0JC0
3VA1112-6MH32-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6MH32-0HH0
3VA1112-6MH32-0HH0
3VA1112-6MH32-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£560.72

EACH

Datasheet
3VA1112-6MH32-0HC0
3VA1112-6MH32-0HC0
3VA1112-6MH32-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£541.38

EACH

Datasheet
3VA1112-6MH32-0HA0
3VA1112-6MH32-0HA0
3VA1112-6MH32-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz

£505.94

EACH

Datasheet
3VA1112-6MH32-0DH0
3VA1112-6MH32-0DH0
3VA1112-6MH32-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6MH32-0DC0
3VA1112-6MH32-0DC0
3VA1112-6MH32-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6MH32-0DA0
3VA1112-6MH32-0DA0
3VA1112-6MH32-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz

£524.62

EACH

Datasheet
3VA1112-6MH32-0CH0
3VA1112-6MH32-0CH0
3VA1112-6MH32-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6MH32-0CC0
3VA1112-6MH32-0CC0
3VA1112-6MH32-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6MH32-0CA0
3VA1112-6MH32-0CA0
3VA1112-6MH32-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/60Hz

£524.62

EACH

Datasheet
3VA1112-6MH32-0BH0
3VA1112-6MH32-0BH0
3VA1112-6MH32-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£580.05

EACH

Datasheet
3VA1112-6MH32-0BC0
3VA1112-6MH32-0BC0
3VA1112-6MH32-0BC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ

£561.37

EACH

Datasheet
3VA1112-6MH32-0BA0
3VA1112-6MH32-0BA0
3VA1112-6MH32-0BA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit undervoltage release (UVR) 24V DC

£524.62

EACH

Datasheet
3VA1112-6MH32-0AH0
3VA1112-6MH32-0AH0
3VA1112-6MH32-0AH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ

£495.61

EACH

Datasheet
3VA1112-6MH32-0JA0
3VA1112-6MH32-0JA0
3VA1112-6MH32-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz

£505.94

EACH

Datasheet
3VA1112-6MH32-0AF0
3VA1112-6MH32-0AF0
3VA1112-6MH32-0AF0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In nut keeper kit 1 auxiliary switch HQ 1 trip alarm switch HQ

£476.28

EACH

Datasheet
3VA1112-6MH36-0BH0
3VA1112-6MH36-0BH0
3VA1112-6MH36-0BH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
3VA1112-6MH36-0CC0
3VA1112-6MH36-0CC0
3VA1112-6MH36-0CC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6MH36-0CA0
3VA1112-6MH36-0CA0
3VA1112-6MH36-0CA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz

£541.38

EACH

Datasheet
3VA1112-6MH36-0KH0
3VA1112-6MH36-0KH0
3VA1112-6MH36-0KH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6MH36-0KC0
3VA1112-6MH36-0KC0
3VA1112-6MH36-0KC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6MH36-0KA0
3VA1112-6MH36-0KA0
3VA1112-6MH36-0KA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 220-250 V DC; 208-277 V AC

£522.05

EACH

Datasheet
3VA1112-6MH36-0JH0
3VA1112-6MH36-0JH0
3VA1112-6MH36-0JH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6MH36-0JC0
3VA1112-6MH36-0JC0
3VA1112-6MH36-0JC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6MH36-0JA0
3VA1112-6MH36-0JA0
3VA1112-6MH36-0JA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz

£522.05

EACH

Datasheet
3VA1112-6MH36-0HH0
3VA1112-6MH36-0HH0
3VA1112-6MH36-0HH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£578.11

EACH

Datasheet
3VA1112-6MH36-0HC0
3VA1112-6MH36-0HC0
3VA1112-6MH36-0HC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz 2 auxiliary switches HQ

£559.44

EACH

Datasheet
3VA1112-6MH36-0HA0
3VA1112-6MH36-0HA0
3VA1112-6MH36-0HA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz

£522.05

EACH

Datasheet
3VA1112-6MH36-0DH0
3VA1112-6MH36-0DH0
3VA1112-6MH36-0DH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
3VA1112-6MH36-0DC0
3VA1112-6MH36-0DC0
3VA1112-6MH36-0DC0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz 2 auxiliary switches HQ

£578.76

EACH

Datasheet
3VA1112-6MH36-0DA0
3VA1112-6MH36-0DA0
3VA1112-6MH36-0DA0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 208-230V AC 50/60Hz

£541.38

EACH

Datasheet
3VA1112-6MH36-0CH0
3VA1112-6MH36-0CH0
3VA1112-6MH36-0CH0circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=125A without overload protection short-circuit protection Ii=5...15 x In clamp connection undervoltage release (UVR) 120-127V AC 50/60Hz 2 auxiliary switches HQ 1 trip alarm switch HQ

£596.17

EACH

Datasheet
Register NowNavigation
  • Home
  • Contact Us
  • Price Downloads
  • Desktop Estimating
  • Online Estimating
  • About Us
  • Catalogues
  • Favourites
  • Desktop Downloads
  • News
Register NowRegister Now

Join Electrika today to gain access to many great features including trade prices, downloads and estimating tools.

Register
Electrika Logo

© Copyright 2025 Electrika Ltd

Privacy & Cookie Policy

Terms of Use

Powered By OneTimePIM